Resolving the three-dimensional flow field within commercial metal additive manufacturing machines: Application of experimental Magnetic Resonance Velocimetry
Source abstract
Abstract
In laser-based powder bed fusion of metals (PBF-LB/M) systems, the shielding gas flow is important for controlling the accumulation of melting byproducts such as soot and ejecta near the melt pool as well as sweeping ejecta, agglomerates, and “flying” powder away from the build region. It is necessary to understand the flow field throughout the build chamber in order to sufficiently control these contaminants to prevent their interference with delivered laser power and maintain part quality. A measurement technique called Magnetic Resonance Velocimetry (MRV) was applied to measure the entire three-dimensional three-component mean velocity field in a scaled flow model of a commercial EOS M290 PBF-LB/M build chamber. Flow conditions in the model were at a Reynolds number of 36000 (based on the average bulk velocity in the supply duct and its diameter) comparable to conditions in the full size M290. MRV measurements reveal five large jets issuing from the upper vent of the M290: the top jet supplies fresh gas flow across the optics keeping them clean, three jets issue horizontally, and the last jet travels downward impinging on the center of the build plate potentially sweeping contaminants toward the exit or delivering contaminants to the surface from the upper portion of the chamber. The lower vent supplies flow across the build plate, but this flow issues from above the build plate creating a backward facing step flow in which a region of separation with backwards flow exists. The backwards flow extends several centimeters over the edge of the build plate nearest to the vent before the inlet flow “attaches” to the build plate and proceeds to the exit. Single layer laser scans on individual titanium plates spaced uniformly around the build surface are performed, and their melt pool depths are measured as an indication of delivered laser power. Measured depths for plates in the separated flow region are measured to be 23 % shallower than in the central region of the build plate where the flow is unidirectional toward the exit. The influence of the shielding gas flow on melt pool depth is demonstrated using an extra vent placed below the lower vent to supply unidirectional flow across the build plate in the separated flow region. With the flow improvement, the melt pool depths increased by 15 %. These experiments support arguments that shielding gas flow is important for building consistent high quality parts and demonstrate the utility of MRV measurements for investigating, understanding, and potentially improving the shielding gas flows in PBF-LB/M systems.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Additive Manufacturing Materials and Processes · Laser Material Processing Techniques · Heat Transfer Mechanisms
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (32)
Show source-provided references
1. Influence of the shielding gas flow on the removal of process by-products in the selective laser melting process
2. A. Philo, N. Lavery, S.G.R. Brown, J. Cherry, J. Sienz, J. Joannou, C. Sutcliffe. (2015), Comparison and validation of gas flow models in a powder bed selective laser melting process, in Gill, A.J. and Sevilla, R. (Eds), Proceedings of The 23rd UK Conference of the Association for Computational Mechanics in Engineering, University of Swansea, pp. 189–192.
3. A. Philo, C. Sutcliffe, S. Sillars, J. Sienz, S. Brown, N. Lavery. (2017) A study into the effects of gas flow inlet design of the Renishaw AM250 laser powder bed fusion machine using computational modelling. Solid Freeform Fabrication 2017: Proceedings of the 28th Annual International Solid Freeform Fabrication Symposium-An Additive Manufacturing Conference, SFF 2017, pp 1203–1219.
4. Visualization of the shielding gas flow in SLM machines by space-resolved thermal anemometry10.1108/RPJ-07-2017-0149 ↗
5. Inert gas flow speed measurements in laser powder bed fusion additive manufacturing
6. Effect of plume on weld penetration during high-power fiber laser welding10.2351/1.4940148 ↗
7. Gas flow effects on selective laser melting (SLM) manufacturing performance. Journal of Materials 17 This publication is available free of charge from10.1016/j.jmatprotec.2011.09.020 ↗
8. Selective laser melting of AlSi10Mg: effects of scan direction, part placement and inert gas flow velocity on tensile strength10.1016/j.jmatprotec.2016.10.015 ↗
9. Influence of gas flow speed on laser plume attenuation and powder bed particle pickup in laser powder bed fusion10.1007/s11837-020-04020-y ↗
10. D.C. Deisenroth, J. Neira, J. Weaver, H. Yeung. (2020) Effects of Shield Gas Flow on Meltpool Variability and Signature in Scanned Laser Melting. ASME 2020 15th International Manufacturing Science and Engineering Conference, (V001T01A017). https://doi.org/10.1115/msec2020–8410.10.1115/MSEC2020-8410 ↗
11. On the effect of shielding gas flow on porosity and melt pool geometry in laser powder bed fusion additive manufacturing
12. Spatial inhomogeneity of build defects across the build plate in laser powder bed fusion
13. Magnetic resonance velocimetry: applications of magnetic resonance imaging in the measurement of fluid motion10.1007/s00348-007-0383-2 ↗
14. Recent advances in flow MRI10.1016/j.jmr.2012.11.022 ↗
15. Turbulent transport in an inclined jet in cross-flow10.1016/j.ijheatfluidflow.2013.06.001 ↗
16. Effects of varying reynolds number, blowing ratio, and internal geometry on trailing edge cutback film cooling10.1007/s00348-012-1260-1 ↗
17. Experimental based redesigns for trailing edge film cooling of gas turbine blades10.1115/1.4007601 ↗
18. Detailed velocity and heat transfer measurements of an advanced insert for impingement cooling10.1016/j.ijheatmasstransfer.2021.122066 ↗
19. Full-field flow measurements and heat transfer of a compact jet impingement array with local extraction of spent fluid10.1115/1.3109991 ↗
20. Experimental study of flow inside a centrifugal fan using magnetic resonance velocimetry
21. Magnetic resonance imaging measurements of scalar dispersion for a scaled urban transient release
22. Flow inside a coral colony measured using magnetic resonance velocimetry10.4319/lo.2009.54.5.1819 ↗
23. C.J. Elkins, A.S. Iyengar, M.T. Draney, M.D. Dake, F. Medina, R.B. Wicker, "Rapid In-Vitro MRV and PIV Measurements in Anatomically Accurate Human Thoracic Aorta Phantoms," 2005 ASME Summer Bioengineering Conference, June 22–26, Vail Cascade Resort, Vail, Colorado.
24. In vitro assessment of right ventricular outflow tract anatomy and valve orientation on bioprosthetic pulmonary valve hemodynamics
25. Three-dimensional inspiratory flow in the upper and central human airways10.1007/s00348-015-1966-y ↗
26. Transport and dispersion of particle-laden streaks in a standardized human nasal geometry10.1007/s00348-020-2878-z ↗
27. Magnetic resonance: Ongoing and future role in chemical engineering research10.1002/aic.690490102 ↗
28. 4D Magnetic resonance velocimetry for mean velocity measurements in complex turbulent flows10.1007/s00348-003-0587-z ↗
29. Effect of local gas flow in full penetration laser beam welding with high welding speeds10.3390/app10051867 ↗
30. A comprehensive study on meltpool depth in laser-based powder bed fusion of Inconel 71810.1007/s00170-021-08618-7 ↗
31. Influence of the Inert Gas Flow on the Laser Powder Bed Fusion (LPBF) Process
32. Toward a common laser powder bed fusion qualification test artifact