journal article·2014-11Open access

Monitoring Early Hydration of Cement by Ex Situ and In Situ ATR‐FTIR – a Comparative Study

Rikard Ylmén, Ulf Jäglid, Itai Panas

Abstract

Diffuse Reflection Fourier Transform Infrared ( DR ‐ FTIR ) spectroscopy has previously proven to provide time‐resolved insights into early cement hydration spanning ~30 s to ~36 h after completing the mixing. Here, a previously validated ex situ freeze‐dry procedure to stop hydration at preset times is complemented by an in situ Attenuated Total Reflectance ( ATR ) infrared spectroscopy method. The qualitative overall agreement between ex situ freeze‐drying and in situ monitoring is demonstrated. Moreover, water conversion during hydration comes out clearly in the time‐resolved ATR ‐ FTIR spectra. This information is absent in DR ‐ FTIR where buildups of crystal water and hydroxides are observed, while quenching of the hydration process requires removal of free water prior to acquiring the spectra. The ability of the IR technique to monitor the initial rate of hydration as a function of time is validated by comparing to calorimetry. The two approaches are understood to be complementary in that the former monitors alite grain surface hydration, while the latter reflects bulk hydration. IR is complementary to the calorimetry in cases of surface processes in conjunction with low enthalpy changes, that is, initial C–S–H formation and additive related surface chemistry.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Concrete and Cement Materials Research · Building materials and conservation · Concrete Properties and Behavior

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Chemical and Biological Engineering Chalmers University of Technology Göteborg SE‐412 96 Sweden

References (16)

Show source-provided references
1. 10.1016/j.msea.2011.10.10210.1016/j.msea.2011.10.102 ↗
2. 10.1007/s10853-006-0467-z10.1007/s10853-006-0467-z ↗
3. 10.1016/j.cemconres.2012.10.00710.1016/j.cemconres.2012.10.007 ↗
4. 10.1016/j.enbuild.2012.12.01410.1016/j.enbuild.2012.12.014 ↗
5. 10.1016/j.cplett.2004.05.07110.1016/j.cplett.2004.05.071 ↗
6. 10.1016/j.cemconres.2011.10.00810.1016/j.cemconres.2011.10.008 ↗
7. 10.1111/j.1151-2916.1999.tb01826.x10.1111/j.1151-2916.1999.tb01826.x ↗
8. 10.1016/j.cemconres.2009.01.01710.1016/j.cemconres.2009.01.017 ↗
9. 10.1016/j.cemconres.2010.06.00810.1016/j.cemconres.2010.06.008 ↗
10. R.Ylmén U.Jäglid B.‐M.Steenari andI.Panas “A Method for the Study of Early Hydration of Portland Cement with DR‐FTIR”; pp.399–405in Proceedings of The Third North American Conference on the Design and Use of Self‐Consolidating Concrete SCC Chicago IL November 10–12 2008.
11. Applications of an Eight‐Channel Isothermal Conduction Calorimeter for Cement Hydration Studies
12. 10.1007/s10973-008-9409-010.1007/s10973-008-9409-0 ↗
13. Determining Cement Composition by Fourier Transform Infrared Spectroscopy10.1016/1065-7355(94)00031-X ↗
14. 10.1016/S0008-8846(99)00243-410.1016/S0008-8846(99)00243-4 ↗
15. 10.1016/0008-8846(80)90005-810.1016/0008-8846(80)90005-8 ↗
16. 10.1016/S0924-2031(01)00139-410.1016/S0924-2031(01)00139-4 ↗