journal article·2000-04

Bioverit® I base glass/Ti particulate biocomposite: “in situ” vacuum plasma spray deposition

E Verné, M Ferraris, C Jana, L Paracchini

Publisher page

Abstract

Abstract Bioverit®I is a bioactive glass–ceramic used for bone substitutions in several fields of human surgery. In this work, the possibility of using Bioverit®I as matrix of a biocomposite toughened by Ti particles, in order to toughen this glass–ceramic and to widen its application fields, was investigated. Bioverit®I base glass matrix/Ti particle biocomposite (B1T) coatings were prepared by vacuum plasma spray (VPS), by spraying a mixture of glass powders and 15 vol% titanium particles on Ti–6Al–4V substrates. The composite coatings were prepared starting from the base glass powders, in order to fully utilise the softening properties of this material in its amorphous state. The coatings were characterised by optical and scanning electron microscopy (SEM), energy dispersion spectroscopy (EDS) and X-ray diffraction (XRD). Vickers indentations at the interface between the substrate and the coatings and shear strength measurements were performed in order to analyse the adherence of the coatings to the substrate. The surface reactivity of the coatings was evaluated by soaking the coated samples in a simulated body fluid (SBF) having the same ion concentration as the human plasma and by analysing the Si, Ca and P ion concentration while soaking.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Advanced materials and composites · Orthopaedic implants and arthroplasty

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (22)

Show source-provided references
1. Bioactive materials10.1016/0272-8842(95)00126-3 ↗
3. Bioceramics, a clinical success
4. Production and characterization of thin films of Bioverit®-type glasses deposited by RF magnetron-sputtering
5. Bioactive coatings of glass–ceramics on metals
6. Vacuum plasma spray deposition of titanium particle/glass–ceramic matrix biocomposites10.1111/j.1151-2916.1996.tb08759.x ↗
7. Verné, E. and Ferraris, M., Characterisation of vacuum plasma sprayed biocomposites. In Bioceramics, ed. A. Ravaglioli, 1995, Vol. 8, p. 147.
8. Bioactive glass–matrix composite coatings on titanium alloy
9. Ferraris, M., Rabajoli, P., Verné, E., Paracchini, L., Chiesa, R. and Brossa, F., Plasma sprayed biocomposites for clinical applications. In Materials in Clinical Applications — Advances Science and Technology, ed. P. Vincenzini. Techna S.r.l., Faenza, 1995, Vol. 12, p. 281.
10. Verné, E., Terzuolo, A., Mousty, F., Pigozzi, G., Ravaglioli, A., Krajewsky, A. and Piancastelli, A., Glass–matrix biocomposite coatings on a Ti–6Al–4V Alloy. In Bioceramics Coatings for Guided Bone Growth, ed. A. Ravaglioli and A. Krajewski. Gruppo Editoriale Faenza Editrice S.p.A, 1997, pp. 37–42.
11. Sintering and plasma spray deposition of bioactive glass–matrix composites for biomedical applications10.1016/S0955-2219(97)00134-9 ↗
12. Machineable and phosphate glass–ceramics,
13. Klinische Indikationen fur die Anwendung der Jenaer Bioaktiven Maschinell Bearbeitbaren Glaskeramik in der Orthopedie und Traumatologie
14. Maschinell Bearbeitbare Glaskeramik für die Kopf-Hals-Chirurgie
15. Ducheyne, P., In vivo and in vitro modeling of the biocompatibility of titanium. In Proceedings of the Six World Conference on Titanium, 1988, pp. 55–56.
17. Chemical reaction of bioactive glass and glass–ceramics with a simulated body fluid10.1007/BF00705272 ↗
18. Influence of residual stresses on the mechanical properties of a layered ceramic composite10.1016/0955-2219(96)00005-2 ↗
19. Loehman, R. E. and Tomsia, A. P., In Ceramic Joining — A Short Course, 98th Annual Meeting and Exposition of The American Ceramic Society, Indianapolis, USA, April 13–14, 1996.
20. Gruner, H., Dense oxide coatings, Technical Report, Plasma Technik, Switzerland, 1986.
21. Verné, E., Angelini, E., Rosalbino, F., Bona, E., and Paracchini, L., Structural, mechanical and electrochemical characterisation of vacuum plasma spray biocomposites. In Materials in Clinical Applications — Advances Science and Technology ed. P. Vincenzini. Techna S.r.l., Faenza 1999, Vol. 28, p. 223–230.
22. Verné, E., Ferraris, M., Vogel, J., Carl, G. and Jana, C., Bioverit I®/Ti biocomposite. In Proceedings of the ECCM — 8, European Conference on Composite materials, ed. Crivelli Visconti, Napoli, 1998, Vol. 1, p. 359.