journal article·2002-12

Correlation between microstructure and properties of biocomposite coatings

E Verné, E Bona, E Angelini, F Rosalbino, P Appendino

Publisher page

Abstract

Abstract A SiO 2 –CaO–Na 2 O (SCN) based bioactive glass was used to prepare glass–matrix/Ti particle composite coatings (SCNT). The coatings were obtained by vacuum plasma spray (VPS) on Ti–6Al–4V substrates. Two different deposition methods have been compared: (a) VPS of powders obtained by ball milling of sintered composites; (b) in situ plasma spray of mixed titanium and glass powders. For comparative purposes, pure SCN glass coatings were produced. The coating morphology and microstructure were observed by optical and scanning electron microscopy, compositional analyses by energy dispersive X-ray spectroscopy (EDS), and X-ray diffraction (XRD). Comparative mechanical tests were carried out by shear tests and by Vickers indentations at the interface between the substrate and the coatings. The bioactivity of glass- and composite coatings was investigated in vitro by soaking them in a simulated body fluid (SBF) with the same ion concentration of the human plasma. All the layers retain their starting composition. The composite coatings obtained by VPS of the powdered presintered composites showed a better mechanical behaviour with respect both to the composite coatings obtained by the in situ method and to the pure glass coatings. Both the glass- and the two kind of composite coatings revealed to be bioactive by the growth of a thick apatite layer after 30 days of soaking in SBF. The electrochemical behaviour of the SCNT coatings was evaluated by means of potentiodynamic anodic polarization curves and free corrosion potential measurements in Ringer solution at 25 °C. For comparative purposes the same analyses were performed on analogous bioactive glass-matrix/Ti particle composite coated samples, based on the system TiO 2 –SiO 2 –CaO–B 2 O 3 (TSCB), and obtained both by the in situ and by presintering method as well. The results of the electrochemical tests showed a better corrosion behaviour of the samples coated by VPS of powdered sintered composites with respect to those coated by in situ VPS composites.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Titanium Alloys Microstructure and Properties · Dental materials and restorations

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (21)

Show source-provided references
1. Wilson, J., Yli-Urpo, A. and Risto-Pekka, H., Bioactive glasses: clinical applications. In An Introduction to Bioceramics, Advances Series in Ceramics, Vol.1 ed. L.L. Hench and J. Wilson., World Scientific Publishing Co., 1993, p. 63.10.1142/9789814317351_0004 ↗
2. Bioactivity of CaO–SiO2 glasses added with various ions10.1007/BF00705275 ↗
3. Pressureless sintering of bioverit®III/Ti particle biocomposites10.1016/S0955-2219(99)00036-9 ↗
4. Vacuum plasma spray deposition of titanium particle/glass-ceramic matrix biocomposites10.1111/j.1151-2916.1996.tb08759.x ↗
5. Verné, E., Ferraris, M., Ventrella, A., Krajewski, A. and Ravaglioli, A., Bioactive glass–matrix composite coatings on titanium alloy. In Ceramic in Oral Surgery. ed. A. Ravagliol and A. Krajewsk., Gruppo Editoriale Faenza Editrice S.p.A., Faenza, 1995.
6. Ferraris M., Rabajoli P., Verné E., Paracchini L., Chiesa R. and Brossa F. Plasma sprayed biocomposites for clinical applications In: Materials in Clinical Applications- Advances Science and Technology, Vol.12, ed. P. Vincenzini, Techna Srl., 1995, p. 281.
7. Verné, E., Terzuolo, A., Mousty, F., Pigozzi, G., Ravaglioli, A., Krajewsky, A. and Piancastelli, A., Glass–matrix biocomposite coatings on a Ti–6Al–4V alloy. In Bioceramics Coatings for Guided Bone Growth, ed. Ravaglioli, A., Krajewski, A., Gruppo Editoriale Faenza Editrice S.p.A, Faenza, 1997.
8. Sintering and plasma spray deposition of bioactive glass-matrix composites for medical applications10.1016/S0955-2219(97)00134-9 ↗
9. Gruner · 1986
10. Bioactivity of Na2O–CaO–SiO2 Glasses10.1111/j.1151-2916.1995.tb08677.x ↗
11. Viscous phase sintering of particle-reinforced glass matrix composites10.1016/0955-2219(95)00114-X ↗
12. Glass-ceramic joining and coating of SiC/SiC for fusion applications10.1016/S0022-3115(98)00176-7 ↗
13. Joining of surface modified carbon/carbon composites using a barium-aluminum-boro-silicate glass10.1016/S0955-2219(97)00203-3 ↗
14. Interfacial Structure and strength of silicon-silicon diffusion bond10.1179/mst.1995.11.10.1035 ↗
15. Verné, E., Ferraris, M., Moisescu, C., Ravaglioli, A. and Krajewski, A., Mechanical characterisation of bioactive coatings on zirconia. In Bioceramics, Vol. 10, ed. L. sedel and C. Ray. Paris, France 1997, p. 199.10.1016/B978-008042692-1/50047-9 ↗
16. Liquid phase bonding of aluminium and aluminium/nicalon composite using copper interlayers10.1179/mst.1993.9.5.417 ↗
17. Chemical Reaction of Bioactive Glass and Glass-ceramics with a Simulated Body Fluid10.1007/BF00705272 ↗
18. Properties of functionally gradient composite consisting of hydroxyapatite containing glass coated titanium and characters for bioactive implant10.2109/jcersj.100.362 ↗
19. Influence of residual stresses on the mechanical properties of a layered ceramic composite10.1016/0955-2219(96)00005-2 ↗
20. Biocorrosion behavior of hydroxyapatite/bioactive glass plasma sprayed on Ti6Al4V10.1016/0254-0584(95)80035-2 ↗
21. Effect of hydroxyapatite thickness on metal ion release from Ti6Al4V substrates10.1016/0142-9612(96)89655-4 ↗