Microhardness and corrosion resistance of plasma sprayed bioceramic bilayer coated Ti-6Al-4V implants
Source abstract
Abstract
The present work explores the mechanical and corrosion resistance properties of Al2O3-13wt% TiO2 (AT13) and hydroxyapatite (HAP) bilayer coated titanium alloy (Ti-6Al-4V) bioimplants. Plasma spray coated AT13 acts as the foundation layer (thickness 75 μm) and HAP acts as the top layer (thickness 75 μm). AT13/HAP bilayer coated Ti-6Al-4V implants were characterized in terms of microstructure, chemical composition, hardness and surface roughness. The corrosion resistance and bioactivity were investigated in simulated body fluid (SBF) environment at 37 °C. The results validated that bilayer coated Ti-6Al-4V implants possessed superior corrosion resistance, polarization resistance and microhardness in comparison with monolayer coated and uncoated implants.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty · Titanium Alloys Microstructure and Properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (27)
Show source-provided references
1. Sathish, S., Geetha, M., Aruna, S.T., Balaji, N., Rajam, K.S., Asokamani, R.: Studies on plasma sprayed bi-layered ceramic coating on bio-medical Ti–13Nb–13Zr alloy. Ceram Int. 37, 1333–1339 (2011)10.1016/j.ceramint.2010.12.012 ↗
2. Sato, M., Sambito, M.A., Aslani, A., Kalkhoran, N.M., Slamovich, E.B., Webster, T.J.: Increased osteoblast functions on undoped and yttrium-doped nanocrystalline hydroxyapatite coatings on titanium. Biomaterials. 27, 2358–2369 (2006)10.1016/j.biomaterials.2005.10.041 ↗
3. Vahey, J.W., Simonia, P.T., Conrad, E.U.: Carcinogenicity and metallic implants. Am J Orthod Dentofac Orthop. 24, 319–324 (1995)
4. Arvideon, K., Cottler-Fox, M., Friberg, U.: Cytotoxic effects of Co-Cr alloys on fibroblast derived form human gingiva. Scand J Dent Res. 95, 356–363 (1986)
5. Lin Sun, Z., Wtaha, J.C., Hanks, C.T.: Effect of metals ions on osteoblast-like cell metabolism and differentiation. J Biomed Mater Res. 34, 29–37 (1997)10.1002/(SICI)1097-4636(199701)34:1<29::AID-JBM5>3.0.CO;2-P ↗
6. Normand, B., Fervel, V., Coddet, C., Nikitine, V.: Tribological properties of plasma sprayed alumina–titania coatings: role and control of the microstructure. Surf Coat Technol. 123, 278–287 (2000)10.1016/S0257-8972(99)00532-0 ↗
7. Balamurugan, A., Balossier, G., Kannan, S., Michel, J., Faure, J., Rajeswari, S.: Electrochemical and structural characterisation of zirconia reinforced hydroxyapatite bioceramic sol–gel coatings on surgical grade 316L SS for biomedical applications. Ceram Int. 33, 605–614 (2007)10.1016/j.ceramint.2005.11.011 ↗
8. Solla, E.L., Gonzalez, P., Serra, J., Chiussi, S., Leon, B., Garcıa Lopez, J.: Pulsed laser deposition of silicon substituted hydroxyapatite coatings from synthetical and biological sources. Appl Surf Sci. 254, 1189–1193 (2007)10.1016/j.apsusc.2007.09.041 ↗
9. Lu, Y.-P., Song, Y.-Z., Zhu, R.-F., Li, M.-S., Lei, T.-Q.: Factors influencing phase compositions and structure of plasma sprayed hydroxyapatite coating during heat treatment. Appl Surf Sci. 206, 345–354 (2003)10.1016/S0169-4332(02)01308-9 ↗
10. Li, H., Khor, K.A., Cheang, P.: Impact formation and microstructure characterization of thermal sprayed hydroxyapatite/ titania composite coatings. Biomaterials. 24, 949–957 (2003)10.1016/S0142-9612(02)00431-3 ↗
11. Ahmed, H.S.T., Jankowski, A.F.: Strain rate sensitivity of hydroxyapatite coatings. Thin Solid Films. 520, 1516–1519 (2011)10.1016/j.tsf.2011.06.004 ↗
12. Kaciulis, S., Mattogno, G., Pandolfi, L., Cavalli, M., Gnappi, G., Montenero, A.: XPS study of apatite-based coatings prepared by sol–gel Technique. Appl Surf Sci. 151, 1–5 (1999)10.1016/S0169-4332(99)00267-6 ↗
13. Fathi, M.H., Salehi, M., Saatchi, A., Mortazavi, V., Moosavi, S.B.: in vitro corrosion behavior of bioceramic, metallic, and bioceramic-metallic coated stainless steel dental implants. Dent.Mater. 19, 188–198 (2003)10.1016/S0109-5641(02)00029-5 ↗
14. Wang, Y., Zhang, S., Zeng, X., Cheng, K., Qian, M., Weng, W.: In vitro behavior of fluoridated hydroxyapatite coatings in organic-containing simulated body fluid. Mater Sci Eng C. 27, 244–250 (2007)10.1016/j.msec.2006.03.012 ↗
15. Kodama, A., Bauer, S., Komatsu, A., Asoh, H., OnO, S., Schmuki, P.: Bioactivation of titanium surfaces using coatings of TiO2 nanotubes rapidly pre-loaded with synthetic hydroxyapatite. Acta Biomater. 5, 2322–2330 (2009)10.1016/j.actbio.2009.02.032 ↗
16. Bigi, A., Boanini, E., Bracci, B., Facchini, A., Panzavolta, S., Segatti, F., Sturb, L.: Nanocrystalline hydroxyapatite coatings on titanium new fast Biomimetic method. Biomaterials. 26, 4085–4089 (2005)10.1016/j.biomaterials.2004.10.034 ↗
17. Luo, Z.S., Cui, F.Z., Feng, Q.L., Li, H.D., Zhu, X.D., Spector, M.: In vitro and in vivo evaluation of degradability of hydroxyapatite coatings synthesized by ion beam-assisted deposition. Surf Coat Technol. 131, 192–195 (2000)10.1016/S0257-8972(00)00824-0 ↗
18. Bigi, A., Fini, M., Bracci, B., Boanini, E., Torricelli, P., Giavaresi, G., Aldini, N.N., Facchini, A., Sbaiz, F., Giardino, R.: The response of bone to nanocrystalline hydroxyapatite-coated Ti1 3Nb 11Zr alloy in an animal model. Biomaterials. 29, 1730–1736 (2008)10.1016/j.biomaterials.2007.12.011 ↗
19. Song, Y., Zhang, S., Li, J., Zhao, C., Zhang, X.: Electrodeposition of Ca-P coatings on biodegradable Mg alloy: in vitro biomineralization behavior. Acta Biomater. 6, 1736–1742 (2010)10.1016/j.actbio.2009.12.020 ↗
20. Bakan, F., Laçin, O., Sarac, H.: A novel low temperature sol–gel synthesis process for thermally stable nano crystalline hydroxyapatite. Powder Technol. 233, 295–302 (2013)10.1016/j.powtec.2012.08.030 ↗
21. Richard, C., Kowandy, C., Landoulsi, J., Geetha, M., Ramasawmy, H.: Corrosion and wear behavior of thermally sprayed nano ceramic coatings on commercially pure Titanium and Ti–13Nb–13Zr substrates. Int J Refract Met Hard Mater. 28, 115–123 (2010)10.1016/j.ijrmhm.2009.08.006 ↗
22. Kokubo, T.: Surface chemistry of bioactive glass ceramics. J Non-Cryst Solids. 120, 138–151 (1990)10.1016/0022-3093(90)90199-V ↗
23. Saber-Samandari, S., Alamara, K., Saber-Samandari, S., Gross, K.A.: Micro-Raman spectroscopy shows how the coating process affects the characteristics of hydroxylapatite. Acta Biomater. 9, 9538–9546 (2013)10.1016/j.actbio.2013.08.021 ↗
24. J.C. Elliott, E. Bres, P. Hardouin, Calcium phosphate materials, fundamentals, Sauramps Medical, Montpellier, 1998, 25-66.
25. Jones, D.A.: Principles and prevention of corrosion. Macmillan, New York (1992)
26. Creus, J., Mazille, H., Idrissi, H.: Porosity evaluation of protective coatings onto steel,through electrochemical techniques. Surf.Coat.Technol. 130, 224–232 (2000)10.1016/S0257-8972(99)00659-3 ↗
27. Madhan Kumar, A., Rajendran, N.: Influence of zirconia nanoparticles on the surface and electrochemical behaviour of polypyrrole nanocomposites coated 316LSS in simulated body fluid. Surf.Coat.Technol. 213, 155–166 (2012)10.1016/j.surfcoat.2012.10.039 ↗