Comprehensive Analysis of Performance Data for Energized Vessel Sealing Devices
Source abstract
Abstract
Abstract Burst pressure and thermal spread are two key performance characteristics associated with the development of safe and effective energy-based vessel sealing and tissue transection devices. A thorough literature review revealed that a large percentage of studies describing assessments of burst pressure or thermal spread, or both, used univariate, single-factor inferential statistics as the primary source of analysis, with the Student’s t-test and one-way ANOVA being the most prevalent methods. In addition, there were only two examples of studies that discussed the approach for handling two correlated halves of a vessel seal created by vessel sealing and dividing devices. Use of analysis methods such as those described can result in a problematic mixing of known and unknown variability, as vessel diameter, specific device used, test gauge, particular tissue properties, and several other factors potentially have an impact on burst and thermal spread measurements. The consequences of this are potential confounding, a lack of sensitivity when comparing groups, and a general inability to better understand the factors and interactions involved with optimizing overall seal performance. This paper describes a study evaluating the performance of four energy-based vessel sealing devices, and it outlines the comprehensive method used for analyzing burst pressure and thermal spread measurements obtained from these devices. This approach incorporates covariates into the analysis, increasing overall study power and facilitating an enhanced understanding of experimental noise factors. Higher sensitivity in the analysis and identification of key experimental factors contributing to variability allows the utilization of an evidence-based approach to continuously improve test and analysis methods, and complete successive design iterations for the development of consistently safe and effective vessel sealing and tissue transection devices. Results from this comprehensive analysis method have been included in multiple domestic and international regulatory submissions.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Hydrogen embrittlement and corrosion behaviors in metals · Ultrasound and Hyperthermia Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Tissue Effect Research Group, Surgical Innovations, Advanced Energy & Stapling, Medtronic 1 , Boulder, CO, 80301, US
Tissue Effect Research Group, Surgical Innovations, Advanced Energy & Stapling, Medtronic 2 , Boulder, CO, 80301US
References (48)
Show source-provided references
1. Fundamentals of Electrosurgery Part I: Principles of Radiofrequency Energy for Surgery10.1007/978-1-4614-2074-3_2 ↗
2. A Review of Currently Available Vessel Sealing Systems10.1080/13645700601181414 ↗
3. Electrothermal Bipolar Vessel Sealing System (LigaSure) for Hemostasis During Thyroid Surgery: A Comprehensive Review10.1586/erd.13.6 ↗
4. Ultrasonic Energy Systems
5. Comparison of Two Histological Test Methods for the Measurement of Thermal Spread Associated With Energized Vessel Sealing10.1520/JTE20140233 ↗
6. To Knot or Not to Knot? Sutureless Haemostasis Compared to the Surgeon’s Knot10.1308/003588407X183418 ↗
7. Temperature Measurement Methods During Direct Heat Arterial Tissue Fusion10.1109/TBME.2013.2260542 ↗
8. Mechanical Test Methods for Assessing Porcine Carotid and Uterine Artery Burst Pressure Following Ex Vivo Ultrasonic Ligature Seal and Transection10.1520/JTE103120 ↗
9. Evaluation of a Vessel Sealing System, Bipolar Electrosurgery, Harmonic Scalpel, Titanium Clips, Endoscopic Gastrointestinal Anastomosis Vascular Staples and Sutures for Arterial and Venous Ligation in a Porcine Model10.1016/S0022-5347(05)63995-X ↗
10. Comparison of a Reusable With A Disposable Vessel-Sealing Device in a Sheep Model: Efficacy and Costs10.1016/j.fertnstert.2010.09.014 ↗
11. Sealing of Pulmonary Arteries With LigaSure: In Vivo and Ex Vivo Examinations10.1016/j.jtcvs.2012.11.009 ↗
12. Differential Response of Arteries and Veins to Bipolar Vessel Sealing: Evaluation of a Novel Reusable Device10.1089/lap.2006.16.149 ↗
13. The Nightknife: Evaluation of Efficiency and Quality of Bipolar Vessel Sealing10.1089/lap.2011.0191 ↗
14. Sealing Vessels up to 7 mm in Diameter Solely With Ultrasonic Technology
15. Efficacy and Safety of the Novel Electrosurgical Vessel Sealing and Cutting Instrument Bicision(R)10.1007/s00464-012-2337-x ↗
16. Evaluation of the Novel Bipolar Vessel Sealing and Cutting Device BiCision(R) in a Porcine Model10.3109/13645706.2012.661373 ↗
17. Efficiency and Safety of Bipolar Vessel and Tissue Sealing in Visceral Surgery10.3109/13645706.2011.651145 ↗
18. PlasmaKinetic Bipolar Vessel Sealing: Burst Pressures and Thermal Spread in an Animal Model10.1089/end.2005.19.107 ↗
19. Evaluation of Thermal Damage in a Pig Model10.3109/08941939.2011.591895 ↗
20. Comparison of Economic Bipolar Vessel Sealer and Biclamp for the Hemostasis of Large-Sized Cadaver Arteries
21. Tissue Effects in Vessel Sealing and Transection From an Ultrasonic Device With More Intelligent Control of Energy Delivery
22. Comparison of Linear and Torsional Mode Ultrasonic Coagulating Shears for the Sealing of Medium- to Large-Sized Arteries10.1007/s00464-006-9113-8 ↗
23. Thermal Spread and Heat Absorbance Differences Between Open and Laparoscopic Surgeries During Energized Dissections by Electrosurgical Instruments10.1007/s00464-009-0421-7 ↗
24. Application of Ice Cold Irrigation During Vascular Pedicle Control of Robot-Assisted Radical Prostatectomy: EnSeal Instrument Cooling to Reduce Collateral Thermal Tissue Damage10.1089/end.2010.0392 ↗
25. Evaluation of an Innovative, Cordless Ultrasonic Dissector10.1177/1553350612471206 ↗
26. Bipolar Electrosurgical Vessel-Sealing Device With Compressive Force Monitoring10.1115/1.4027269 ↗
27. Consistency and Sealing of Advanced Bipolar Tissue Sealers
28. Prospective Comparison of Four Laparoscopic Vessel Ligation Devices10.1089/end.2008.9715 ↗
29. Tissue Storage Ex Vivo Significantly Increases Vascular Fusion Bursting Pressure10.1007/s00464-014-3900-4 ↗
30. Experimental Comparison of Mesenteric Vessel Sealing and Thermal Damage Between One Bipolar and Two Ultrasonic Shears Devices10.1002/bjs.7433 ↗
31. Sealing of Vessels Larger Than 7 Millimeters Using Enseal in Porcine Aorta10.4293/JSLS.2014.00182 ↗
32. Evaluation of Surgical Energy Devices for Vessel Sealing and Peripheral Energy Spread in a Porcine Model10.1016/j.juro.2007.07.121 ↗
33. The Effect of Intraluminal Content on the Bursting Strength of Vessels Ligated With the Harmonic ACE and LigaSure V10.1089/end.2008.0079 ↗
34. Safety and Efficacy of New Integrated Bipolar and Ultrasonic Scissors Compared to Conventional Laparoscopic 5-mm Sealing and Cutting Instruments10.1007/s00464-012-2229-0 ↗
35. Tissue Response to Surgical Energy Devices10.1016/j.urology.2007.11.035 ↗
36. Comparison of Ultrasonic Energy, Bipolar Thermal Energy, and Vascular Clips for the Hemostasis of Small-, Medium-, and Large-Sized Arteries10.1007/s00464-002-8833-7 ↗
37. Evaluation of the Safety, Efficacy, and Versatility of a New Surgical Energy Device (THUNDERBEAT) in Comparison With Harmonic ACE, LigaSure V, and EnSeal Devices in a Porcine Model10.1089/lap.2011.0420 ↗
38. Comparison of Blood Vessel Sealing Among New Electrosurgical and Ultrasonic Devices10.1007/s00464-008-9932-x ↗
39. Comparison of Four Energy-Based Vascular Sealing and Cutting Instruments: A Porcine Model10.1007/s00464-007-9619-8 ↗
40. A Prospective Study of In Vivo and Ex Vivo Sealing of the Human Inferior Mesenteric Artery Using an Electrothermal Bipolar Vessel-Sealing Device10.1089/lap.2013.0524 ↗
41. Evaluation of EnSeal(R), an Adaptive Bipolar Electrosurgical Tissue-Sealing Device10.1556/avet.2012.003 ↗
42. Comparison of Two Different Energy-Based Vascular Sealing Systems for the Hemostasis of Various Types of Arteries: A Porcine Model-Evaluation of LigaSure ForceTriad10.1089/lap.2009.0438 ↗
43. Collagen-Elastin Ratio Predicts Burst Pressure of Arterial Seals Created Using a Bipolar Vessel Sealing Device in a Porcine Model10.1007/s00464-011-1606-4 ↗
44. A Comparison of Laparoscopic Bipolar Vessel Sealing Devices in the Hemostasis of Small-, Medium-, and Large-Sized Arteries10.1089/109264203322656441 ↗
45. Design of a Factorial Experiment With Randomization Restrictions to Assess Medical Device Performance on Vascular Tissue10.1186/1471-2288-11-75 ↗
46. Thermal Fusion: Effects and Interactions of Temperature, Compression, and Duration Variables10.1007/s00464-012-2386-1 ↗
47. Sahai · 200010.1007/978-1-4612-1344-4 ↗
48. What is an Intracluster Correlation Coefficient? Crucial Concepts for Primary Care Researchers10.1370/afm.141 ↗