A Very Simple Method for Detection of Bisphenol A in Environmental Water by Heme Signal Amplification
Source abstract
Abstract
The detection of bisphenol A (BPA) was carried out using several simplified electrochemical sensors in which electroactive materials Heme, dopamine (DA), β -cyclodextrins ( β -CD) or Fc-ECG were deposited on screen-printed electrodes (SPEs) through one-step. The preparation of the developed sensors were verified by SEM, CV and DPV. Results shown that Heme/SPE sensor demonstrated notable electro-catalytic capabilities and a greater current response than other sensors for BPA detection and optimal operating conditions were determined. The current response vs concentration of BPA showed a linear relationship in the range of 0.05–0.50 μ mol·l −1 , the concentration limit of detection (S/N = 3) as 5.0 nmol·l −1 and 0.0013 μ A· μ M −1 ·cm −2 as the sensitivity of detection. There were no interferences arising from common elements that relate to BPA. Heme/SPE was applied for BPA detection in bottle drinking water, tap water and lake water; findings showed a total R.S.D. of less than 3.1% and average recovery from 95.0 to 104.0%. These results showed that the actual application of BPA detection was rapid and precise when placed in environmental water and even useful for safety verification.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Effects and risks of endocrine disrupting chemicals · Electrochemical Analysis and Applications · Advanced Chemical Sensor Technologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (47)
Show source-provided references
1. Yan · Anal. Chem. · 2001 · 73 · 527210.1021/ac015516v ↗
2. Galai · J. Electrochem. Soc. · 2020 · 16710.1149/1945-7111/ab6283 ↗
3. Zhang · Chinese J. Anal. Chem. · 2009 · 37 · 104110.1002/cjoc.201900298 ↗
4. Inoue · J. Chromatogr. B · 2000 · 749 · 1710.1016/S0378-4347(00)00351-0 ↗
5. Rahman · Biosens. Bioelectron. · 2007 · 22 · 246410.1016/j.bios.2006.09.010 ↗
6. Wang · Anal. Chim. Acta · 2009 · 638 · 2310.1016/j.aca.2009.02.013 ↗
7. Alkasir · Biosens. Bioelectron. · 2010 · 26 · 4310.1016/j.bios.2010.05.001 ↗
8. Choi · Mol. Cryst. Liq. Cryst. · 2010 · 519 · 3610.1080/15421400903579911 ↗
9. Yin · J. Hazard. Mater. · 2010 · 174 · 23610.1016/j.jhazmat.2009.09.041 ↗
10. Yin · Microchim. Acta · 2010 · 170 · 9910.1007/s00604-010-0396-z ↗
11. Dupuis · Environ. Sci. Pollut. Res. · 2012 · 19 · 419310.1007/s11356-012-0972-3 ↗
12. Watanabe · J. Chromatogr. B · 2001 · 762 · 110.1016/S0378-4347(01)00287-0 ↗
13. Li · Chromatographia · 2017 · 80 · 118910.1007/s10337-017-3332-0 ↗
14. Alnaimat · Microchem. J. · 2019 · 147 · 59810.1016/j.microc.2019.03.026 ↗
15. Nicolucci · Anal. Bioanal. Chem. · 2013 · 405 · 913910.1007/s00216-013-7342-y ↗
16. Wang · Anal. Sci. · 2017 · 33 · 77710.2116/analsci.33.777 ↗
17. Zhu · J. Electrochem. Soc. · 2017 · 164 · H54510.1149/2.0041709jes ↗
18. Yao · J. Chromatogr. B · 2018 · 1080 · 5010.1016/j.jchromb.2018.02.013 ↗
19. Lei · Pigm Resin Technol · 2018 · 47 · 3810.1108/PRT-03-2017-0022 ↗
20. Yu · Electrochim. Acta · 2011 · 56 · 905610.1016/j.electacta.2011.05.135 ↗
21. Li · Sensor Actuat B-Chem · 2012 · 171 · 72610.1016/j.snb.2012.05.063 ↗
22. Mazzotta · Anal Bioanal Chem. · 2013 · 405 · 358710.1007/s00216-013-6723-6 ↗
23. Gugoasa · J. Electrochem. Soc. · 2019 · 16710.1149/2.0062003JES ↗
24. Dong · Sensors-Basel · 2017 · 17 · 83610.3390/s17040836 ↗
25. Zhang · Chin. Chem. Lett. · 2014 · 25 · 51710.1016/j.cclet.2013.12.020 ↗
26. Zhu · J. Electrochem. Soc. · 2019 · 16610.1149/2.1381915jes ↗
27. Staden · J. Electrochem. Soc. · 2019 · 166 · B90310.1149/2.0521912jes ↗
28. Yao · J. Electrochem. Soc. · 2019 · 16610.1149/2.1481912jes ↗
29. Wu · J. Electrochem. Soc. · 2019 · 166 · B56210.1149/2.0141908jes ↗
30. Zhou · J. Electrochem. Soc. · 2018 · 165 · H96210.1149/2.1071814jes ↗
31. Zhou · J. Electrochem. Soc. · 2015 · 162 · B29810.1149/2.0021512jes ↗
32. Wang · J. Electrochem. Soc. · 2018 · 165 · B81410.1149/2.0401816jes ↗
33. Xu · J. Electrochem. Soc. · 2017 · 16410.1149/2.0021705jes ↗
34. Ma · J. Electrochem. Soc. · 2015 · 162 · H81610.1149/2.0081512jes ↗
35. He · Anal. Bioanal. Chem. · 2017 · 409 · 179710.1007/s00216-016-0123-7 ↗
36. Deiminiat · Sensor Actuat B-Chem · 2017 · 242 · 15810.1016/j.snb.2016.11.041 ↗
37. Niu · Anal. Methods-Uk · 2018 · 10 · 475010.1039/C8AY01705K ↗
38. Feng · Sensors-Basel · 2019 · 19 · 26810.3390/s19020268 ↗
39. Han · Sensor Actuat B-Chem · 2019 · 282 · 13010.1016/j.snb.2018.11.042 ↗
40. Kanagavalli · Electroanal · 2018 · 30 · 44510.1002/elan.201700596 ↗
41. Zhang · Sensor Actuat B-Chem · 2018 · 261 · 42510.1016/j.snb.2018.01.170 ↗
42. Santana · Sensor Actuat B-Chem · 2017 · 240 · 48710.1016/j.snb.2016.09.003 ↗
43. Cao · Biosens. Bioelectron. · 2017 · 92 · 8710.1016/j.bios.2017.02.002 ↗
44. Cao · Sensor Actuat B-Chem · 2017 · 252 · 4410.1016/j.snb.2017.05.148 ↗
45. Liu · Sensor Actuat B-Chem · 2018 · 266 · 24610.1016/j.snb.2018.03.116 ↗
46. Deng · Sensor Actuat B-Chem · 2019 · 286 · 41510.1016/j.snb.2019.01.137 ↗
47. Su · Anal. Bioanal. Chem. · 2018 · 410 · 188510.1007/s00216-017-0801-0 ↗