journal article·2011-02

Lead-acid batteries in micro-hybrid applications. Part II. Test proposal

S. Schaeck, A.O. Stoermer, J. Albers, D. Weirather-Koestner, H. Kabza

Journal of Power Sources· Volume 196· Issue 3
Publisher page

Abstract

Abstract In the first part of this work [1] selected key parameters for applying lead-acid (LA) batteries in micro-hybrid power systems (MHPS) were investigated. Main results are integrated in an accelerated, comprehensive test proposal presented here. The test proposal aims at a realistic representation of the pSoC operation regime, which is described in Refs. [1] , [6] . The test is designed to be sensitive with respect to dynamic charge acceptance (DCA) at partially discharged state (critical for regenerative braking) and the internal resistance at high-rate discharge (critical for idling stop applications). First results are presented for up-to-date valve-regulated LA batteries with absorbent glass mat (AGM) separators. The batteries are close to the limits of the first proposal of pass/fail-criteria. Also flooded batteries were tested; the first out of ten units failed already.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Wireless Sensor Networks for Data Analysis · Advanced Battery Technologies Research · Engine and Fuel Emissions

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (12)

Show source-provided references
1. Schaeck · J. Power Sources · 2011 · 196 · 154110.1016/j.jpowsour.2010.08.077 ↗
2. DIN EN 50342-1, Lead-acid starter batteries – General requirements and methods of test, November 2006.
3. 1980
4. BMW Group, Wartungsfreie PKW-Starterbatterien (Anforderungen, Prüfungen), 2000.
5. J. Albers, E. Meißner, S. Shirazi, Presented at 12th European Lead Battery Conference (12ELBC), Istanbul, 21–24 September, J. Power Sources, (2010), submitted for publication.
6. Schaeck · J. Power Sources · 2009 · 190 · 17310.1016/j.jpowsour.2008.10.061 ↗
7. S. Schaeck, T. Karspeck, C. Ott, D. Weirather-Koestner, A.O. Stoermer, J. Power Sources (2010), in press, doi:10.1016/j.jpowsour.2010.08.101.10.1016/j.jpowsour.2010.08.101 ↗
8. S. Schaeck, T. Karspeck, C. Ott, M. Weckler, A.O. Stoermer, J. Power Sources, accepted manuscript.
9. Sawai · J. Power Sources · 2007 · 174 · 5410.1016/j.jpowsour.2007.04.033 ↗
10. Battery Association of Japan. Start-up lead-acid battery for idling-stop cars. Test method, performance, dimensions and marking. Standard SBA A0101, 2005.
11. Takeuchi · J. Power Sources · 2009 · 189 · 119010.1016/j.jpowsour.2009.01.022 ↗
12. Kondo · 2009