journal article·2019-03Open access

In situ measurements of reactions in a glass‐forming batch by X‐ray and neutron diffraction

Irene M. Peterson, Ying Shi, Dong Ma, Jennifer L. Rygel, Bryan Wheaton, Pamela S. Whitfield, Joseph Wright, Michele Carlineo

Abstract

Abstract The batch materials used in glass production are often too coarse to allow phase evolution measurements by in situ high‐temperature x‐ray diffraction (HTXRD). Reducing the particle sizes to accommodate these measurements changes the reaction kinetics and can alter the reaction pathway. Unlike conventional laboratory XRD, which operates in reflection mode and analyzes the surface region of finely ground powder, neutron diffraction can be used to characterize as‐received batch materials by means of an intense beam which penetrates through a bulk sample. In this study, the phase evolution in a glass‐forming batch made with fine batch materials was probed in situ by both HTXRD and time‐of‐flight neutron diffraction to determine the similarities and differences between measurements by the two techniques. Then, the same composition, prepared using the coarser, as‐received size distributions of the same batch materials, was studied by both techniques, demonstrating the unique capability of neutron diffraction to analyze material which is too coarse for the HTXRD, and to reveal the effect of the particle size distribution on the reaction kinetics.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Glass properties and applications · Nuclear materials and radiation effects · X-ray Diffraction in Crystallography

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Corning Research and Development Corporation Corning New York

Neutron Scattering Division Spallation Neutron Source Oak Ridge National Laboratory Oak Ridge Tennessee

Excelsus Structural Solutions Park Innovaare Villigen Switzerland

Funding

U.S. Department of Energy

References (25)

Show source-provided references
1. 10.1016/j.jnucmat.2013.07.03910.1016/j.jnucmat.2013.07.039 ↗
2. Tooley F · 1974 · 513
3. Verheijen O · 2003
4. 10.1016/j.tca.2012.04.01910.1016/j.tca.2012.04.019 ↗
5. Pierce D · 2013 · 429
6. 10.1111/j.2041-1294.2012.00079.x10.1111/j.2041-1294.2012.00079.x ↗
7. Analysis of glass batch reactions using in‐situ x‐ray diffraction. Part 2: soda‐lime silica batches
8. 10.1023/A:100470692253010.1023/A:1004706922530 ↗
9. 10.1016/j.jnoncrysol.2010.11.09610.1016/j.jnoncrysol.2010.11.096 ↗
10. 10.1002/9781119282471.ch410.1002/9781119282471.ch4 ↗
11. 10.1002/9781118932964.ch710.1002/9781118932964.ch7 ↗
12. Cullity BD · 2001
13. 10.1201/978020340281810.1201/9780203402818 ↗
14. 10.1093/acprof:oso/9780198515944.001.000110.1093/acprof:oso/9780198515944.001.0001 ↗
15. 10.1111/jace.1229810.1111/jace.12298 ↗
16. 10.1007/s11661-010-0495-910.1007/s11661-010-0495-9 ↗
17. 10.1007/s11661-011-0667-210.1007/s11661-011-0667-2 ↗
18. 10.1016/j.actamat.2013.11.01210.1016/j.actamat.2013.11.012 ↗
19. 10.1038/ncomms617810.1038/ncomms6178 ↗
20. 10.1107/S002188988201272210.1107/S0021889882012722 ↗
21. AnK.VDRIVE‐data reduction and interative visualization software for event mode neutron diffraction. In: Oak Ridge National Laboratory Report ORNL‐TM‐2012‐621. Oak Ridge National Laboratory;2012.
22. 10.1107/S205252061600233X10.1107/S205252061600233X ↗
23. 10.1103/PhysRevB.51.675810.1103/PhysRevB.51.6758 ↗
24. 10.1180/00264610175037752410.1180/002646101750377524 ↗
25. 10.1111/j.1551-2916.2012.05151.x10.1111/j.1551-2916.2012.05151.x ↗