article·2006-01-01Open access

Detoxification of Sprayed Crocidolite

Shinobu Hashimoto, Atsushi Okuda, Akira Kambayashi, Sawao Honda, Hideo Awaji, Koichiro Fukuda

Abstract

Detoxification of crocidolite particles in sprayed crocidolite was performed by a combination of heating and grinding treatment. Crocidolite crystal was detected XRD analysis in the sample heated at temperatures below 800°C for 3 h, but not after heating at 900°C for 3 h. Although crocidolite crystal remained in the sample heated at the temperatures over 500°C, the crocidolite particles could be easily ground using a mortar to smaller than several micrometers in size, which is safe for the human body (below 8 μm). However, crocidolite crystals could not be detected using phase-contrast microscope after heating at temperatures higher than 500°C for 3 h.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Advanced X-ray and CT Imaging · Building materials and conservation · Cultural Heritage Materials Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References

Reference metadata was not supplied for this record.