Consideration of Spindle Immersion Depth on Determining the Viscosity of Glass Melts by Rotating Cylinder Method
Source abstract
Abstract
The influence of spindle immersion depth on the determination of glass melt viscosity was examined in rotating cylinder method. The exact adjustment of spindle immersion depth into soda lime silicate standard glass melts could be performed by self-constructed electric system. The results showed a slight dependence of viscosity value on the immersion depth change of spindle shaft. The viscosity error per unit length of spindle was 0.4%/mm under the present cylinder dimension.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Engineering Applied Research · Surface Roughness and Optical Measurements
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.