Stability of Birefringence in Glass Articles
Source abstract
Abstract
If strain is induced in disks of window glass by relatively rapid cooling in the annealing range (about 500 °C.), the birefringence seems to be permanent in its entirety at room temperatures (about 30 °C.). Even the most delicate polariscopes fail to detect any change in 11 years. At temperatures far below the annealing range, however, it is possible to remove some of this strain. Sometimes 5 to 10% can be removed at temperatures of 180° and 200 °C. in a period of 30 days. At 200 °C. a second 30‐day heating period produced no further change; at 250 °C., it produced another slight decrease.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Cultural Heritage Materials Analysis · Structural Analysis of Composite Materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (7)
Show source-provided references
1. Preparation of Standard Glass Disks for the Testing of Internal Strain in Glassware
2. 10.1111/j.1151-2916.1945.tb14494.x10.1111/j.1151-2916.1945.tb14494.x ↗
3. 10.1016/S0016-0032(33)90918-710.1016/S0016-0032(33)90918-7 ↗
4. Annealing of Glass
5. 10.1111/j.1151-2916.1930.tb16317.x10.1111/j.1151-2916.1930.tb16317.x ↗
6. 10.1111/j.1151-2916.1943.tb15215.x10.1111/j.1151-2916.1943.tb15215.x ↗
7. 10.1111/j.1151-2916.1936.tb19794.x10.1111/j.1151-2916.1936.tb19794.x ↗