journal article·2008-01

Mechanical biocompatibilities of titanium alloys for biomedical applications

Mitsuo Niinomi

Publisher page

Abstract

Young's modulus as well as tensile strength, ductility, fatigue life, fretting fatigue life, wear properties, functionalities, etc., should be adjusted to levels that are suitable for structural biomaterials used in implants that replace hard tissue. These factors may be collectively referred to as mechanical biocompatibilities. In this paper, the following are described with regard to biomedical applications of titanium alloys: the Young's modulus, wear properties, notch fatigue strength, fatigue behaviour on relation to ageing treatment, improvement of fatigue strength, fatigue crack propagation resistance and ductility by the deformation-induced martensitic transformation of the unstable beta phase, and multifunctional deformation behaviours of titanium alloys.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Titanium Alloys Microstructure and Properties · Orthopaedic implants and arthroplasty · Bone Tissue Engineering Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (41)

Show source-provided references
1. Effects of thermochemical treatment on properties of cast Ti–6Al–7Nb alloy for dental applications10.2320/jinstmet1952.64.10_895 ↗
2. Fatigue, fretting fatigue and corrosion characteristics of biocompatible beta type titanium alloy conducted with various thermo-mechanical treatments10.2320/matertrans.45.1540 ↗
3. Notch fatigue properties of a Ti–29Nb–13Ta–4.6Zr alloy for biomedical applications10.2464/jilm.55.575 ↗
4. Effect of ageing treatment on mechanical properties of Ti–29Nb–13Ta–4.6Zr alloy for biomedical applications10.2320/jinstmet.70.295 ↗
5. Dynamic fracture toughness of Ti–6Al–4V alloy with various stabilities of β phase10.1007/BF02668531 ↗
6. Baba, Y., et al., 2005. Fabrication of porous titanium for biomedical applications/ultra high molecular polyethylene composites. In: Abstracts of the 137th Fall Meeting of Japan Institute of Metals, p. 441
7. Mechanical properties of a Ti–Nb–Al shape memory alloy10.2320/matertrans.45.1077 ↗
8. Effect of β phase stability at room temperature on mechanical properties of β-rich α+β type Ti–4.5Al–3V–2Mo–2Fe alloy10.2355/isijinternational.42.191 ↗
9. Fatigue characteristics of low cost β titanium alloys for healthcare and medical applications10.2320/matertrans.46.1570 ↗
10. Metallic biomaterials in body fluid and their surface modification
11. Fatigue and microstructural properties of quenched Ti–6Al–4V10.1007/BF02651620 ↗
12. Development of high toughness in austempered type ductile cast iron and evaluation of its properties
13. Design and Mechanical properties of new beta type titanium alloys for implant materials10.1016/S0921-5093(97)00808-3 ↗
14. Fretting fatigue strength of a Ti–6Al–4V alloy in a pseudo-body-fluid and quantitative analysis of the substances in the fluid
15. Matsumoto, H., et al., 2006. Strengthening of low Young’s modulus beta Ti–Nb–Sn alloys by thermomechanical processing. In: Proc. Materials & Processes for Medical Devices Conference, ASM International, pp. 9–14
16. Nakai, M., et al., 2006. Development of simple fabrication process of porous titanium and PMMA composite. In: Abstracts of the 28th Annual Meeting of Japanese Society for Biomaterials, p. 350
17. Mechanical properties of biomedical titanium alloys10.1016/S0921-5093(97)00806-X ↗
18. Niinomi, M., et al., 1999. Corrosion wear fracture of new β type biomedical titanium alloys, Mater. Sci. Eng. A, A263 193–19910.1016/S0921-5093(98)01167-8 ↗
19. Recent metallic materials for biomedical applications
20. Niinomi, M., 2003. Recent research and development in titanium alloys for biomedical applications and healthcare goods. In: STAM, vol. 4, pp. 445–45410.1016/j.stam.2003.09.002 ↗
21. Japanese research and development in metallic biomedical, dental and healthcare materials10.1007/s11837-005-0076-3 ↗
22. Mechanical characteristics and microstructure of drawn wire of Ti–29Nb–13Ta–4.6Zr for biomedical applications10.1016/j.msec.2006.04.008 ↗
23. Fatigue characteristics of metallic biomaterials10.1016/j.ijfatigue.2006.09.021 ↗
24. Recent research and development in metallic materials for biomedical, dental and healthcare products10.4028/www.scientific.net/MSF.539-543.193 ↗
25. Frictional wear characteristics of biomedical Ti–29Nb–13Ta–4.6Zr alloy with various microstructures in air and simulated body fluid10.1088/1748-6041/2/3/S15 ↗
26. The effect of deformation-induced transformation on the fracture toughness of commercial titanium alloys10.1007/BF02672590 ↗
27. Fatigue crack propagation in Ti–6Al–4V alloys
28. Mechanical properties and fracture characteristics of Ti–6Al–4V and Ti–5Al–2.5Fe with refined microstructure using hydrogen10.1007/BF02670611 ↗
29. Development of low rigidity β-type titanium alloy for biomedical applications10.2320/matertrans.43.2970 ↗
30. Wear characteristics of surface oxidation treated new biomedical β-type titanium alloy in simulated body environment10.2355/tetsutohagane1955.88.9_567 ↗
31. Fretting fatigue characteristics of new biomedical β-type titanium alloy in air and simulated body environment10.2355/tetsutohagane1955.88.9_553 ↗
32. Material characteristics and biocompatibility of low rigidity titanium alloys for biomedical applications
33. Titanium and its alloys
34. Niinomi, M., et al., 2006b. Improvement in wear resistance of beta-type titanium alloy for biomedical applications by surface coating of hard layer. In: Proc. 15th Int. Symp. on Processing and Fabrication of Advanced Materials, MT & T, pp. 141–161
35. Super elastic functional β titanium alloy with low Young’s modulus for biomedical applications
36. Niinomi, M., et al., 2007. In-situ X-ray analysis of mechanism of nonlinear super elastic behavior of Ti–Nb–Ta–Zr system beta-type titanium alloy for biomedical applications. Mater. Sci. Eng. C (in press)10.1016/j.msec.2007.04.028 ↗
37. Mechanical properties of porous titanium compacts prepared by powder sintering10.1016/j.scriptamat.2003.08.018 ↗
38. Deformation behaviors of Ti–Nb–Ta–Zr system alloys for biomedical applications10.2320/matertrans.45.1113 ↗
39. Sumita, M., et al., 1993. Study on improvement of fretting fatigue characteristics of high strength structural materials. In: Research Reports of National Institute for Materials Science, vol. 14, pp. 207–218
40. Contact pressure and fretting fatigue characteristics of highly workable titanium alloy with equiaxed α and Widmnstätten α structure10.2464/jilm.55.661 ↗
41. Tane, M., et al. (in preparation). Single-crystal elastic constants of β-type Ti–29Nb–13Ta–4.6Zr alloy developed for biomedical applications, Acta Mat