Development of ceramic layer on magnesium and its alloys for bone implant applications using plasma electrolytic oxidation (PEO)
Bibliographic record
Abstract
No abstract is available for this record. The assistant can identify its topic from the title, but cannot infer the study’s results.
Source: Not provided · Quality: missing
Research context
OpenAlex topics: Magnesium Alloys: Properties and Applications · Aluminum Alloys Composites Properties · Bone Tissue Engineering Materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (100+)
Show source-provided references
1. Akhtar, M., Uzair, S.A., Rizwan, M., Ur Rehman, M.A.: The improvement in surface properties of metallic implant via magnetron sputtering: recent progress and remaining challenges. Front. Mater. 8 (2022)10.3389/fmats.2021.747169 ↗
2. Akram, M., Arshad, N., Braem, A.: Fabrication of corrosion-resistant chitosan–gelatin–bioactive glass-ZnO/CeO 2 hybrid coating on magnesium ZK60 alloy by AC-EPD. J. Taibah Univ. Sci. 15(1), 312–320 (2021). https://doi.org/10.1080/16583655.2021.197881210.1080/16583655.2021.1978812 ↗
3. Akram, M., Arshad, N., Braem, A.: Fabrication of corrosion-resistant chitosan–gelatin–bioactive glass-ZnO/CeO2 hybrid coating on magnesium ZK60 alloy by AC-EPD. J. Taibah Univ. Sci. 15(1), 312–320 (2021). https://doi.org/10.1080/16583655.2021.197881210.1080/16583655.2021.1978812 ↗
4. Bagheri, R.: Bioactive glasses in dentistry: a review, vol. 2. (2015)
5. Bansal, P., Singh, G., Sidhu, H.S.: Investigation of surface properties and corrosion behavior of plasma sprayed HA/ZnO coatings prepared on AZ31 Mg alloy. Surf. Coat. Technol. 401 (2020). https://doi.org/10.1016/j.surfcoat.2020.12624110.1016/j.surfcoat.2020.126241 ↗
6. Barati Darband, Gh., Aliofkhazraei, M., Hamghalam, P., Valizade, N.: Plasma electrolytic oxidation of magnesium and its alloys: Mechanism, properties and applications. J. Magnesium Alloys 5(1), 74–132 (2017)10.1016/j.jma.2017.02.004 ↗
7. Barber, C.C., Burnham, M., Ojameruaye, O., McKee, M.D.: A systematic review of the use of titanium versus stainless steel implants for fracture fixation. OTA Int. 4(3), e138 (2021)10.1097/OI9.0000000000000138 ↗
8. Bekmurzayeva, A., Duncanson, W.J., Azevedo, H.S., Kanayeva, D.: Surface modification of stainless steel for biomedical applications: revisiting a century-old material. Mater. Sci. Eng. C 93, 1073–1089 (2018)10.1016/j.msec.2018.08.049 ↗
9. Benrezgua, E., Deghfel, B., Zoukel, A., Basirun, W.J., Amari, R., Boukhari, A., Yaakob, M.K., Kheawhom, S., Mohamad, A.A.: Synthesis and properties of copper doped zinc oxide thin films by Sol-Gel, spin coating and dipping: a characterization review. J. Mol. Struct. 1267 (2022)10.1016/j.molstruc.2022.133639 ↗
10. Bommala, V.K., Krishna, M.G., Rao, C.T.: Magnesium matrix composites for biomedical applications: A review. J. Magnesium Alloys 7(1), 72–79 (2019)10.1016/j.jma.2018.11.001 ↗
11. Bordbar-Khiabani, A., Yarmand, B., Mozafari, M.: Enhanced corrosion resistance and in-vitro biodegradation of plasma electrolytic oxidation coatings prepared on AZ91 Mg Alloy using ZnO nanoparticles-incorporated electrolyte. Surf. Coat. Technol. 360, 153–171 (2019). https://doi.org/10.1016/j.surfcoat.2019.01.00210.1016/j.surfcoat.2019.01.002 ↗
12. Castellani, C., Lindtner, R.A., Hausbrandt, P., Tschegg, E., Stanzl-Tschegg, S.E., Zanoni, G., Beck, S., Weinberg, A.-M.: Bone–implant interface strength and osseointegration: Biodegradable magnesium alloy versus standard titanium control. Acta Biomater. 7(1), 432–440 (2011)10.1016/j.actbio.2010.08.020 ↗
13. Chaharmahali, R., Fattah-Alhosseini, A., Esfahani, H.: Plasma electrolyte oxidation of hydroxyapatite-containing coating on AZ31B Mg alloy: Effects of current density and duty cycle. J. Ultrafine Grained Nanostruct. Mater. 54(2), 149–162 (2021). https://doi.org/10.22059/jufgnsm.2021.02.0410.22059/jufgnsm.2021.02.04 ↗
14. Chang, L.: Growth regularity of ceramic coating on magnesium alloy by plasma electrolytic oxidation. J. Alloy. Compd. 468(1–2), 462–465 (2009). https://doi.org/10.1016/j.jallcom.2008.01.06910.1016/j.jallcom.2008.01.069 ↗
15. Cheng, Y.L., Mao, M.K., Cao, J.H., Peng, Z.M.: Plasma electrolytic oxidation of an Al-Cu-Li alloy in alkaline aluminate electrolytes: A competition between growth and dissolution for the initial ultra-thin films. Electrochim. Acta 138, 417–429 (2014). https://doi.org/10.1016/j.electacta.2014.06.12210.1016/j.electacta.2014.06.122 ↗
16. Cruz, M.B., Silva, N., Marques, J.F., Mata, A., Silva, F.S., Caramês, J.: “Biomimetic implant surfaces and their role in biological integration—a concise review.” Biomimetics 7(2), (2022)10.3390/biomimetics7020074 ↗
17. Curran, J.A., Clyne, T.W.: Porosity in plasma electrolytic oxide coatings. Acta Mater. 54(7), 1985–1993 (2006). https://doi.org/10.1016/j.actamat.2005.12.02910.1016/j.actamat.2005.12.029 ↗
18. Dehnavi, V., Shoesmith, D.W., Luan, B.L., Yari, M., Liu, X.Y., Rohani, S.: Corrosion properties of plasma electrolytic oxidation coatings on an aluminium alloy - the effect of the PEO process stage. Mater. Chem. Phys. 161, 49–58 (2015). https://doi.org/10.1016/j.matchemphys.2015.04.05810.1016/j.matchemphys.2015.04.058 ↗
19. Dittler, M.L., Unalan, I., Grünewald, A., Beltrán, A.M., Grillo, C.A., Destch, R., Gonzalez, M.C., Boccaccini, A.R.: “Bioactive glass (45S5)-based 3D scaffolds coated with magnesium and zinc-loaded hydroxyapatite nanoparticles for tissue engineering applications.” Colloids Surf. B: Biointerfaces 182, (2019). https://doi.org/10.1016/j.colsurfb.2019.11034610.1016/j.colsurfb.2019.110346 ↗
20. Dong, J., Lin, T., Shao, H., Wang, H., Wang, X., Song, K., Li, Q.: “Advances in degradation behavior of biomedical magnesium alloys: A review.” J. Alloys Compd. 90810.1016/j.jallcom.2022.164600 ↗
21. Dou, Y., Cai, S., Ye, X., Xu, G., Huang, K., Wang, X., Ren, M.: 45S5 bioactive glass-ceramic coated AZ31 magnesium alloy with improved corrosion resistance. Surf. Coat. Technol. 228, 154–161 (2013). https://doi.org/10.1016/j.surfcoat.2013.04.02210.1016/j.surfcoat.2013.04.022 ↗
22. Duan, H., Yan, C., Wang, F.: Effect of electrolyte additives on performance of plasma electrolytic oxidation films formed on magnesium alloy AZ91D. Electrochim. Acta 52(11), 3785–3793 (2007). https://doi.org/10.1016/j.electacta.2006.10.06610.1016/j.electacta.2006.10.066 ↗
23. Durdu, S., Aytaç, A., Usta, M.: Characterization and corrosion behavior of ceramic coating on magnesium by micro-arc oxidation. J. Alloy. Compd. 509(34), 8601–8606 (2011). https://doi.org/10.1016/j.jallcom.2011.06.05910.1016/j.jallcom.2011.06.059 ↗
24. Dutta, S., Bavya Devi, K., Gupta, S., Kundu, B., Balla, V.K., Roy, M.: Mechanical and in vitro degradation behavior of magnesium-bioactive glass composites prepared by SPS for biomedical applications. J. Biomed. Mater. Res. - Part B Appl. Biomater. 107(2), 352–365 (2019). https://doi.org/10.1002/jbm.b.3412710.1002/jbm.b.34127 ↗
25. Echeverry-Rendon, M., Duque, V., Quintero, D., Harmsen, M.C., Echeverria, F.: Novel coatings obtained by plasma electrolytic oxidation to improve the corrosion resistance of magnesium-based biodegradable implants. Surf. Coat. Technol. 354, 28–37 (2018). https://doi.org/10.1016/j.surfcoat.2018.09.00710.1016/j.surfcoat.2018.09.007 ↗
26. Esmaili, S., Ahmadi, T., Nourbakhsh, A.A., Bakhsheshi-Rad, H.R., Berto, F.: Corrosion behavior and biocompatibility of graphene oxide-plasma electrolytic oxidation coating on magnesium alloy. Phys. Mesomech. 25(6), 583–599 (2022). https://doi.org/10.1134/S102995992206010810.1134/S1029959922060108 ↗
27. Farag, M.M., Ahmed, H.Y., Al-Rashidy, Z.M.: Improving the corrosion resistance of magnesium alloy by magnesium phosphate/glass composite coatings using sol-gel method. Silicon (2022). https://doi.org/10.1007/s12633-022-02226-010.1007/s12633-022-02226-0 ↗
28. Farraro, K.F., Kim, K.E., Woo, S.L.Y., Flowers, J.R., McCullough, M.B.: Revolutionizing orthopaedic biomaterials: The potential of biodegradable and bioresorbable magnesium-based materials for functional tissue engineering. J. Biomech. 47(9), 1979–1986 (2014)10.1016/j.jbiomech.2013.12.003 ↗
29. Farshid, S., Kharaziha, M.: Micro and nano-enabled approaches to improve the performance of plasma electrolytic oxidation coated magnesium alloys. J. Magnesium Alloys 9(5), 1487–1504 (2021)10.1016/j.jma.2020.11.004 ↗
30. Fattah-alhosseini, A., Chaharmahali, R., Babaei, K., Nouri, M., Keshvarz, M.K., Kaseem, M.: A review of effective strides in amelioration of the biocompatibility of PEO coatings on Mg alloys. J. Magnesium Alloys (2022). https://doi.org/10.1016/j.jma.2022.09.00210.1016/j.jma.2022.09.002 ↗
31. Fattah-alhosseini, A., Chaharmahali, R., Kaseem, M.: “Corrosion behavior amelioration of Ti-based alloys by the hybrid plasma electrolytic oxidation (PEO)/polymer coatings: A review.” Hybrid Adv. 100151, (2024)10.1016/j.hybadv.2024.100151 ↗
32. Ghasemi, A., Raja, V.S., Blawert, C., Dietzel, W., Kainer, K.U.: The role of anions in the formation and corrosion resistance of the plasma electrolytic oxidation coatings. Surf. Coat. Technol. 204(9–10), 1469–1478 (2010). https://doi.org/10.1016/j.surfcoat.2009.09.06910.1016/j.surfcoat.2009.09.069 ↗
33. Gray, J.E., Luan, B.: Protective coatings on magnesium and its alloys-a critical review. 336, (2002)10.1016/S0925-8388(01)01899-0 ↗
34. Gunawarman, Affi, J., Sutanto, A., Putri, D.M., Juliadmi, D., Nuswantoro, N.F., Fajri, H., Tjong, D.H., Manjas, M.: Adhesion strength of hydroxyapatite coating on titanium alloy (Ti-6Al-4V ELI) for biomedical application. In: IOP Conference Series: Materials Science and Engineering, vol. 1062. IOP Publishing Ltd (2021)10.1088/1757-899X/1062/1/012031 ↗
35. Guo, H.F., An, M.Z.: Growth of ceramic coatings on AZ91D magnesium alloys by micro-arc oxidation in aluminate-fluoride solutions and evaluation of corrosion resistance. Appl. Surf. Sci. 246(1–3), 229–238 (2005). https://doi.org/10.1016/j.apsusc.2004.11.03110.1016/j.apsusc.2004.11.031 ↗
36. Hadzhieva, Z., Boccaccini. A.R.: “Recent developments in electrophoretic deposition (EPD) of antibacterial coatings for biomedical applications - a review.” Curr. Opinion Biomed. Eng. 21, (2022)10.1016/j.cobme.2021.100367 ↗
37. Haider, A.J., Alawsi, T., Mohamme, J., Taha, B.A., Marhoon, H.A.: A comprehensive review on pulsed laser deposition technique to effective nanostructure production: trends and challenges. Opt. Quant. Electron. 54(8) (2022)10.1007/s11082-022-03786-6 ↗
38. Han, B., Yang, Y., Deng, H., Chen, Y., Yang, C.: Plasma-electrolytic-oxidation coating containing Y2O3 nanoparticles on AZ91 magnesium alloy. Int. J. Electrochem. Sci. 13(6), 5681–5697 (2018)10.20964/2018.06.66 ↗
39. Heimann, R.B.: Magnesium alloys for biomedical application: Advanced corrosion control through surface coating. Surf. Coat. Technol. 405, 126521 (2021)10.1016/j.surfcoat.2020.126521 ↗
40. Heimann, R.B.: “Magnesium alloys for biomedical application: advanced corrosion control through surface coating.” Surf. Coat. Technol. 405, (2021a). https://doi.org/10.1016/j.surfcoat.2020.12652110.1016/j.surfcoat.2020.126521 ↗
41. Heimann, R.B.: “Magnesium alloys for biomedical application: Advanced corrosion control through surface coating.” Surf. Coat. Technol. 405, (2021b). https://doi.org/10.1016/j.surfcoat.2020.12652110.1016/j.surfcoat.2020.126521 ↗
42. Heydarian, A., Atapour, M., Hakimizad, A., Raeissi, K.: “The effects of anodic amplitude and waveform of applied voltage on characterization and corrosion performance of the coatings grown by plasma electrolytic oxidation on AZ91 Mg Alloy from an Aluminate Bath.” Surf. Coat. Technol. 383, (2020). https://doi.org/10.1016/j.surfcoat.2019.12523510.1016/j.surfcoat.2019.125235 ↗
43. Hosseini, M., Khalil-Allafi, J., Etminanfar, M., Safavi, M.S., Bloise, N., Ghalandarzadeh, A.: “Tackling the challenges facing the clinical applications of pure PEO hydroxyapatite layers: Co-Deposition of YSZ Nanoparticles.” Mater. Chem. Phys. 293, (2023). https://doi.org/10.1016/j.matchemphys.2022.12689910.1016/j.matchemphys.2022.126899 ↗
44. Huang, K., Cai, S., Guohua, Xu., Ren, M., Wang, X., Zhang, R., Niu, S., Zhao, H.: Sol-gel derived mesoporous 58S bioactive glass coatings on AZ31 magnesium alloy and in vitro degradation behavior. Surf. Coat. Technol. 240, 137–144 (2014). https://doi.org/10.1016/j.surfcoat.2013.12.02610.1016/j.surfcoat.2013.12.026 ↗
45. Hussein, R.O.: Scholarship at UWindsor Scholarship at UWindsor Electronic Theses and Dissertations Theses, Dissertations, and Major Papers Plasma Process Control for Improved PEO Coatings on Plasma Process Control for Improved PEO Coatings on Magnesium Alloys Magnesium Alloys. (2015)
46. Hussein, R.O., Northwood, D.O., Nie, X.: The effect of processing parameters and substrate composition on the corrosion resistance of plasma electrolytic oxidation (PEO) coated magnesium alloys. Surf. Coat. Technol. 237, 357–368 (2013). https://doi.org/10.1016/j.surfcoat.2013.09.02110.1016/j.surfcoat.2013.09.021 ↗
47. Jabbarzare, S., Bakhsheshi-Rad, H.R., Nourbakhsh, A.A., Ahmadi, T., Berto, F.: Effect of graphene oxide on the corrosion, mechanical and biological properties of Mg-based nanocomposite. Int. J. Miner. Metall. Mater. 29(2), 305–319 (2022). https://doi.org/10.1007/s12613-020-2201-210.1007/s12613-020-2201-2 ↗
48. Jafarzadeh, A., Ahmadi, T., Dehaghani, M.T., Mohemi, K.: Synthesis, corrosion and bioactivity evaluation of gelatin/silicon and magnesium Co-doped fluorapatite nanocomposite coating applied on AZ31 Mg alloy. Russian J. Non-Ferrous Metal. 59(4), 458–464 (2018). https://doi.org/10.3103/S106782121804007710.3103/S1067821218040077 ↗
49. Jiang, B.L., Wang, Y.M.: Plasma electrolytic oxidation treatment of aluminium and titanium alloys. In: Surface Engineering of Light Alloys: Aluminium, Magnesium and Titanium Alloys, pp. 110–54. Elsevier Inc (2010)10.1533/9781845699451.2.110 ↗
50. Kamrani, S., Fleck, C.: Biodegradable Magnesium alloys as temporary orthopaedic implants: A review. Biometals 32(2), 185–193 (2019)10.1007/s10534-019-00170-y ↗
51. Khajuria, G., Gupta, V. Magnesium alloys for biomedical applications: Scope and opportunities. In: Magnesium Alloys for Biomedical Applications, pp. 1–19. CRC Press. (2024)10.1201/9781003400462-1 ↗
52. Kim, K.T., Eo, M.Y., Nguyen, T.T.H., Kim, S.M.: General review of titanium toxicity. Int. J. Implant Dent. 5, 1–12 (2019)10.1186/s40729-019-0162-x ↗
53. Laurindo, C.A.H., Bemben, L.M., Torres, R.D., Mali, S.A., Gilbert, J.L., Soares, P.: Influence of the annealing treatment on the Tribocorrosion properties of Ca and P containing TiO2 produced by plasma electrolytic oxidation. Mater. Technol. 31(12), 719–725 (2016). https://doi.org/10.1080/10667857.2016.122789510.1080/10667857.2016.1227895 ↗
54. Lemons, J.E., Lucas, L.C.: Properties of biomaterials. J. Arthroplast. 1(2), 143–147 (1986)10.1016/S0883-5403(86)80053-5 ↗
55. Lim, T.S., Ryu, H.S., Hong, S.H.: Electrochemical corrosion properties of CeO2-containing coatings on AZ31 magnesium alloys prepared by Plasma Electrolytic Oxidation. Corros. Sci. 62, 104–111 (2012). https://doi.org/10.1016/j.corsci.2012.04.04310.1016/j.corsci.2012.04.043 ↗
56. Liu, D., Ma, H., Liang, Y.: In vitro and in vivo biocompatibility and bio-tribological properties of the calcium/amorphous-C composite films for bone tissue engineering application. Colloids Surf. B 188, 110792 (2020)10.1016/j.colsurfb.2020.110792 ↗
57. Liu, F., Shan, D., Song, Y., Han, E.H., Ke, W.: Corrosion behavior of the composite ceramic coating containing zirconium oxides on AM30 magnesium alloy by plasma electrolytic oxidation. Corros. Sci. 53(11), 3845–3852 (2011). https://doi.org/10.1016/j.corsci.2011.07.03710.1016/j.corsci.2011.07.037 ↗
58. Li, Z., Yuan, Yi., Sun, P., Jing, X.: Ceramic coatings of LA141 alloy formed by plasma electrolytic oxidation for corrosion protection. ACS Appl. Mater. Interf. 3(9), 3682–3690 (2011). https://doi.org/10.1021/am200863s10.1021/am200863s ↗
59. Lu, X., Blawert, C., Huang, Y., Ovri, H., Zheludkevich, M.L., Kainer, K.U.: Plasma electrolytic oxidation coatings on Mg alloy with addition of SiO2 particles. Electrochim. Acta 187, 20–33 (2016)10.1016/j.electacta.2015.11.033 ↗
60. Lu, X., Blawert, C., Mohedano, M., Scharnagl, N., Zheludkevich, M.L., Kainer, K.U.: Influence of electrical parameters on particle uptake during plasma electrolytic oxidation processing of AM50 Mg alloy. Surf. Coat. Technol. 289, 179–185 (2016). https://doi.org/10.1016/j.surfcoat.2016.02.00610.1016/j.surfcoat.2016.02.006 ↗
61. Lu, X., Blawert, C., Zheludkevich, M.L., Kainer, K.U.: Insights into plasma electrolytic oxidation treatment with particle addition. Corros. Sci. 101, 201–207 (2015). https://doi.org/10.1016/j.corsci.2015.09.01610.1016/j.corsci.2015.09.016 ↗
62. Lu, X., Mohedano, M., Blawert, C., Matykina, E., Arrabal, R., Kainer, K.U., Zheludkevich, M.L.: Plasma electrolytic oxidation coatings with particle additions – a review. Surf. Coat. Technol. 307, 1165–1182 (2016)10.1016/j.surfcoat.2016.08.055 ↗
63. Madhankumar, A., Thangavel, E., Suresh Ramakrishna, I.B., Obot, H.C., Jung, K.S., Shin, Z.M., Gasem, H.K., Kim, D.E.: Multi-functional ceramic hybrid coatings on biodegradable AZ31 Mg implants: Electrochemical, tribological and quantum chemical aspects for orthopaedic applications. RSC Adv. 4(46), 24272–24285 (2014). https://doi.org/10.1039/c4ra02363c10.1039/c4ra02363c ↗
64. Mahapatro, A., Arshanapalli, S.A.: “Bioceramic coatings on magnesium alloys.” J. Bio- Tribo-Corrosion 3(3), (2017). https://doi.org/10.1007/s40735-017-0099-710.1007/s40735-017-0099-7 ↗
65. Miola, M., Verné, E., Ciraldo, F.E., Cordero-Arias, L., Boccaccini, A.R.: Electrophoretic deposition of chitosan/45S5 bioactive glass composite coatings doped with Zn and Sr. Front. Bioeng. Biotechnol. 3, 159 (2015)10.3389/fbioe.2015.00159 ↗
66. Misra, S.K., Mohn, D., Brunner, T.J., Stark, W.J., Philip, S.E., Roy, I., Salih, V., Knowles, J.C., Boccaccini, A.R.: Comparison of nanoscale and microscale bioactive glass on the properties of P(3HB)/Bioglass® composites. Biomaterials 29(12), 1750–1761 (2008). https://doi.org/10.1016/j.biomaterials.2007.12.04010.1016/j.biomaterials.2007.12.040 ↗
67. Mohedano, M., Blawert, C., Zheludkevich, M.L.: Silicate-based plasma electrolytic oxidation (PEO) coatings with incorporated CeO2 particles on AM50 magnesium alloy. Mater. Des. 86, 735–744 (2015). https://doi.org/10.1016/j.matdes.2015.07.13210.1016/j.matdes.2015.07.132 ↗
68. Molaei, M., Babaei, K., Fattah-alhosseini, A.: Improving the wear resistance of plasma electrolytic oxidation (PEO) coatings applied on Mg and its alloys under the addition of nano-and micro-sized additives into the electrolytes: A review. J. Magnesium Alloys 9(4), 1164–1186 (2021)10.1016/j.jma.2020.11.016 ↗
69. Monetta, T., Acquesta, A., Carangelo, A., Donato, N., Bellucci, F.: Durability of AZ31 magnesium biodegradable alloys polydopamine aided: Part 1. J. Magnesium Alloys 5(4), 412–422 (2017)10.1016/j.jma.2017.09.006 ↗
70. Monetta, T., Parnian, P., Acquesta, A.: Recent advances in the control of the degradation rate of PEO Treated magnesium and its alloys for biomedical applications. Metals 10(7), 1–18 (2020). https://doi.org/10.3390/met1007090710.3390/met10070907 ↗
71. Mori, Y., Koshi, A., Liao, J., Asoh, H., Ono, S.: Characteristics and corrosion resistance of plasma electrolytic oxidation coatings on AZ31B Mg alloy formed in phosphate - silicate mixture electrolytes. Corros. Sci. 88, 254–262 (2014). https://doi.org/10.1016/j.corsci.2014.07.03810.1016/j.corsci.2014.07.038 ↗
72. Nasiri Vatan, H., Ebrahimi-Kahrizsangi, R., Kasiri-Asgarani, M.: Structural, tribological and electrochemical behavior of SiC nanocomposite oxide coatings fabricated by plasma electrolytic oxidation (PEO) on AZ31 magnesium alloy. J. Alloy. Compd. 683, 241–255 (2016). https://doi.org/10.1016/j.jallcom.2016.05.09610.1016/j.jallcom.2016.05.096 ↗
73. Oliver, J.A.N., Yingchao, S., Xiaonan, L., Kuo, P.H., Jincheng, D., Zhu, D.: Bioactive glass coatings on metallic implants for biomedical applications. Bioact. Mater. 4, 261–70 (2019)
74. Qiao, L.P., Lou, J., Zhang, S.F., Qu, B., Chang, W.H., Zhang, R.F.: The entrance mechanism of calcium and phosphorus elements into micro arc oxidation coatings developed on Ti6Al4V alloy. Surf. Coat. Technol. 285, 187–196 (2016). https://doi.org/10.1016/j.surfcoat.2015.11.04110.1016/j.surfcoat.2015.11.041 ↗
75. Rahul, D., Singh, A., Jackson, M.J., Coelho, R.T., Prakash, D., Charalambous, C.P., Ahmed, W., da Silva, L.R.R., Lawrence, A.A.: A comprehensive review on metallic implant biomaterials and their subtractive manufacturing. Int. J. Adv. Manuf. Technol. 120(3), 1473–1530 (2022)
76. Rapheal, G., Kumar, S., Scharnagl, N., Blawert, C.: Effect of current density on the microstructure and corrosion properties of plasma electrolytic oxidation (PEO) coatings on AM50 Mg alloy produced in an electrolyte containing clay additives. Surf. Coat. Technol. 289, 150–164 (2016). https://doi.org/10.1016/j.surfcoat.2016.01.03310.1016/j.surfcoat.2016.01.033 ↗
77. Rikhari, B., Pugal Mani, S., Rajendran, N.: Polypyrrole/graphene oxide composite coating on Ti Implants: A promising material for biomedical applications. J. Mater. Sci. 55(12), 5211–5229 (2020). https://doi.org/10.1007/s10853-019-04228-710.1007/s10853-019-04228-7 ↗
78. Rizwan, M., Alias, R., Zaidi, U.Z., Mahmoodian, R., Hamdi, M.: Surface modification of valve metals using plasma electrolytic oxidation for antibacterial applications: A review. J. Biomed. Mater. Res. - Part A 106(2), 590–605 (2018)10.1002/jbm.a.36259 ↗
79. Rojaee, R., Fathi, M., Raeissi, K., Sharifnabi, A.: Biodegradation assessment of nanostructured fluoridated hydroxyapatite coatings on biomedical grade magnesium alloy. Ceram. Int. 40(9), 15149–58 (2014). https://doi.org/10.1016/j.ceramint.2014.06.12910.1016/j.ceramint.2014.06.129 ↗
80. Saji, V.S.: Electrophoretic (EPD) coatings for magnesium alloys. J. Ind. Eng. Chem. 103, 358–372 (2021). https://doi.org/10.1016/j.jiec.2021.08.00210.1016/j.jiec.2021.08.002 ↗
81. Samiee, M., Noori, A., Seyedraoufi, Z.S., Eshraghi, M.J.: Enhanced biocompatibility of biodegradable magnesium alloy modified by TiO2-MgO-GO coating. J. Aust. Ceram. Soc. (2023). https://doi.org/10.1007/s41779-023-00960-110.1007/s41779-023-00960-1 ↗
82. Sandhyarani, M., Ashfaq, M., Arunnellaiappan, T., Selvan, M.P., Subramanian, S., Rameshbabu, N.: Effect of electrical parameters on morphology and in-vitro corrosion resistance of plasma electrolytic oxidized films formed on zirconium. Surf. Coat. Technol. 269(1), 286–294 (2015). https://doi.org/10.1016/j.surfcoat.2015.03.00110.1016/j.surfcoat.2015.03.001 ↗
83. Sarraf, M., Sukiman, N.L., Bushroa, A.R., Nasiri-Tabrizi, B., Dabbagh, A., Abu Kasim, N.H., Basirun, W.J.: In vitro bioactivity and corrosion resistance enhancement of Ti-6Al-4V by highly ordered TiO 2 nanotube arrays. J. Aust. Ceram. Soc. 55(1), 187–200 (2019). https://doi.org/10.1007/s41779-018-0224-110.1007/s41779-018-0224-1 ↗
84. Selvakumar, N., Barshilia, H.C.: Review of physical vapor deposited (PVD) spectrally selective coatings for mid- and high-temperature solar thermal applications. Sol. Energy Mater. Sol. Cells 98, 1–23 (2012)10.1016/j.solmat.2011.10.028 ↗
85. Shim, G.: Factors influencing plasma electrolytic oxidation(PEO) coatings on magnesium alloys: A review. J. Korean Inst. Metals Mater. 55(5), 296–307 (2017). https://doi.org/10.3365/KJMM.2017.55.5.29610.3365/KJMM.2017.55.5.296 ↗
86. Silvello, A., Cavaliere, P., Yin, S., Lupoi, R., Garcia Cano, I., Dosta, S.: Microstructural, mechanical and wear behavior of HVOF and cold-sprayed high-entropy alloys (HEAs) coatings. J. Therm. Spray Technol. 31(4), 1184–1206 (2022)10.1007/s11666-021-01293-w ↗
87. Simchen, F., Sieber, M., Lampke, T.: Electrolyte influence on ignition of plasma electrolytic oxidation processes on light metals. Surf. Coat. Technol. 315, 205–213 (2017). https://doi.org/10.1016/j.surfcoat.2017.02.04110.1016/j.surfcoat.2017.02.041 ↗
88. Vijay, S., Dong, Shuai, Jun, T.R., Karim, G., Shrinivas, K., Haiyan, L., Cole Ivan, S., Jie, D., Xiaobo, C.: Plasma Electrolytic Oxidation upon Mg Alloys: Fundamentals, State-of-the-Art Progress and Challenges. In: Conversion Coatings for Magnesium and its Alloys, edited by T. S. N. and C. X. Saji Viswanathan S. and Sankara Narayanan, pp. 445–64. Cham: Springer International Publishing (2022)10.1007/978-3-030-89976-9_20 ↗
89. Staiger, M.P., Pietak, A.M., Huadmai, J., Dias, G.: Magnesium and its alloys as orthopedic biomaterials: A review. Biomaterials 27(9), 1728–1734 (2006)10.1016/j.biomaterials.2005.10.003 ↗
90. Steinberg, J., Shah, K.M., Gartland, A., Zeggini, E., Wilkinson, J.M.: Effects of chronic cobalt and chromium exposure after metal-on-metal hip resurfacing: An epigenome-wide association pilot study. J. Orthop. Res. 35(10), 2323–2328 (2017)10.1002/jor.23525 ↗
91. Stojadinović, S., Vasilić, R., Radić-Perić, J., Perić, M.: Characterization of plasma electrolytic oxidation of magnesium alloy AZ31 in alkaline solution containing fluoride. Surf. Coat. Technol. 273(1), 1–11 (2015). https://doi.org/10.1016/j.surfcoat.2015.03.03210.1016/j.surfcoat.2015.03.032 ↗
92. Sukuroglu, E.E., Farzi, H., Sukuroglu, S., Totik, Y., Arslan, E., Efeoglu, I.: The effect of plasma electrolytic oxidation process parameters on the tribocorrosion properties of TiO2 coatings. J. Adhes. Sci. Technol. 31(12), 1361–1373 (2017). https://doi.org/10.1080/01694243.2016.125663510.1080/01694243.2016.1256635 ↗
93. Tang, H., Gao, Y.: Preparation and characterization of hydroxyapatite containing coating on AZ31 magnesium alloy by micro-arc oxidation. J. Alloy. Compd. 688, 699–708 (2016). https://doi.org/10.1016/j.jallcom.2016.07.07910.1016/j.jallcom.2016.07.079 ↗
94. de la Hoz, T., Florencia, M., Katunar, M.R., González, A., Sanchez, A.G., Díaz, A.O., Ceré, S.: Effect of anodized zirconium implants on early osseointegration process in adult rats: A histological and histomorphometric study. Prog. Biomater. 8(4), 249–260 (2019). https://doi.org/10.1007/s40204-019-00124-010.1007/s40204-019-00124-0 ↗
95. Thirugnanam, T.: “Effect of polymers (PEG and PVP) on sol-gel synthesis of microsized zinc oxide.” J. Nanomater. 2013, (2013). https://doi.org/10.1155/2013/36217510.1155/2013/362175 ↗
96. Tsai, D.S., Tsai, Y.C., Chou, C.C.: Corrosion passivation of magnesium alloy with the duplex coatings of plasma electrolytic oxidation and tetrafluoroethylene-based polymers. Surf. Coat. Technol. 366, 15–23 (2019). https://doi.org/10.1016/j.surfcoat.2019.03.01510.1016/j.surfcoat.2019.03.015 ↗
97. Verdier, S., Boinet, M., Maximovitch, S., Dalard, F.: Formation, structure and composition of anodic films on AM60 magnesium alloy obtained by DC plasma anodising. Corros. Sci. 47(6), 1429–1444 (2005). https://doi.org/10.1016/j.corsci.2004.07.03810.1016/j.corsci.2004.07.038 ↗
98. White, L., Koo, Y., Neralla, S., Sankar, J., Yun, Y.: Enhanced mechanical properties and increased corrosion resistance of a biodegradable magnesium alloy by plasma electrolytic oxidation (PEO). Mater. Sci. Eng., B 208, 39–46 (2016). https://doi.org/10.1016/j.mseb.2016.02.00510.1016/j.mseb.2016.02.005 ↗
99. Williams, D.: Revisiting the definition of biocompatibility. Med. Device Technol. 14(8), 10–13 (2003)
100. Witte, F.: The history of biodegradable magnesium implants: A review. Acta Biomater. 6(5), 1680–1692 (2010)10.1016/j.actbio.2010.02.028 ↗