Filament Temperatures from Geometry-Independent Electron Emission Functions
Source abstract
Abstract
By expressing the surface area of an electrically heated body in terms of its current‐voltage characteristics and substituting in the Richardson equation, electron emission functions having the linear form are derived which fix the temperature of the body independent of its crosssectional area or dimensions. The functions can be directly determined experimentally; α and β are logarithmic functions of resistivity, emissivity, and the electron emission constants. In the simplest case a simultaneous measurement of electron emission and heating current is sufficient to fix the temperature. The method has particular application to vapor deposited filaments, and experimental determination of the emission functions has been made for "asdeposited" zirconium and thorium. For the former a spread in temperature prediction at 1600°K of ±5° was obtained from filaments 2–18 cm in length and 0.03–0.17 cm in diameter; for similar thorium filaments the spread was ±30°. Resistivities, emissivities, and electron emission constants were measured for both metals from 1300° to 1800°K and found to be consistent with literature data and the derived functions.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Electron and X-Ray Spectroscopy Techniques · Atomic and Molecular Physics · Scientific Measurement and Uncertainty Evaluation
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References