The oxidation resistance and electrical conductivity of various commercial ferritic stainless steels including STS444 were tested in an air atmosphere at 700℃. Crofer22 developed specially for SOFC interconnect was also examined for the aim of comparing with the test results of STS444. Although STS444 exhibited higher oxidation resistance than Corfer22, the electrical conductivity of the scale formed on Crofer22 was higher, indicating that the resistivity of scale formed on Crofer22 is much lower than that of STS444. To gain a better understanding of the relation between oxidation behavior and electrical conductivity, the oxide scales formed on STS444 and Crofer22 were analyzed in terms of the structure, composition, and phase. Consequently, the influence of alloying elements on electrical conductivity of Fe-Cr alloys was discussed.