Some Experiments in Comparing the Resistance of Enamels to Corrosion by Alkaline Solutions
Source abstract
Abstract
Experiments are described which show the effects of solution temperature, concentration, container material, and specimen position on the rate of dissolution of sheet‐steel and cast‐iron enamels by alkaline solutions. The results indicate that in designing apparatus to measure such corrosion rates the solution temperature should be controlled to at least ±0.1°C., that no glass parts of the apparatus should be exposed to the solution, and that, in the absence of stirring, consideration should be given to the positioning of the specimens. Corrosion test apparatus is described which was designed to meet these requirements.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Structural Analysis of Composite Materials · Metallurgical Processes and Thermodynamics · Recycling and utilization of industrial and municipal waste in materials production
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (11)
Show source-provided references
1. 1940 · 11
2. 10.1111/j.1151-2916.1949.tb18956.x10.1111/j.1151-2916.1949.tb18956.x ↗
3. Grundsätzliches über die chemische Angreifbarkeit von Gläsern, I” (Fundamental Considerations on the Chemical Stability of Glasses, I)
4. 10.6028/jres.027.00510.6028/jres.027.005 ↗
5. 10.6028/jres.039.02410.6028/jres.039.024 ↗
6. 10.1021/j150498a00210.1021/j150498a002 ↗
7. Polymerization of Silicic Acid; Catalytic Effect of Fluoride
8. Correlation of Laboratory and Service Data on Porcelain Enamels
9. 1942 · 11
10. 10.6028/jres.048.05510.6028/jres.048.055 ↗
11. Morey G. W. · 1954 · 105