Electron Reemission Mossbauer Study of Tinplate
Source abstract
Abstract
Electron reemission Mossbauer (ERM) studies using the Sn 119 Mossbauer isotope have been made on a series of tinplate samples with tin coatings ranging from 0.1 to 1.0 lb/bb (2.24 to 22.4 g/m 2 ). With a recently developed theory of ERM spectroscopy, the ERM spectra could be analyzed to determine the thickness of the oxide , metallic Sn, and alloy layers on the tinplate samples. The resulting thicknesses were found to be in good agreement with the nominal coating weights and, for several samples, with the metal and alloy thicknesses determined by standard stripping techniques. The ERM method is shown to be very sensitive to thin tin oxide layers ranging from a few monolayers to several hundred angstroms thick.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Electron and X-Ray Spectroscopy Techniques · Metallurgical Processes and Thermodynamics · Copper Interconnects and Reliability
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
U. S. Steel Corporation, Research Laboratory, Monroeville, Pennsylvania 15146
References
Reference metadata was not supplied for this record.