journal article·2018-03

Reduced bacterial adhesion on ceramics used for arthroplasty applications

Rita Sorrentino, Andrea Cochis, Barbara Azzimonti, Carlos Caravaca, Jerome Chevalier, Meinhard Kuntz, Alessandro Alan Porporati, Robert Michael Streicher, Lia Rimondini

Publisher page

Abstract

Orthopaedic-implant-related infections are challenging for clinicians: despite progresses in surgical procedures, the mortality rate of patients experiencing periprosthetic joint infections still ranges from 10 to 18%. Generally, infection starts when planktonic bacteria arising from surgery escape immunological surveillance adhering onto implant surface. Bacterial adhesion depends mainly on material’s intrinsic surface features depending on its chemical and physical properties. This study compares materials used for bearings of total hip arthroplasty, advanced ceramics (alumina and zirconia-platelet toughened alumina composites), metals (cobalt–chromium–molybdenum alloy) and polymers (highly cross-linked polyethylene), in terms of wettability and protein adsorption. Materials were infected with Staphylococcus aureus and Staphylococcus epidermidis biofilm for 24 or 48 h. Bacterial adhesion properties were evaluated by means of biofilm viability, morphology, and thickness, in a worst-case surface roughness condition. Thanks to selective protein adsorption, bioceramics reduced bacterial adhesion and subsequent biofilm formation more effectively in comparison with metal and polymer surfaces.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Orthopedic Infections and Treatments · Dental materials and restorations

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (44)

Show source-provided references
1. Prosthesis infections after orthopedic joint replacement: the possible role of bacterial biofilms
2. The biofilm formation onto implants and prosthetic materials may be contrasted using gallium (3+)10.4028/www.scientific.net/KEM.587.315 ↗
3. The epidemiology of revision total hip arthroplasty in the United States10.2106/JBJS.H.00155 ↗
4. The epidemiology of revision total knee arthroplasty in the United States10.1007/s11999-009-0945-0 ↗
5. Failures of total hip replacement: a population-based perspective
6. Treatment of periprosthetic joint infection using antimicrobials: dilute povidone-iodine lavage
7. Prevalence of total hip and knee replacement in the United States
8. Hip and knee replacement in Germany and the USA: analysis of individual inpatient data from German and US hospitals for the years 2005–2011
9. Utilization rates of hip arthroplasty in OECD countries
10. Epidemiology and burden of osteoarthritis10.1093/bmb/lds038 ↗
11. Mechanisms of antimicrobial resistance in ESKAPE pathogens
12. The effect of silver or gallium doped titanium against the multidrug resistant Acinetobacter baumannii10.1016/j.biomaterials.2015.11.042 ↗
13. The EPS matrix: the house of biofilm cells10.1128/JB.00858-07 ↗
14. Biofilm formation on titanium implants counteracted by grafting gallium and silver ions10.1002/jbm.a.35270 ↗
15. Effect of biofilms on recalcitrance of Staphylococcal joint infection to antibiotic treatment10.1093/infdis/jiu514 ↗
16. Infection of orthopedic implants with emphasis on bacterial adhesion process and techniques used in studying bacterial-material interactions10.4161/biom.22905 ↗
17. Causes of failure of ceramic-on-ceramic and metal-on-metal hip arthroplasties10.1007/s11999-011-2161-y ↗
18. Is a ceramic-on-ceramic bearing really superior to ceramic-on-polyethylene for primary total hip arthroplasty? A systematic review and meta-analysis of randomised controlled trials10.5301/hipint.5000223 ↗
19. Ceramic-on-ceramic versus ceramic-on-polyethylene bearing surfaces in total hip arthroplasty10.3928/01477447-20150402-63 ↗
20. How do wettability, zeta potential and hydroxylation degree affect the biological response of biomaterials?10.1016/j.msec.2016.12.107 ↗
21. Contact line structure and dynamics on surfaces with contact angle hysteresis10.1021/la970528q ↗
22. Effect of surface roughness and materials composition on biofilm formation10.4236/jbnb.2012.324056 ↗
23. Bioactive glass functionalized with alkaline phosphatase stimulates bone extracellular matrix deposition and calcification in vitro10.1016/j.apsusc.2014.06.001 ↗
24. Effect of hydrocarbon adsorption on the wettability of rare earth oxide ceramics10.1063/1.4886410 ↗
25. Comparison of surface roughness of oral hard materials to the threshold surface roughness for bacterial plaque retention: a review of the literature10.1016/S0109-5641(97)80038-3 ↗
26. Surface roughness and gloss of dental materials as a function of force and polishing time in vitro10.1016/j.dental.2005.04.013 ↗
27. Effect of surface roughness of biomaterials on Staphylococcus epidermidis adhesion10.1186/s12866-014-0234-2 ↗
28. The effect of surface roughness on early in vivo plaque colonization on titanium10.1902/jop.1997.68.6.556 ↗
29. Development and antimicrobial susceptibility studies of in vitro monomicrobial and polymicrobial biofilm models with Aspergillus fumigatus and Pseudomonas aeruginosa10.1186/1471-2180-14-53 ↗
30. Adhesion force of staphylococcus aureus on various biomaterial surfaces10.1016/j.jmbbm.2016.10.009 ↗
31. The impact of material surface roughness and temperature on the adhesion of Legionella pneumophila to contact surfaces10.1080/09603123.2014.963035 ↗
32. Comparative analysis of long-term biofilm formation on metal and ceramic brackets10.2319/102210-616.1 ↗
33. Surface properties of resin-based composite materials and biofilm formation: a review of the current literature
34. The influence of surface modification on bacterial adhesion to titanium-based substrates10.1021/am507148n ↗
35. In vitro biocompatibility and bacterial adhesion of physico-chemically modified Ti6Al4V surface by means of UV irradiation10.1016/j.actbio.2008.07.028 ↗
36. Do alumina matrix composite bearings decrease hip noises and bearing fractures at a minimum of 5 years after THA?10.1007/s11999-015-4428-1 ↗
37. Ceramic femoral components in total knee arthroplasty – two year follow-up results of an international prospective multi-centre study10.2174/1874325001206010172 ↗
38. Bacterial colonization of ceramic surfaces: an in vitro and in vivo study
39. Corrosion damage and wear mechanisms in long-term retrieved CoCr femoral components for total knee arthroplasty10.1016/j.arth.2016.05.006 ↗
40. The influence of Co-Cr and UHMWPE particles on infection persistence: an in vivo study in mice10.1002/jor.21526 ↗
41. Polyethylene and metal wear particles: characteristics and biological effects10.1007/s00281-011-0242-3 ↗
42. Implant failure and the incompetent fibro-inflammatory zone10.1097/00003086-199401000-00016 ↗
43. CORR insights1: the otto aufranc award: modifiable versus nonmodifiable risk factors for infection after hip arthroplasty10.1007/s11999-014-3866-5 ↗
44. The microbiologic profile associated with peri-implantitis in humans: a systematic review10.11607/jomi.4150 ↗