Detoxification of Sprayed Crocidolite
Source abstract
Abstract
Detoxification of crocidolite particles in sprayed crocidolite was performed by a combination of heating and grinding treatment. Crocidolite crystal was detected XRD analysis in the sample heated at temperatures below 800°C for 3 h, but not after heating at 900°C for 3 h. Although crocidolite crystal remained in the sample heated at the temperatures over 500°C, the crocidolite particles could be easily ground using a mortar to smaller than several micrometers in size, which is safe for the human body (below 8 μm). However, crocidolite crystals could not be detected using phase-contrast microscope after heating at temperatures higher than 500°C for 3 h.