Effect of chemical–electrochemical surface treatment on the roughness and fatigue performance of porous titanium lattice structures
Source abstract
Abstract
Additive manufacturing (AM) has enabled the fabrication of extremely complex components such as porous metallic lattices, which have applications in aerospace, automotive, and in particular biomedical devices. The fatigue resistance of these materials is currently an important limitation however, due to manufacturing defects such as semi-fused particles and weld lines. In this work a chemical–electrochemical surface treatment (Hirtisation®) is used for post-processing of Ti-6Al-4V lattices, reducing the strut surface roughness (Sa) from 12 to 6 μm, removing all visible semi-fused particles. The evenness of this treatment in lattices with relative density up to 18.3% and treatment depth of 6.5 mm was assessed, finding no evidence of reduced effectiveness on internal surfaces. After normalising to quasi-static mechanical properties to account for material losses during hirtisation (34%–37% reduction in strut diameter), the fatigue properties show a marked improvement due to the reduction in surface roughness. Normalised high cycle fatigue strength increased from around 0.1 to 0.16-0.21 after hirtisation, an average increase of 80%. For orthopaedic implant devices where matching the stiffness of surrounding bone is crucial, the fatigue strength to modulus ratio is a key metric. After hirtisation the fatigue strength to modulus ratio increased by 90%, enabling design of stiffness matched implant materials with greater fatigue strength. This work demonstrates that hirtisation is an effective method for improving the surface roughness of porous lattice materials, thereby enhancing their fatigue performance.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Bone Tissue Engineering Materials · Additive Manufacturing Materials and Processes · Additive Manufacturing and 3D Printing Technologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (42)
Show source-provided references
1. Additive manufacturing for aerospace flight applications10.2514/1.A33544 ↗
2. Review on design and structural optimisation in additive manufacturing: Towards next-generation lightweight structures10.1016/j.matdes.2019.108164 ↗
3. Energy absorption diagram characteristic of metallic self-supporting 3D lattices fabricated by additive manufacturing and design method of energy absorption structure
4. Topological design and additive manufacturing of porous metals for bone scaffolds and orthopaedic implants: A review10.1016/j.biomaterials.2016.01.012 ↗
5. Topological design, permeability and mechanical behavior of additively manufactured functionally graded porous metallic biomaterials10.1016/j.actbio.2018.12.013 ↗
6. The design and in vivo testing of a locally stiffness-matched porous scaffold10.1016/j.apmt.2019.02.017 ↗
7. Long-term implant fixation and stress-shielding in total hip replacement10.1016/j.jbiomech.2014.12.021 ↗
8. A study of the microstructural evolution during selective laser melting of Ti-6Al-4V10.1016/j.actamat.2010.02.004 ↗
9. Analysis of defect generation in Ti-6Al-4V parts made using powder bed fusion additive manufacturing processes
10. Effect of process parameters on the generated surface roughness of down-facing surfaces in selective laser melting10.3390/app9061256 ↗
11. Application of mechanical surface finishing processes for roughness reduction and fatigue improvement of additively manufactured Ti-6Al-4V parts10.1016/j.ijfatigue.2017.05.008 ↗
12. Ti-6Al-4V additively manufactured by selective laser melting with superior mechanical properties10.1007/s11837-015-1297-8 ↗
13. Critical assessment of the fatigue performance of additively manufactured Ti-6Al-4V and perspective for future research10.1016/j.ijfatigue.2015.12.003 ↗
14. Vacuum heat treatments of titanium porous structures
15. Effects of build orientation and heat treatment on the microstructure and mechanical properties of selective laser melted Ti6Al4V lattice structures
16. The influence of chemical polishing of titanium scaffolds on their mechanical strength and in-vitro cell response10.1016/j.msec.2018.04.019 ↗
17. Improving the mechanical efficiency of electron beam melted titanium lattice structures by chemical etching
18. Geometrical control of lattice structures produced by EBM through chemical etching: Investigations at the scale of individual struts10.1016/j.matdes.2016.08.029 ↗
19. Fatigue performances of chemically etched thin struts built by selective electron beam melting: Experiments and predictions
20. Surface roughness and morphology customization of additive manufactured open porous Ti6Al4V structures10.3390/ma6104737 ↗
21. Continuous and pulsed selective laser melting of Ti6Al4V lattice structures: Effect of post-processing on microstructural anisotropy and fatigue behaviour
22. Hansal · 2023
23. Effect of chemical post-processing on surfaces and sub-surface defects in electron beam melted Ti-6Al-4V10.1016/j.matchar.2022.112281 ↗
24. G. Kerckhofs, G. Pyka, M. Moesen, J. Schrooten, M. Wevers, High-resolution micro-CT as a tool for 3D surface roughness measurement of 3D additive manufactured porous structures, in: Proceedings ICT 2012, International Conference on Industrial Computed Tomography, 2012, pp. 77–83.10.1002/adem.201200156 ↗
25. High-resolution microfocus X-Ray computed tomography for 3D surface roughness measurements of additive manufactured porous materials10.1002/adem.201200156 ↗
26. X-Ray microcomputed tomography in additive manufacturing: A review of the current technology and applications10.1089/3dp.2018.0060 ↗
27. StrutSurf: A tool for analysis of strut morphology and surface roughness in additively manufactured lattices10.1016/j.softx.2022.101043 ↗
28. The influence of laser parameters and scanning strategies on the mechanical properties of a stochastic porous material10.1016/j.matdes.2017.06.041 ↗
29. Controlling and testing anisotropy in additively manufactured stochastic structures
30. International Organization for Standardization · 2011
31. Fiji: An open-source platform for biological-image analysis
32. International Organization for Standardization · 2017
33. International Organization for Standardization · 2003
34. From microstructural design to surface engineering: A tailored approach for improving fatigue life of additively manufactured meta-biomaterials10.1016/j.actbio.2018.10.043 ↗
35. Surface modification of Ti6Al4V open porous structures produced by additive manufacturing10.1002/adem.201100344 ↗
36. The effect of spinal instrumentation particulate wear debris: an in vivo rabbit model and applied clinical study of retrieved instrumentation cases10.1016/S1529-9430(02)00443-6 ↗
37. Titanium, chromium and cobalt ions modulate the release of bone-associated cytokines by human monocytes/macrophages in vitro10.1016/0142-9612(96)00072-5 ↗
38. The effects on bone cells of metal ions released from orthopaedic implants. A review
39. Wear particles, periprosthetic osteolysis and the immune system10.1016/j.biomaterials.2007.06.035 ↗
40. Impact of tribocorrosion and titanium particles release on dental implant complications — A narrative review10.1016/j.jdsr.2021.09.001 ↗
41. Mechanical and morphological properties of additively manufactured SS316L and Ti6Al4V micro-struts as a function of build angle
42. Controlling the mechanical behaviour of stochastic lattice structures: The key role of nodal connectivity