journal article·2024-01

Effect of designed pore size on electrochemical, wear, and tribocorrosion behavior of additively manufactured Ti-6Al-4V lattice structures

Guilherme Arthur Longhitano, Ignacio Manuel García, María Angeles Arenas, Juan José de Damborenea, Rubens Maciel Filho, Ana Conde

Publisher page

Abstract

The advent of additive manufacturing has been a disruptive technology in various fields, including medicine. One of the main causes of orthopedic implant failure is the mismatch between the implant material and the bone, causing bone resorption and aseptic loosening. In this regard, the use of additively manufactured lattice structures as orthopedic implant material has several advantages, such as producing a material with an adequate stiffness match with bone. Nevertheless, its behavior in service is not fully understood: the human body is a complex environment, and an orthopedic implant material is subjected to corrosion, wear, and tribocorrosion. In this work, Ti-6Al-4V solid and lattice structured samples were designed with pore sizes of 500, 700, and 900 µm and produced by PBF-EB. Microstructural and geometrical characterization was made on produced samples. The effect of pore sizes was analyzed under corrosion, wear, and tribocorrosion conditions, and compared with solid bulk samples. During corrosion tests, porous samples presented pitting attacks at high potentials, as the solid samples did not. The porous and solid samples presented similar behaviors under wear and tribocorrosion, with abrasive and adhesive wear as the predominant mechanism, and no statistical difference in the specific wear rates was found.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Titanium Alloys Microstructure and Properties · Orthopaedic implants and arthroplasty · Bone Tissue Engineering Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (70)

Show source-provided references
1. Global Orthopedic Devices Market Size Report, 2030, https://www.grandviewresearch.com/industry-analysis/orthopedic-devices-market (Accessed March 10, 2023).
2. Ti based biomaterials, the ultimate choice for orthopaedic implants - a review10.1016/j.pmatsci.2008.06.004 ↗
3. Tribocorrosion of porous titanium used in biomedical applications10.1007/s40735-018-0194-4 ↗
4. Lattice structures and functionally graded materials applications in additive manufacturing of orthopedic implants: a review
5. Aseptic loosening, not only a question of wear: a review of different theories10.1080/17453670610045902 ↗
6. A review of metastable beta titanium alloys10.3390/met8070506 ↗
7. Frontiers of 3D printing/additive manufacturing: from human organs to aircraft fabrication10.1016/j.jmst.2016.08.011 ↗
8. Metallic microlattice materials: a current state of the art on manufacturing, mechanical properties and applications10.1016/j.matdes.2016.01.146 ↗
9. Metallic powder-bed based 3D printing of cellular scaffolds for orthopaedic implants: a state-of-the-art review on manufacturing, topological design, mechanical properties and biocompatibility10.1016/j.msec.2017.02.094 ↗
10. Additive manufacturing of metallic lattice structures: unconstrained design, accurate fabrication, fascinated performances, and challenges10.1016/j.mser.2021.100648 ↗
11. Architected cellular materials: a review on their mechanical properties towards fatigue-tolerant design and fabrication10.1016/j.mser.2021.100606 ↗
12. Properties of Ti-6Al-4V non-stochastic lattice structures fabricated via electron beam melting10.1016/j.msea.2008.04.002 ↗
13. Fracture behavior under compression loading of surface-cleaned metallic lattice structures10.1007/s00170-022-09504-6 ↗
14. High-strength porous biomaterials for bone replacement: a strategy to assess the interplay between cell morphology, mechanical properties, bone ingrowth and manufacturing constraints10.1016/j.actbio.2015.10.048 ↗
15. Fatigue properties of Ti6Al4V cellular specimens fabricated via SLM: CAD vs real geometry10.1016/j.prostr.2017.11.068 ↗
16. Fabrication, pore structure and compressive behavior of anisotropic porous titanium for human trabecular bone implant applications10.1016/j.jmbbm.2015.02.023 ↗
17. Biomechanical stability of novel mechanically adapted open-porous titanium scaffolds in metatarsal bone defects of sheep10.1016/j.biomaterials.2014.12.010 ↗
18. Corrosion resistance improvement of additive manufactured scaffolds by anodizing10.1016/j.electacta.2020.137423 ↗
19. Corrosion, tribology, and tribocorrosion research in biomedical implants: progressive trend in the published literature10.1007/s40735-016-0060-1 ↗
20. In-vitro corrosion and wear of titanium alloys in the biological environment10.1016/0142-9612(96)00029-4 ↗
21. The corrosion behaviour of Ti—6Al—4V, Ti—6Al—7Nb and Ti—13Nb—13Zr in protein solutions10.1016/S0142-9612(98)00217-8 ↗
22. Tribocorrosion properties of different type titanium alloys in simulated body fluid10.1016/j.wear.2014.12.017 ↗
23. Tribocorrosion behavior of beta titanium biomedical alloys in phosphate buffer saline solution10.1016/j.jmbbm.2015.02.016 ↗
24. Synergism between mechanical wear and corrosion on tribocorrosion of a titanium alloy in a Ringer solution10.1016/j.jmrt.2018.11.004 ↗
25. Influence of fluoride content and pH on corrosion and tribocorrosion behaviour of Ti13Nb13Zr alloy in oral environment10.1016/j.jmbbm.2015.05.008 ↗
26. Corrosion behaviour of porous Ti intended for biomedical applications10.1007/s10934-016-0185-0 ↗
27. Structural characterization and electrochemical behavior of a laser-sintered porous Ti-10Mo alloy10.1016/j.corsci.2012.10.036 ↗
28. Study on the tribological properties of porous titanium sliding against tungsten carbide YG6
29. Tribocorrosion behavior of bio-functionalized highly porous titanium10.1016/j.jmbbm.2017.01.006 ↗
30. Influence of unit cell and geometry size on scaffolds electrochemical response10.1016/j.jelechem.2019.113528 ↗
31. Functionalization of Ti6Al4V scaffolds produced by direct metal laser for biomedical applications10.1016/j.matdes.2015.05.078 ↗
32. Mechanical evaluation of porous titanium (Ti6Al4V) structures with electron beam melting (EBM)10.1016/j.jmbbm.2009.10.006 ↗
33. Compression deformation behavior of Ti-6Al-4V alloy with cellular structures fabricated by electron beam melting10.1016/j.jmbbm.2012.10.005 ↗
34. Highly porous titanium scaffolds for orthopaedic applications10.1002/jbm.b.31682 ↗
35. ISO/ASTM, 2015. INTERNATIONAL STANDARD ISO / ASTM 52900 Additive manufacturing — General principles — Terminology, Int. Organ. Stand. 5, pp. 1–26. https://doi.org/10.1520/ISOASTM52900-15.10.1520/ISOASTM52900-15 ↗
36. Arcam, Ti6Al4V Titanium Alloy Ti6Al4V Titanium Alloy, (n.d.) 4–6.
37. F3335 standard guide for assessing the removal of additive manufacturing residues in medical devices fabricated by powder bed
38. E384: standard test method for knoop and vickers hardness of materials
39. Tribocorrosion behavior of Ti6Al4V alloy after thermo-chemical treatment and DLC deposition for biomedical applications10.1016/j.triboint.2020.106560 ↗
40. Additive manufacturing of metallic components by selective electron beam melting - a review10.1080/09506608.2016.1176289 ↗
41. A highly accurate methodology for the prediction and correlation of mechanical properties based on the slimness ratio of additively manufactured tensile test specimens10.1007/s10853-020-04654-y ↗
42. Additive manufacturing of titanium alloys by electron beam melting: a review10.1002/adem.201700842 ↗
43. Microstructures and mechanical properties of electron beam-rapid manufactured Ti-6Al-4V biomedical prototypes compared to wrought Ti-6Al-4V10.1016/j.matchar.2008.07.006 ↗
44. Revealing martensitic transformation and α / β interface evolution in electron beam melting Ti-6Al-4V
45. Surface modification of Ti6Al4V open porous structures produced by additive manufacturing10.1002/adem.201100344 ↗
46. The effect of spatial micro-CT image resolution and surface complexity on the morphological 3D analysis of open porous structures10.1016/j.matchar.2013.11.004 ↗
47. Selective laser melting of biocompatible metals for rapid manufacturing of medical parts10.1108/13552540710776142 ↗
48. Corrosion of Ti6Al4V pins produced by direct metal laser sintering10.1016/j.apsusc.2016.10.031 ↗
49. In situ impedance spectroscopy study of the electrochemical corrosion of Ti and Ti-6Al-4V in simulated body fluid at 25 ??C and 37 ??C10.1016/j.corsci.2009.06.035 ↗
50. Influence of structural transformations over the electrochemical behavior of Ti anodic films grown in 0.1 M NaOH10.1007/s10008-009-0838-x ↗
51. Pourbaix · 1996
52. Special modes of corrosion under physiological and simulated physiological conditions
53. Frequency dispersion in capacity measurements at a disk electrode10.1149/1.2407464 ↗
54. Impedance of passive oxide films with graded thickness: influence of the electrode and cell geometry10.1016/j.electacta.2009.07.004 ↗
55. The apparent constant-phase-element behavior of a disk electrode with faradaic reactions10.1149/1.2398894 ↗
56. Correlation of the nanostructure of the anodic layers fabricated on Ti13Nb13Zr with the electrochemical impedance response10.1016/j.corsci.2015.01.041 ↗
57. Electrochemical response of TiO2 anodic layers fabricated on Ti6Al4V alloy with nanoporous, dual and nanotubular morphology10.1016/j.corsci.2016.07.021 ↗
58. Preliminary investigation on the tribocorrosion behaviour of nanotubular structured Ti6Al4V surfaces10.1016/j.matlet.2017.11.067 ↗
59. Fretting corrosion behaviour of Ti-6Al-4V alloy in artificial saliva containing varying concentrations of fluoride ions10.1016/j.wear.2010.09.008 ↗
60. Influence of surface roughness on corrosion and tribological behavior of CP-Ti after thermal oxidation treatment10.1007/s11665-009-9504-9 ↗
61. Tribocorrosion behavior of additive manufactured Ti-6Al-4V biomedical alloy10.1016/j.triboint.2017.11.032 ↗
62. Corrosion assessment of Ti-6Al-4V fabricated using laser powder-bed fusion additive manufacturing10.1016/j.electacta.2018.04.189 ↗
63. Surface morphology in engineering applications: influence of roughness on sliding and wear in dry fretting10.1016/j.triboint.2011.04.020 ↗
64. Influence of fretting regimes on the tribocorrosion behaviour of Ti6Al4V in 0.9wt% sodium chloride solution10.1016/j.wear.2003.11.003 ↗
65. Tribological behaviour of Ti-based alloys in simulated body fluid solution at fretting contacts10.1016/j.msea.2004.02.027 ↗
66. The effects on bone cells of metal ions released from orthopaedic implants. a review
67. The role of mechanically activated area on tribocorrosion of CoCrMo10.1007/s11661-013-1759-y ↗
68. Comparison of wear properties of Ti6Al4V fabricated by wrought and electron beam melting processes in simulated body fluids10.1108/RPJ-09-2018-0256 ↗
69. Tribocorrosion response of the Ti6Al4V alloys commonly used in femoral stems10.1016/j.triboint.2013.09.022 ↗
70. Fretting corrosion behaviour of thermally oxidized CP-Ti in Ringer’s solution10.1016/j.corsci.2009.10.029 ↗