journal article·2017-07-01

Comparative Estimates of Uncertainty in Measurements of Fracture Toughness

S. P. Paruchuru, V. U. Kumar, A. Jain, X. N. Dong

Journal of Testing and Evaluation· Volume 45· Issue 4
Publisher page

Abstract

Abstract Measurement of a stress intensity factor using a compact sandwich specimen involves other material properties such as elastic moduli and Poisson’s ratios of interlayer and holder materials, and therefore it affects uncertainty. No attempt was made in the past to quantify the uncertainty due to the systematic effects involved in the measurement a of stress intensity factor (K) using a compact sandwich specimen and energy release rate (G) by the elastic compliance technique. Analysis of Type-B uncertainty gave comparative estimates of uncertainties in (1) Mode I stress intensity factor obtained from CT test, CS test, and CS test of negligible interlayer thickness (h→0), (2) Mode I energy release rate using elastic compliance (EC) technique, and (3) Indirect stress intensity factor obtained using the relation with energy release rate. Using a set of nominal values of cadaver bone tests of a specimen-size bovine femur and a set of instrument/sensor errors and specimen dimension tolerances, without the consideration of a series of experimental/statistical data, gave estimates of type B uncertainty. The analysis additionally gave percentage contributions of (1) relevant sources of uncertainty namely, caliper, tolerance of specimen dimensions, load cell and displacement sensor, and (2) individual parameters like load, specimen dimensions, and material constants included in the formulae, towards the uncertainty in fracture toughness measures. This study provided an understanding of the role of sensor, instrument, and specimen fabricating machine errors on the tests considered. Proportional variation in uncertainty of different measures of fracture toughness was verified for different sizes of specimens. This study showed that the selection of instruments/sensors of viable error levels would scale down the uncertainty of fracture toughness measures obtained by the CS test, and brought it very close to that of the CT test of the same specimen size, with a difference of less than 0.05 %.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Fatigue and fracture mechanics · Orthopaedic implants and arthroplasty · Engineering Structural Analysis Methods

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Mechanical Engineering, Vallurupalli Nageswara Rao Vignana Jyothi Inst. of Engineering and Technology 1 , Vignana Jyothi Nagar, Bachupally, Nizam Pet (S.O.), Hyderabad500 090, IN

Department of Mechanical Engineering, Vallurupalli Nageswara Rao Vignana Jyothi Inst. of Engineering and Technology 2 , Vignana Jyothi Nagar, Bachupally, Nizam Pet (S.O.), Hyderabad500 090, IN

Department of Applied Mechanics, Motilal Nehru National Inst. of Engineering and Technology 3 , Allahabad211004, IN

Department of Health and Kinesiology, Univ. of Texas at Tyler 4 , 3900 University Blvd., Tyler, TX75799US

References (6)

Show source-provided references
1. Sandwich Test Specimens for Measuring Interface Crack Toughness10.1016/0921-5093(89)90382-1 ↗
2. Crack Path Selection in a Brittle Adhesive Layer10.1016/0020-7683(91)90069-R ↗
3. The Use of a Compact Sandwich Specimen to Evaluate Fracture Toughness and Interfacial Bonding
4. Recent Development in Specimens for Fracture Toughness Testing of Bone
5. 2012
6. Manual of Codes of Practice (Sept, 2000), for the Determination of Uncertainties in Mechanical Tests on Metallic Materials, Code of Practice Number 3, Project UNCERT