Pulse Heating Method for Investigation of Electroless Ni‐P Alloy Film Resistors
Source abstract
Abstract
The thermal stability of electroless Ni‐P alloy thin film resistors for pulse heating was investigated using the step stress test method. The resistance of electroless Ni‐P resistors is decreased by pulse heating. It was confirmed by a micro x‐ray diffraction analysis of the resistors after the step stress test that this resistance decrease is due to crystallization of the resistor films. The degree of crystallization can be quantitatively evaluated as the temperature coefficient of resistance of Ni‐P films calculated from resistance changes during pulse heating. The step stress test is demonstrated to be an effective and quick method of determining the thermal stability of thin film resistors for pulse heating, and it also gives an evaluation of the temperature coefficient of resistance of thin film resistors.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Electrical and Thermal Properties of Materials · Advanced Thermoelectric Materials and Devices · Semiconductor materials and interfaces
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Applied Chemistry, Waseda University, Okubo, Shinjuku‐ku, Tokyo 169, Japan
Nihon Parkerizing Company, Limited, Central Research Laboratories, Ohgami, Hiratsuka‐shi, Kanagawa 254, Japan
Oki Electric Industry Company, Limited, Research Laboratories, Higashi asakawa‐cho, Hachioji‐shi, Tokyo 193, Japan
References