Abstract The use of precast concrete panels as a cladding material can provide an economical and attractive method to enclose contemporary buildings. In cold climates, improper detailing or inappropriate construction of precast clad walls can result in widespread water problems due to condensation forming within the wall construction. Condensation may form at the interior of the wall assembly due to inadequate protection against air flow through the wall, such as exfiltration of warm, moist indoor air, or by infiltration of cold outdoor air reaching the interior wall components. The condensation within the wall assembly can also be caused by water vapor diffusion into the wall from the building interior. In addition, inadequate separation and/or insulation between precast panels and adjacent cladding components, such as windows, curtain wall, or metal framing components, can result in surface condensation on these wall elements. The moisture from condensation can cause extensive damage to finish materials, including insulation and gypsum wallboard; can result in corrosion and deterioration of metal components, such as structural connections and metal wall framing; and may result in mold and mildew. This paper will (1) present examples of precast clad building wall construction where significant condensation problems have occurred; (2) discuss typical causes of condensation in precast clad buildings in cold climates; (3) review design considerations to reduce the potential for condensation in new buildings; and (4) present repair methods to address condensation in existing buildings.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Concrete Properties and Behavior · Concrete and Cement Materials Research · Fire effects on concrete materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Klein and Hoffman 1 Senior Associate , , 150 South Wacker Dr., Suite 1900, Chicago, IL60606 .
References (5)
Show source-provided references
1. VanGeem · 2006
2. Precast Panel Wall Assemblies
3. Lemieux · 2010
4. THERM 5.2/WINDOW 5.2 NFRC Simulation Manual. (July 2006). Lawrence Berkeley National Laboratory, Berkely, CA, Program software and user’s manual available at http://windows.lbl.gov/software/therm/therm.html.
5. Odom · 2008