Automated thresholding method for the computed tomography inspection of the internal composition of parts fabricated using additive manufacturing
Source abstract
Abstract
Abstract This study presents an automated thresholding method for analyzing and quantifying the internal composition of additive manufacturing (AM) parts using computed tomography (CT) data. A mixed skewed-Gaussian distribution (MSGD) algorithm, derived from a statistical image analysis technique called Mixed Gaussian Distribution (MGD) clustering, integrates a mixture of skewed-Gaussian distributions to model the internal phases from CT data. The parameters of the MSGD algorithm (i.e. probability, mean, standard deviation, and skew) are inferred from the measured grayscale histogram using least-squares fitting and are assigned to phases present in the CT data. Upon fitting, the MSGD technique guides the thresholding of phases in CT data. From the MSGD fitted and thresholded CT data, phase volume percentages and spatial variations of density of the phases are quantified. The MSGD algorithm was validated using previously reported CT analysis and experimental porosity measurements of two Cobalt Chrome (CoCr) specimens (∼1 % and ∼13 % porosity) fabricated by powder bed fusion (PBF). Compared with the 1.1 % and 13.7 % porosity of the specimens measured by the Archimedes method, the MSGD method predicted a porosity of 1.6 % +/− 0.7 % and 14.5 % +/− 1.9 %, a measured increase of 0.5 % and 0.8 %, respectively. These results show a similarity in predicted porosity between Archimedes and MSGD method indicating that CT and the MSGD method may provide a reasonable estimate for part porosity.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Additive Manufacturing Materials and Processes · Additive Manufacturing and 3D Printing Technologies · Advanced X-ray and CT Imaging
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (30)
Show source-provided references
1. X-ray microcomputed tomography in additive manufacturing: a review of the current technology and applications, 3D print
2. Standard method for microCT-based additive manufacturing quality control 1: porosity analysis10.1016/j.mex.2018.09.005 ↗
3. Standard method for microCT-based additive manufacturing quality control 2: density measurement10.1016/j.mex.2018.09.006 ↗
4. Standard method for microCT-based additive manufacturing quality control 3: surface roughness10.1016/j.mex.2018.09.004 ↗
5. Standard method for microCT-based additive manufacturing quality control 4: metal powder analysis10.1016/j.mex.2018.10.021 ↗
6. Standardized X-ray tomography testing of additively manufactured parts: a round robin test
7. Kastner · 2010 · 1
8. X-ray computed tomography of polymer composites10.1016/j.compscitech.2017.10.023 ↗
9. Quantitative X-ray tomography10.1179/1743280413Y.0000000023 ↗
10. Computation of permeability of a non-crimp carbon textile reinforcement based on X-ray computed tomography images10.1016/j.compositesa.2015.11.025 ↗
11. Micro-CT-based improvement of geometrical and mechanical controllability of selective laser melted Ti6Al4V porous structures10.1016/j.msea.2011.06.045 ↗
12. High-resolution microfocus X-ray computed tomography for 3D surface roughness measurements of additive manufactured porous materials10.1002/adem.201200156 ↗
13. Porosity measurements and analysis for metal additive manufacturing process control10.6028/jres.119.019 ↗
14. Investigation of pore structure in cobalt chrome additively manufactured parts using X-ray computed tomography and three-dimensional image analysis
15. Dynamic thresholding of grey-level images
16. Nano-CT characterization of structural voids and air bubbles in fused deposition modeling for additive manufacturing
17. CT for additive manufacturing process characterisation: assessment of melt strategies on defect population
18. Kak · 2001 · 33
19. Case Studies in Nondestructive Testing and Evaluation High resolution pore size analysis in metallic powders by X-ray tomography10.1016/j.csndt.2016.09.002 ↗
20. Additive manufacturing powder feedstock characterization using X-ray tomography10.1016/j.mprp.2018.01.002 ↗
21. Artefacts in X-ray microtomography of materials10.1179/174328406X114117 ↗
22. A threshold selection method from gray-level histograms10.1109/TSMC.1979.4310076 ↗
23. A new method for gray-level picture thresholding using the entropy of the histogram10.1016/0734-189X(85)90125-2 ↗
24. Sezgin · 2004 · 13 · 146
25. The EM/MPM algorithm for segmentation of textured images: analysis and further experimental results10.1109/83.869185 ↗
26. Minimum error thresholding10.1016/0031-3203(86)90030-0 ↗
27. Some experiments on variable thresholding10.1016/0031-3203(79)90006-2 ↗
28. Bayes estimation subject to uncertainty about parameter constraints10.1093/biomet/63.1.201 ↗
29. Ross · 2011
30. Computed tomography evaluation of the porosity and fiber orientation in a short carbon fiber material extrusion filament and part