Dynamic Strength Evaluation of Ceramic Beams Containing Small Flaws
Source abstract
Abstract
A method for dynamic strength evaluation of ceramic beams containing small flaws was studied. (1) The critical frequency range was obtained with evaluating the strength of beams on the basis of the static-fatigue limit. (2) The critical frequency range increased slightly, with an increase of the equivalent crack length. (3) With an increase in the ratio of the breadth and depth, the eigenvalues increased, except for the fundamental eigenvalue. The eigenvalues increased monotonically, with an increase in the slenderness ratio and the stiffness of support. (4) For an increase in the damping ratio, the critical frequency range was constant, and then decreased. The fundamental critical frequency range was not affected by the damping ratio.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Concrete Corrosion and Durability · Structural Health Monitoring Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References
Reference metadata was not supplied for this record.