journal article·1995-06-01

Coulometry of a Mass‐Transfer Limited Reaction with a Membrane‐Covered Rotating Disk Electrode

Peter S. Fedkiw, Shihua Song, Sanjay Sharma, Jian‐Hui Ye

Publisher page

Abstract

The transient, convective‐diffusion equation for a single reactant consumed at a mass‐transfer‐limited rate on a rotating disk electrode (RDE) and a membrane‐covered RDE is solved via a perturbation method in the Laplace domain for predicting the coulombs discharged following a potential step from open‐circuit conditions. A formula is derived in each case for relating the rotation rate ω to the excess transient coulombs passed during the time required to establish a steady‐state current where . For an uncoated RDE, a plot of is predicted to be linear through the origin with a slope proportional to the reactant diffusivity to the one‐third power. For the membrane‐covered RDE, a similar plot is predicted in the high‐rotation rate limit to be a straight line with a nonzero intercept. The slope and intercept can be used with the formula provided for determining the diffusivity and partition coefficient of the reactant in the membrane. Experimental results are presented which validate the theoretical development.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Electrochemical Analysis and Applications · Molecular Junctions and Nanostructures · Fuel Cells and Related Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Chemical Engineering, North Carolina State University, Raleigh, North Carolina 27695‐7905

References

Reference metadata was not supplied for this record.