journal article·2007-11

VRLA Ultrabattery for high-rate partial-state-of-charge operation

L.T. Lam, R. Louey, N.P. Haigh, O.V. Lim, D.G. Vella, C.G. Phyland, L.H. Vu, J. Furukawa, T. Takada, D. Monma, T. Kano

Journal of Power Sources· Volume 174· Issue 1
Publisher page

Abstract

Abstract The objective of this study is to produce and test the hybrid valve-regulated Ultrabattery designed specifically for hybrid-electric vehicle duty, i.e., high-rate partial-state-of-charge operation. The Ultrabattery developed by CSIRO Energy Technology is a hybrid energy-storage device, which combines an asymmetric supercapacitor, and a lead-acid battery in one unit cells, taking the best from both technologies without the need for extra, expensive electronic controls. The capacitor will enhance the power and lifespan of the lead-acid battery as it acts as a buffer during high-rate discharging and charging. Consequently, this hybrid technology is able to provide and absorb charge rapidly during vehicle acceleration and braking. The work programme of this study is divided into two main parts, namely, field trial of prototype Ultrabatteries in a Honda Insight HEV and laboratory tests of prototype batteries. In this paper, the performance of prototype Ultrabatteries under different laboratory tests is reported. The evaluation of Ultrabatteries in terms of initial performance and cycling performance has been conducted at both CSIRO and Furukawa laboratories. The initial performance of prototype Ultrabatteries, such as capacity, power, cold cranking and self-discharge has been evaluated based upon the US FreedomCAR Battery Test Manual (DOE/ID-11069, October 2003). Results show that the Ultrabatteries meet, or exceed, respective targets of power, available energy, cold cranking and self-discharge set for both minimum and maximum power-assist HEVs. The cycling performance of prototype Ultrabatteries has been evaluated using: (i) simplified discharge and charge profile to simulate the driving conditions of micro-HEV; (ii) 42-V profile to simulate the driving conditions of mild-HEV and (iii) EUCAR and RHOLAB profiles to simulate the driving conditions of medium-HEV. For comparison purposes, nickel–metal-hydride (Ni–MH) cells, which are presently used in the Honda Insight HEV, have also been subjected to some of the above profiles (i.e., simplified discharge and charge profile and EUCAR profile). Although the Ultrabattery and a Ni–MH cell under EUCAR test profile are still on cycling, the outcomes to date show that the performance of these batteries and cells has been at least four times longer than that of the state-of-the art lead-acid cells or batteries. Excitingly, the performance of Ultrabatteries is proven to be comparable with that of the Ni–MH cells.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Advanced Battery Technologies Research · Supercapacitor Materials and Fabrication · Electric and Hybrid Vehicle Technologies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (20)

Show source-provided references
1. L.T. Lam, C.G. Phyland, D.A.J. Rand, A.J. Urban, ALABC Project C2.0, Novel Technique to Ensure Battery Reliability in 42-V PowerNets for New-generation Automobiles, Progress Report: August 2001–January 2002, CSIRO Energy Technology, Investigation Report ET/IR480R, March 2002, 19 pp.
2. L.T. Lam, N.P. Haigh, C.G. Phyland, D.A.J. Rand, A.J. Urban, ALABC Project C 2.0, Novel Technique to Ensure Battery Reliability in 42-V PowerNets for New-generation Automobiles, Final Report: August 2001–November 2002, CSIRO Energy Technology, Investigation Report ET/IR561R, December 2002, 39 pp.
3. L.T. Lam, N.P. Haigh, C.G. Phyland, T.D. Huynh, D.A.J. Rand, ALABC Project C 2.0, Novel Technique to Ensure Battery Reliability in 42-V PowerNets for New-generation Automobiles, Extended Report: January–April 2003, CSIRO Energy Technology, Investigation Report ET/IR604R, May 2003, 23 pp.
4. A.F. Hollenkamp, W.G.A. Baldsing, S. Lau, O.V. Lim, R.H. Newnham, D.A.J. Rand, J.M. Rosalie, D.G. Vella, L.H. Vu, ALABC Project N1.2, Overcoming Negative-plate Capacity Loss in VRLA Batteries Cycled under Partial State-of-Charge Duty, Final Report: July 2000–June 2002, CSIRO Energy Technology, Investigation Report ET/IR491R, June 2002, 47 pp.
5. Lam · J. Power Sources · 2005 · 144 · 55210.1016/j.jpowsour.2004.11.028 ↗
6. Lam · J. Power Sources · 2004 · 133 · 12610.1016/j.jpowsour.2003.11.048 ↗
7. Nakamura · J. Power Sources · 1996 · 59 · 15310.1016/0378-7753(95)02317-8 ↗
8. Shiomi · J. Power Sources · 1997 · 64 · 14710.1016/S0378-7753(96)02515-3 ↗
9. K. Honbo, E. Hoshi, A. Miura, T. Hiraswa, In-situ Analyses of Negative Electrodes for Lead-Acid Batteries on Charge–Discharge Reaction by Atomic Force Microscopy, Shin-Kobe Technical Report No. 12, February 2002, pp. 3–10.
10. R.H. Newnham, W.G.A. Baldsing, A.F. Hollenkamp, O.V. Lim, C.G. Phyland, D.A.J. Rand, J.M. Rosalie, D.G. Vella, Advancement of Valve-Regulated Lead-Acid Battery Technology for Hybrid-Electric and Electric Vehicles, ALABC Project C/N 1.1, Final Report: July 2000–June 2002, CSIRO Energy Technology, Investigation Report ET/IR520R, August 2002, 44 pp.
11. L.T. Lam, N.P. Haigh, O.V. Lim, T. Lwin, C.G. Phyland, D.G. Vella, ALABC Project TE-1, Influence of Trace Elements, Plate-Processing Conditions, and Electrolyte Concentration on the Performance of Valve-Regulated Lead-Acid Batteries at High Temperatures and Under High-Rate Partial-State-of-Charge Operation, Final Report: August 2003–July 2005, CSIRO Energy Technology, Investigation Report ET/IR809R, July 2005, 43 pp.
12. Australian Patent Application No. 2003905086.
13. International Patent Application No. PCT/AU2004/001262.
14. Lam · J. Power Sources · 2006 · 158 · 114010.1016/j.jpowsour.2006.03.022 ↗
15. US FreedomCAR Battery Test Manual, DOE/ID-11069, October 2003.
16. T. Noda, K. Hata, K. Yamanaka, M. Tsubota, Paper Presented at the Ninth Asian Battery Conference, Bali, Indonesia, September, 2001.
17. L.T. Lam, R. Louey, N.P. Haigh, O.V. Lim, D.G. Vella, C.G. Phyland, L.H. Vu, ALABC Project DP 1.1, Production and Test of Hybrid VRLA Ultrabattery Designed Specifically for High-Rate Partial-State-of-Charge Operation, Progress Report: August 2006–October 2006, CSIRO Energy Technology, Investigation Report ET/IR911R, October 2006, 38 pp.
18. Trinidad · J. Power Sources · 2003 · 116 · 12810.1016/S0378-7753(02)00716-4 ↗
19. Cooper · J. Power Sources · 2004 · 133 · 11610.1016/j.jpowsour.2003.11.069 ↗
20. Cooper · J. Power Sources · 2005 · 144 · 38510.1016/j.jpowsour.2004.10.034 ↗