Moisture Meter Calibrations for Untreated and ACQ-Treated Southern Yellow Pine Lumber and Plywood
Source abstract
Abstract
Abstract This study investigates the effects of alkaline copper quaternary (ACQ) preservative treatment and of plywood glue lines on resistance-based moisture content (MC) measurements. Moisture meter readings using stainless steel screws as electrodes were acquired over a range of moisture conditions in Southern Yellow Pine (SYP) lumber and plywood. Calibration equations are presented for predicting gravimetric MC from meter readings taken in SYP lumber and SYP plywood with or without ACQ treatment. These corrections assume that the meter has been set for SYP. Correlation equations are also presented for directly relating resistance to gravimetric MC, which may be useful for automated data collection systems employed in monitoring moisture levels in buildings. The conductance of SYP lumber was raised by treatment with ACQ, particularly at higher moisture contents, but was unaffected by vacuum-pressure treatment with water. The conductance of untreated SYP plywood, measured with electrodes penetrating the glue lines, exceeded that of untreated SYP lumber. The conductance of SYP plywood was lowered by treatment with ACQ, by vacuum-pressure soaking with water, and by exposure to rain. We suggest that electrolytes in the plywood glue lines increase the conductance of untreated plywood relative to that of untreated lumber, and that the concentration of these electrolytes is lowered by the (aqueous) preservative treatment process, thereby lowering the conductance of these high-conductance pathways.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Wood Treatment and Properties · Hygrothermal properties of building materials · Postharvest Quality and Shelf Life Management
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Forest Products Laboratory, U.S. Forest Service 1 General Engineer , , 1 Gifford Pinchot Dr., Madison, WI53726, US .
Forest Products Laboratory, U.S. Forest Service 2 Research Physical Scientist , , 1 Gifford Pinchot Dr., Madison, WI53726, US .
Forest Products Laboratory, U.S. Forest Service 3 Research Forest Products Technologist , , 1 Gifford Pinchot Dr., Madison, WI53726, US .
References (25)
Show source-provided references
1. James, W. L. , “Electric moisture meters for wood,” General Technical Report No. FPL-GTR-6, U.S. Dept. of Agriculture, Forest Service, Forest Products Laboratory, Madison, WI, 1988, http://www.fpl.fs.fed.us/documnts/fplgtr/fplgtr06.pdf (Last accessed 28 March 2011).
2. Glass, S. V., and Carll, C. G., “Moisture meter calibration for untreated and ACQ-treated southern yellow pine plywood,” Research Note No. FPL-RN-0312, U.S. Dept. of Agriculture, Forest Service, Forest Products Laboratory, Madison, WI, 2009, http://www.fpl.fs.fed.us/documnts/fplrn/fpl_rn312.pdf (Last accessed 28 March 2011).10.2737/FPL-RN-312 ↗
3. Effect of Cladding Systems on Moisture Performance of Wood-Framed Walls in a Mixed-Humid Climate
4. Case Study: Performance of a House Built on a Treated Wood Foundation System in a Cold Climate
5. Calibration of moisture-meter readings for Douglas-fir plywood
6. Effect of plywood glue lines on the accuracy of moisture-meter indications
7. Simpson, I., Riley, S., and Ball, R., “Moisture Meter Correction Figures for J-Frame LVL Framing,” New Zealand Forest Research Institute (Scion), Rotorua, New Zealand, 2009, http://www.jnl.co.nz/Shared/Documents/Moisture%20Meter%20Correction%20Figures.pdf (Last accessed 28 March 2011).
8. “Using a Moisture Meter for Flooring Applications FAQ, Question 10: Does the Glue Used in Plywood Affect Meter Accuracy?” http://www.delmhorst.com/popups/floor_faq.html#q10 (Last accessed 28 March 2011).
9. Moisture Performance of Insulated, Raised, Wood-Frame Floors: A Study of Twelve Houses in Southern Louisiana
10. Moisture Meter Corrections for ACQ Treated Pine
11. Kear, G. , “The Influence of Timber Treatment Preservative Systems on the Performance of Commercial Moisture Meters,” BRANZ Study Report No. 161, BRANZ Ltd., Judgeford, New Zealand, 2006, http://www.branz.co.nz/cms_show_download.php?id=41186d854cef8e53621bc4470b8d3322e58f6306 (Last accessed 28 March 2011).
12. Use of Moisture Meters with Treated Wood
13. Lebow, S. T. , “Wood Preservation,” Wood Handbook, General Technical Report No. FPL-GTR-190, Forest Service, Forest Products Laboratory, U.S. Dept. of Agriculture, Madison, WI, 2010, Chapter 15, http://www.fpl.fs.fed.us/documnts/fplgtr/fplgtr190/chapter_15.pdf (Last accessed 28 March 2011).
14. James, W. L. , “Effects of Wood Preservatives on Electric Moisture-Meter Readings,” Research Note No. FPL-0106, U.S. Dept. of Agriculture, Forest Service, Forest Products Laboratory, Madison, WI, 1980, http://www.fpl.fs.fed.us/documnts/fplrn/fplrn106.pdf (Last accessed 28 March 2011).
15. Effect of CCA-C Wood Preservative on Moisture Content Readings by the Electronic Resistance-Type Moisture Meter
16. Humidity Fixed Points of Binary Saturated Aqueous Solutions10.6028/jres.081A.011 ↗
17. Long-Term Monitoring of Timber Moisture Content Below the Fiber Saturation Point Using Wood Resistance Sensors
18. Standard Test Method for Laboratory Standardization and Calibration of Hand-Held Moisture Meters
19. Berthouex · 2002 · 31910.1201/9780367802691 ↗
20. Prediction of Long-Term Leaching Potential of Preservative-Treated Wood by Diffusion Modeling10.1515/HF.2005.095 ↗
21. Zelinka, S. L., and Rammer, D. R., “Review of Test Methods Used to Determine the Corrosion Rate of Metals in Contact with Treated Wood,” General Technical Report No. FPL-GTR-156, U.S. Dept. of Agriculture, Forest Service, Forest Products Laboratory, Madison, WI, 2005, http://www.fpl.fs.fed.us/documnts/fplgtr/fpl_gtr156.pdf (Last accessed 29 March 2011).
22. Lin, R. T. , “A Study of Electrical Conduction in Wood,” Ph.D. Dissertation, State Univ. of New York College of Forestry at Syracuse, 1965.
23. Ion Migration in Wood Verified by Neutron Activation Analysis
24. A Percolation Model for Electrical Conduction in Wood with Implications for Wood-Water Relations
25. The Electrical Resistance of Textile Materials: IV. Theory10.1080/19447025308659737 ↗