journal article·2015-10

Mechanical properties and microstructure of removable partial denture clasps manufactured using selective laser melting

S. Yager, J. Ma, H. Ozcan, H.I. Kilinc, A.H. Elwany, I. Karaman

Publisher page

Abstract

Abstract This study compares the mechanical response and microstructure of Co–Cr–Mo removable partial denture models made through conventional lost-wax casting and the selective laser melting additive manufacturing process. Co–Cr–Mo clasps for removal partial dentures, based on a wax model (BEGO USA), were fabricated through lost-wax technique and selective laser melting, and subjected to mechanical bending experiments to determine their yield strength and maximum reversible deformation. Single-Factor Analysis of Variance (ANOVA) was used to compare data from the two populations. Microstructure and chemical composition of the clasps were determined through scanning electron microscopy and wave-dispersive spectroscopy to rationalize the differences and similarities in the mechanical testing results from the two groups. It was found that the clasps made using lost-wax technique and selective laser melting exhibit comparable mean yield strengths and maximum elastic deformations, however the underlying microstructure of the cast clasps vastly differs from the laser-melted counterparts. Furthermore, the laser melted clasps exhibit larger variability in their mechanical response. While selective laser melting is capable of producing removable partial denture clasps with similar average mechanical responses to those of lost-wax cast counterparts, additional studies should be conducted to minimize the variability in the laser melted clasps in order to minimize unexpected failures.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Additive Manufacturing Materials and Processes · Dental materials and restorations · Welding Techniques and Residual Stresses

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (31)

Show source-provided references
1. ASTM Standard F2792, 2012a · 2012
2. Wohlers Associates · 2014
3. The application of rapid prototyping in prosthodontics10.1111/j.1532-849X.2012.00888.x ↗
4. Present status of titanium removable dentures – a review of the literature10.1111/j.1365-2842.2007.01821.x ↗
5. Edwab · 2003
6. A preliminary report of designing removable partial denture frameworks using a specifically developed software package
7. Use of CAD/CAM technology to fabricate a removable partial denture framework10.1016/j.prosdent.2006.05.029 ↗
8. A technique for fabricating patterns for removable partial denture frameworks using digitized casts and electronic surveying10.1016/j.prosdent.2003.10.002 ↗
9. Rapid manufacture of removable partial denture frameworks10.1108/13552540610652438 ↗
10. A review on process monitoring and control in metal-based additive manufacturing10.1115/1.4028540 ↗
11. Microstructures and mechanical behavior of Inconel 718 fabricated by selective laser melting10.1016/j.actamat.2011.12.032 ↗
12. Novel use of an aerospace selective laser sintering machine for rapid prototyping of an orbital blowout fracture10.1016/j.ijom.2009.12.002 ↗
13. High density selective laser melting of Waspaloy®10.1016/j.jmatprotec.2007.04.117 ↗
14. Additive manufacturing by selective laser melting the realizer desktop machine and its application for the dental industry10.1016/j.phpro.2010.08.082 ↗
15. Wehmöller · 2005 · vol. 1281 · 690
16. Evaluation of the mechanical properties and porcelain bond strength of cobalt-chromium dental alloy fabricated by selective laser melting10.1016/j.prosdent.2013.09.011 ↗
17. The evolution of rapid prototyping in dentistry: a review10.1108/13552540910961946 ↗
18. The analysis of the mechanical properties of F75 Co–Cr alloy for use in selective laser melting (SLM) manufacturing of removable partial dentures (RPD)
19. Microstructures and mechanical properties of Co–29Cr–6Mo alloy fabricated by selective laser melting process for dental applications10.1016/j.jmbbm.2013.01.021 ↗
20. Effects of cooling rate control during the solidification process on the microstructure and mechanical properties of cast Co–Cr–Mo alloy used for surgical implants10.1007/BF01107415 ↗
21. The effects of shape and size on investment heating and cooling rates
22. Comparison of cast Ti–Ni alloy clasp retention with conventional removable partial denture clasps10.1016/j.prosdent.2004.02.015 ↗
23. ASTM Standard F75, 2012a · 2012
24. 1985
25. Effect of carbon addition on microstructure and mechanical properties of a wrought Co–Cr–Mo implant alloy10.2320/matertrans.47.287 ↗
26. Microstructure of selective laser melted nickel–titanium10.1016/j.matchar.2014.05.017 ↗
27. The origin of microstructural diversity, texture, and mechanical properties in electron beam melted Ti-6Al-4V10.1007/s11661-010-0397-x ↗
28. The deformation and ageing of mild steel: III discussion of results10.1088/0370-1301/64/9/303 ↗
29. The cleavage strength of polycrystals
30. Technological restrictions of lightweight lattice structures manufactured by selective laser melting of metals
31. NIST · 2013