Siloxane-pHEMA hybrid coatings with the addition of calcium chloride and calcium sulfate during the synthesis of the material were produced by the sol–gel method and deposited on Ti-6Al-4V alloy by dip-coating. The structural characteristics of the hybrid materials were analyzed by means of Nuclear Magnetic Resonance and Small/Wide Angle X-ray Scattering; their morphological properties were analyzed by means of Scanning Electron Microscopy and Atomic Force Microscopy. The electrochemical behavior and resistance to corrosion of hybrid coatings with and without addition of calcium salts were analyzed by means of Electrochemical Impedance Spectroscopy. The results showed that the coatings were homogeneous due to the rigid silica network formed during the polymerization, hydrolysis and reactions of condensation. In the sample, into which calcium sulfate was added, there was a decrease of the average roughness value (15.0 nm), while exhibiting regular topography and good adhesion to the substrate, suggesting that this coating has appealing characteristics for anticorrosive applications. Electrochemical tests in simulated body fluid (that underwent simulation) showed that the coatings with hybrid system showed better properties of a barrier with up to 96 h of immersion, in comparison to samples without coating. Therefore, these coatings showed promising features suitable for anticorrosion applications in biomaterials. Moreover, due to the addition of calcium sulfate, coatings made it possible to convey a good balance between biological and anticorrosion properties and, which in itself allows biocompatibility without compromising resistance to corrosion.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Corrosion Behavior and Inhibition · Hydrogen embrittlement and corrosion behaviors in metals · Orthopaedic implants and arthroplasty

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (36)

Show source-provided references
1. Sadiq TO, Siti N, Idris J (2018) A study of strontium-doped calcium phosphate coated On Ti6Al4V using microwave energy. J Bio Tribo Corros, 4. https://doi.org/10.1007/s40735-018-0149-910.1007/s40735-018-0149-9 ↗
2. Lugo VR, Castaño VM, Rubio-rosas E (2016) Biomimetic growth of hydroxylapatite on SiO2–PMMA hybrid coatings. Mater Lett. https://doi.org/10.1016/j.matlet.2016.08.06810.1016/j.matlet.2016.08.068 ↗
3. Rylska D, Sokołowski G, Sokołowski J, Łukomska-Szymańska M (2017) Chemical passivation as a method of improving the electrochemical corrosion resistance of Co-Cr-based dental alloy. Acta Bioeng Biomech. https://doi.org/10.5277/ABB-00600-2016-0410.5277/ABB-00600-2016-04 ↗
4. Catauro M, Bollino F, Giovanardi R, Veronesi P (2016) Modification of Ti6Al4V implant surfaces by biocompatible TiO2/PCL hybrid layers prepared via sol-gel dip coating: structural characterization, mechanical and corrosion behavior. Mater Sci Eng C. https://doi.org/10.1016/j.msec.2016.12.04610.1016/j.msec.2016.12.046 ↗
5. Muresan LM (2015) Corrosion protective coatings for Ti and Ti alloys used for biomedical implants. Intell Coat Corros Control. https://doi.org/10.1016/B978-0-12-411467-8.00017-910.1016/B978-0-12-411467-8.00017-9 ↗
6. Izquierdo-Barba I, Vallet-Regi M, Rojo JM, Blanco E, Esquivias L (2003) The role of precursor concentration on the characteristics of SiO2-CaO films. J Sol Gel Sci Technol. https://doi.org/10.1023/A:102074790039910.1023/A:1020747900399 ↗
7. Durán A, Conde A, Coedo AG, Dorado T, García C, Ceré S (2004) Sol-gel coatings for protective and bioactive functionalisation of metals used in orthopaedic devices. J Mater Chem. https://doi.org/10.1039/B401370K10.1039/B401370K ↗
8. Torres Y, Sarria P, Gotor FJ, Gutiérrez E, Peon E, Beltrán AM, González JE (2018) Surface modification of Ti-6Al-4V alloys manufactured by selective laser melting: microstructural and tribo-mechanical characterization. Surf Coat Tech. https://doi.org/10.1016/j.surfcoat.2018.05.01510.1016/j.surfcoat.2018.05.015 ↗
9. Suzana AF, Ferreira EA, Benedetti AV, Carvalho HWP, Santilli CV, Pulcinelli SH (2016) Corrosion protection of chromium-coated steel by hybrid sol-gel coatings. Surf Coat Tech. https://doi.org/10.1016/j.surfcoat.2016.04.07510.1016/j.surfcoat.2016.04.075 ↗
10. Tiwari I, Mahanwar PA (2018) Polyacrylate/silica hybrid materials: a step towards multifunctional properties. J Disper Sci Technol. https://doi.org/10.1080/01932691.2018.148927610.1080/01932691.2018.1489276 ↗
11. Schiraldi C, D’Agostino A, Oliva A, Flamma F, De Rosa A, Apicella A, Aversa R, De Rosa M (2004) Development of hybrid materials based on hydroxyethylmethacrylate as supports for improving cell adhesion and proliferation. Biomaterials. https://doi.org/10.1016/j.biomaterials.2003.10.05910.1016/j.biomaterials.2003.10.059 ↗
12. Ravarian R, Zhong X, Barbeck M, Ghanaati S, Kirkpatrick CJ, Murphy CM, Schindeler A, Chrzanowski W, Dehghani F (2013) Nanoscale chemical interaction enhances the physical properties of bioglass composites. ACS Nano. https://doi.org/10.1021/nn402157n10.1021/nn402157n ↗
13. Asri RIM, Harun WSW, Samykano M, Lah NAC, Ghani SAC, Tarlochan F, Raza MR (2017) Corrosion and surface modification on biocompatible metals. Mater Sci Eng. https://doi.org/10.1016/j.msec.2017.04.10210.1016/j.msec.2017.04.102 ↗
14. Valliant EM, Jones JR (2011) Softening bioactive glass for bone regeneration: sol-gel hybrid materials. Soft Matter. https://doi.org/10.1039/c0sm01348j10.1039/c0sm01348j ↗
15. Poologasundarampillai G, Yu B, Tsigkou O, Wang D, Romer F, Bhakhri V, Giuliani F, Stevens MM, McPhail DS, Smith ME, Hanna JV, Jones JR (2014) Poly(γ-glutamic acid)/silica hybrids with calcium incorporated in the silica network by use of a calcium alkoxide precursor. Chem Eur J. https://doi.org/10.1002/chem.20130401310.1002/chem.201304013 ↗
16. Gao C, Huo S, Li X, You X, Zhang Y, Gao J (2007) Characteristics of calcium sulfate/gelatin co mposite biomaterials for bone repair. J Biomater Sci Polym Ed. https://doi.org/10.1163/15685620778136771010.1163/156856207781367710 ↗
17. ASTM F136-13 (2013) Standard specification for wrought titanium-6aluminum4aanadium ELI (extra low interstitial) alloy for surgical implant applications (UNS R56401) (70–74). ASTM International, West Conshohocken, PA
18. Santana JA, Kunst SR, Oliveira CT, Bastos AA, Ferreira MGS, Sarmento VHV (2020) PMMA-SiO2 organic-inorganic hybrid coating application to Ti-6Al-4V alloy prepared through the sol-gel method. J Braz Chem Soc 31(2):409–420. https://doi.org/10.21577/0103-5053.2019019810.21577/0103-5053.20190198 ↗
19. Hammouda B (2010) A new Guini er–Porod model. J Appl Crystallogr. https://doi.org/10.1107/S002188981001577310.1107/S0021889810015773 ↗
20. Suegama PH, Sarmento VHV, Montemor MF, Benedetti AV, Melo HG, Aoki IV, Santilli CV (2010) Effect of cerium (IV) ions on the anticorrosion properties of siloxane-poly (methyl methacrylate) based film applied on tin coated steel. Electrochim Acta. https://doi.org/10.1016/j.electacta.2010.04.00210.1016/j.electacta.2010.04.002 ↗
21. Kunst SR, Beltrami LVR, Cardoso HRP, Veja MRO, Baldin EKK, Menezes TL, Malfatti CF (2014) Effect o f curing temperature and architectural (monolayer and bilayer) of hybrid films modified with polyethylene glycol for the corrosion protection on tinplate. Mater Res. https://doi.org/10.1590/1516-1439.28461410.1590/1516-1439.284614 ↗
22. Criado M, Sobrados I, Sanz J (2014) Polymerization of hybrid organic–inorganic materials from several silicon compounds followed by TGA/DTA, FTIR and NMR techniques. Prog Org Coat. https://doi.org/10.1016/j.porgcoat.2014.01.01910.1016/j.porgcoat.2014.01.019 ↗
23. Torrico RFAO, Harb SV, Trentin A, Uvida MC, Pulcinelli SH, Santilli CV, Hammer P (2018) Structure and properties of epoxy-siloxane-silica nanocomposite coatings for corrosion protection. J Colloid Inter Sci. https://doi.org/10.1016/j.jcis.2017.11.06910.1016/j.jcis.2017.11.069 ↗
24. Souza JCM, Barbosa SL, Ariza EA, Henriques M, Teughels W, Ponthiaux P, Celis JP, Rocha LA (2015) How do titanium and Ti6Al4V corrode in fl uoridated medium as found in the oral cavity? An in vitro study. Mat Sci Eng C Mater. https://doi.org/10.1016/j.msec.2014.11.05510.1016/j.msec.2014.11.055 ↗
25. Kunst SR, Cardoso HRP, Oliveira CT, Santana JA, Sarmento VHV, Muller IL, Malfatti CF (2014) Corrosion resistance of siloxane–poly(methyl methacrylate) hybrid films modified with acetic acid on tin plate substrates: influence of tetraethoxysilane addition. Appl Surf Sci. https://doi.org/10.1016/j.apsusc.2013.09.18210.1016/j.apsusc.2013.09.182 ↗
26. Hansal WEG, Hansal S, Pölzler M, Kornherr A, Zifferer G, Nauer GE (2006) Investigation of polysiloxane coatings as corrosion inhibitors of zinc surfaces. Surf Coat Tech. https://doi.org/10.1016/j.surfcoat.2005.01.04910.1016/j.surfcoat.2005.01.049 ↗
27. Marino CEB, Mascaro LH (2011) Electrochemical tests to evaluate the stability of the anodic films on dental implants. J Electrochem. https://doi.org/10.4061/2011/57450210.4061/2011/574502 ↗
28. Salvador DG, Marcolin P, Beltrami LVR, Brandalise RN, Kunst SR (2017) Influence of the pretreatment and curing of alkoxysilanes on the protection of the titanium–aluminum–vanadium alloy. J Appl Polym Sci. https://doi.org/10.1002/app.4547010.1002/app.45470 ↗
29. Wieland M, Chehroudi B, Textor M, Brunette DM (2002) Use of Ti-coated replicas to investigate the effects on fibroblast shape of surfaces with varying roughness and constant chemical composition. J Biomed Mater. https://doi.org/10.1002/jbm.1005910.1002/jbm.10059 ↗
30. Pfeiffer F, Herzog B, Kern D, Scheideler L, Geis-Gerstorferc J, Wolburga H (2003) Cell reactions to microstructured implant surfaces Microelectron Eng 67–68:913–922. https://doi.org/10.1016/S0167-9317(03)00154-010.1016/S0167-9317(03)00154-0 ↗
31. Li J, Liu X (2015) Chemical surface modification of metallic biomaterials. Surf Coat Modif Met Biomater. https://doi.org/10.1016/B978-1-78242-303-4.00005-310.1016/B978-1-78242-303-4.00005-3 ↗
32. Heakal FE, Ghoneim AA, Mogoda AS, Awad K (2011) Electrochemical behaviour of Ti-6Al-4V alloy and Ti in azide and halide solutions. Corros Sci. https://doi.org/10.1016/j.corsci.2011.05.00310.1016/j.corsci.2011.05.003 ↗
33. El Hadad AA, Peón E, García-Galván FR, Barranco V, Parra J, Jiménez-Morales A, Galván JC (2017) Biocompatibility and corrosion protection behaviour of hydroxyapatite sol-gel-derived coatings on Ti6Al4V alloy. Mater Lett. https://doi.org/10.3390/ma1002009410.3390/ma10020094 ↗
34. Kunst SR, Cardoso HRP, Oliveira CT, Filho CIS, Sarmento VHV, Menezes TL, Muller IL, Malfatti CF (2013) Influence of tetraethoxysilane addition in siloxane-poly(methyl methacrylate) hybrid films applied on galvanized steel. Int J Electrochem Sci 8:11984–1200410.1016/S1452-3981(23)13237-8 ↗
35. Bossard C, Granel H, Jallot E, Montouillout V, Fayon F, Soulié J, Drouet C, Wittrant Y, Lao J (2019) Mechanism of calcium incorporation inside sol−gel silicate bioactive glass and the advantage of using Ca(OH)2 over other calcium sources. ACS Biomater Sci Eng 5(11):5906–5915. https://doi.org/10.1021/acsbiomaterials.9b0124510.1021/acsbiomaterials.9b01245 ↗
36. Cambon JB, Esteban J, Ansart F, Bonino JP, Turq V, Santagneli SH, Santilli CV, Pulcinelli SH (2012) Effect of cerium on structure modifications of a hybrid sol–gel coating, its mechanical properties and anti-corrosion behaviour. Mater Res Bull. https://doi.org/10.1016/j.materresbull.2012.08.03410.1016/j.materresbull.2012.08.034 ↗