Abstract
Material properties of implants such as volume porosity and nanoscale surface modification have been shown to enhance cell-material interactions in vitro and osseointegration in vivo. Porous tantalum (Ta) and titanium (Ti) coatings are widely used for non-cemented implants, which are fabricated using different processing routes. In recent years, some of those implants are being manufactured using additive manufacturing. However, limited knowledge is available on direct comparison of additively manufactured porous Ta and Ti structures towards early stage osseointegration. In this study, we have fabricated porous Ta and Ti6Al4V (Ti64) implants using laser engineered net shaping (LENS™) with similar volume fraction porosity to compare the influence of surface characteristics and material chemistry on in vivo response using a rat distal femur model for 5 and 12 weeks. We have also assessed whether surface modification on Ti64 can elicit similar in vivo response as porous Ta in a rat distal femur model for 5 and 12 weeks. The harvested implants were histologically analyzed for osteoid surface per bone surface. Field emission scanning electron microscopy (FESEM) was done to assess the bone-implant interface. The results presented here indicate comparable performance of porous Ta and surface modified porous Ti64 implants towards early stage osseointegration at 5 weeks post implantation through seamless bone-material interlocking. However, a continued and extended efficacy of porous Ta is found in terms of higher osteoid formation at 12 weeks post-surgery.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Bone Tissue Engineering Materials · Titanium Alloys Microstructure and Properties · Orthopaedic implants and arthroplasty
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (40)
Show source-provided references
1. Development and applications of porous tantalum trabecular metal-enhanced titanium dental implants10.1111/cid.12059 ↗
2. Immediate placement of a porous-tantalum, trabecular metal-enhanced titanium dental implant with demineralized bone matrix into a socket with deficient buccal bone: a clinical report10.1016/j.prosdent.2014.09.022 ↗
3. Biologic performance of tantalum10.1016/0267-6605(94)90113-9 ↗
4. Evaluation of the osteogenesis and osseointegration of titanium alloys coated with graphene: an in vivo study10.1038/s41598-018-19742-y ↗
5. A comparison of micro-CT and histomorphometry for evaluation of osseointegration of PEO-coated titanium implants in a rat model10.1038/s41598-017-16465-4 ↗
6. In vivo study of osteogenerating properties of calcium-phosphate coating on titanium alloy Ti–6Al–4V
7. Characteristics of bone ingrowth and interface mechanics of a new porous tantalum biomaterial10.1302/0301-620X.81B5.0810907 ↗
8. Porous tantalum stimulates the proliferation and osteogenesis of osteoblasts from elderly female patients10.1002/jor.21251 ↗
9. Tantalum—a bioactive metal for implants10.1007/s11837-010-0110-y ↗
10. Bonding of alkali-and heat-treated tantalum implants to bone10.1002/(SICI)1097-4636(2000)53:1<28::AID-JBM4>3.0.CO;2-F ↗
11. Biocompatibility and osteogenesis of refractory metal implants, titanium, hafnium, niobium, tantalum and rhenium10.1016/S0142-9612(00)00275-1 ↗
12. The proliferation and phenotypic expression of human osteoblasts on tantalum metal10.1016/j.biomaterials.2003.09.005 ↗
13. Morphology, proliferation, and osteogenic differentiation of mesenchymal stem cells cultured on titanium, tantalum, and chromium surfaces10.1002/jbm.a.31602 ↗
14. Experimental and clinical performance of porous tantalum in orthopedic surgery10.1016/j.biomaterials.2006.04.041 ↗
15. Helsen · 2010
16. Direct laser processing of a tantalum coating on titanium for bone replacement structures10.1016/j.actbio.2009.11.021 ↗
17. Additive manufacturing of biomaterials
18. Effect of pore size on bone ingrowth into porous titanium implants fabricated by additive manufacturing: an in vivo experiment10.1016/j.msec.2015.10.069 ↗
19. In vivo performance of selective electron beam-melted Ti-6Al-4V structures10.1002/jbm.a.32337 ↗
20. Additively manufactured porous tantalum implants10.1016/j.actbio.2014.12.003 ↗
21. Bone regeneration performance of surface-treated porous titanium10.1016/j.biomaterials.2014.04.054 ↗
22. Influence of porosity on mechanical properties and in vivo response of Ti6Al4V implants10.1016/j.actbio.2009.11.011 ↗
23. Processing and biocompatibility evaluation of laser processed porous titanium10.1016/j.actbio.2007.05.009 ↗
24. Porous tantalum structures for bone implants: fabrication, mechanical and in vitro biological properties10.1016/j.actbio.2010.01.046 ↗
25. Review of titania nanotubes: fabrication and cellular response10.1016/j.ceramint.2012.03.002 ↗
26. Titanium dioxide nanotubes enhance bone bonding in vivo10.1002/jbm.a.32463 ↗
27. Improved bone-forming functionality on diameter-controlled TiO2 nanotube surface10.1016/j.actbio.2009.05.008 ↗
28. TiO2 nanotubes on Ti: influence of nanoscale morphology on bone cell–materials interaction10.1002/jbm.a.32088 ↗
29. Surface modification of titanium for load-bearing applications10.1007/s10856-008-3418-1 ↗
30. In vivo response of laser processed porous titanium implants for load-bearing implants10.1007/s10439-016-1673-8 ↗
31. Surface modification of laser-processed porous titanium for load-bearing implants10.1016/j.scriptamat.2008.06.018 ↗
32. Direct laser sintering of iron–graphite powder mixture10.1016/j.msea.2004.05.070 ↗
33. Bose · 2017
34. Utilizing micro-computed tomography to evaluate bone structure surrounding dental implants: a comparison with histomorphometry10.1002/jbm.b.32938 ↗
35. Bone histomorphometry: standardization of nomenclature, symbols, and units: report of the ASBMR Histomorphometry Nomenclature Committee10.1002/jbmr.5650020617 ↗
36. Heat transfer and fluid flow during keyhole mode laser welding of tantalum, Ti–6Al–4V, 304L stainless steel and vanadium10.1088/0022-3727/40/18/037 ↗
37. Laser processing of bulk Al–12Si alloy: influence of microstructure on thermal properties10.1080/14786435.2010.526650 ↗
38. Influence of engineered titania nanotubular surfaces on bone cells10.1016/j.biomaterials.2007.03.020 ↗
39. The role of implant surface characteristics in the healing of bone10.1177/10454411960070040301 ↗
40. Mechanical biocompatibilities of titanium alloys for biomedical applications10.1016/j.jmbbm.2007.07.001 ↗