Abstract

In actual size of polymer electrolyte fuel cell stack with heat management of cooling water, relative humidity distribution was calculated under various kinds of operating conditions and various shapes of gas channel with numerical analysis. And the optimal separator shape and the optimal flow pattern of gas and cooling water that make the relative humidity higher and more uniform and that lead to the improvement of cell durability were examined under each operating condition. As a result, the effects of humidify temperature, the temperature of cooling water at an outlet and the average current density on humidity distribution which was affected by vapor concentration and gas temperature were examined and it was found that the optimal combination of flow pattern of gas and cooling water was the same under each operating condition. As regards the operating condition in this paper, the relative humidity is the highest and the most uniform in the following cases: gas flow pattern is counter, the cooling water is synchronized with cathode gas flow and the ordinary serpentine separator with 1.0 mm depth channels is used in cathode and anode sides. However, it is found that it is possible to occur the flooding in such cases.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Fuel Cells and Related Materials · Electrocatalysts for Energy Conversion · Advancements in Solid Oxide Fuel Cells

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (12)

Show source-provided references
1. Degradation study of MEA for PEMFC under low humidity conditions
2. Chemical degradation of Nafion™ membranes
3. LaConti · 2003 · vol. 3
4. A PEM fuel cell for combined measurement of current and temperature distribution, and flow field flooding10.1016/j.jpowsour.2003.11.081 ↗
5. Relationship between pressure drop and cell resistance as a diagnostic tool for PEM fuel cells10.1016/j.jpowsour.2004.08.055 ↗
6. Diagnostic tools for liquid water in PEM fuel cells10.1016/j.jpowsour.2004.11.036 ↗
7. Water behavior in serpentine micro-channel for proton exchange membrane fuel cell cathode10.1016/j.jpowsour.2005.02.075 ↗
8. Two-phase modeling and flooding prediction of polymer electrolyte fuel cells10.1149/1.1850339 ↗
9. Liquid water removal from a polymer electrolyte fuel cell10.1149/1.2138675 ↗
10. G. Inoue, T. Yoshimoto, Y. Matsukuma, M. Minemoto, H. Itoh, S. Tsurumaki, Numerical analysis of relative humidity distribution in polymer electrolyte fuel cell stack including cooling water, J. Power Sources (in press).
11. Effect of gas channel depth on current density distribution of polymer electrolyte fuel cell by numerical analysis including gas flow through gas diffusion layer10.1016/j.jpowsour.2005.08.004 ↗
12. Examination of optimal separator shape of polymer electrolyte fuel cell with numerical analysis including the effect of gas flow through gas diffusion layer10.1016/j.jpowsour.2005.08.003 ↗