Mechanical evaluation of porous titanium (Ti6Al4V) structures with electron beam melting (EBM)
Source abstract
Abstract
Patient specific porous implants for the reconstruction of craniofacial defects have gained importance due to their better performance over their generic counterparts. The recent introduction of electron beam melting (EBM) for the processing of titanium has led to a one step fabrication of porous custom titanium implants with controlled porosity to meet the requirements of the anatomy and functions at the region of implantation. This paper discusses an image based micro-structural analysis and the mechanical characterization of porous Ti6Al4V structures fabricated using the EBM rapid manufacturing process. SEM studies have indicated the complete melting of the powder material with no evidence of poor inter-layer bonding. Micro-CT scan analysis of the samples indicate well formed titanium struts and fully interconnected pores with porosities varying from 49.75%-70.32%. Compression tests of the samples showed effective stiffness values ranging from 0.57(+/-0.05)-2.92(+/-0.17)GPa and compressive strength values of 7.28(+/-0.93)-163.02(+/-11.98)MPa. For nearly the same porosity values of 49.75% and 50.75%, with a variation in only the strut thickness in the sample sets, the compressive stiffness and strength decreased significantly from 2.92 GPa to 0.57 GPa (80.5% reduction) and 163.02 MPa to 7.28 MPa (93.54 % reduction) respectively. The grain density of the fabricated Ti6Al4V structures was found to be 4.423 g/cm(3) equivalent to that of dense Ti6Al4V parts fabricated using conventional methods. In conclusion, from a mechanical strength viewpoint, we have found that the porous structures produced by the electron beam melting process present a promising rapid manufacturing process for the direct fabrication of customized titanium implants for enabling personalized medicine.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Bone Tissue Engineering Materials · Cellular and Composite Structures · Additive Manufacturing and 3D Printing Technologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (38)
Show source-provided references
1. Techniques used to determine porosity
2. Ashby · 1988
3. Ashman, R.B., 1982. Ultrasonic determination of the elastic properties of cortical bone: Techniques and limitations. Ph.D. Dissertation, Tulane University, New Orleans
4. Brånemark · 1977
5. Variations in cortical material properties throughout the human dentate mandible10.1002/ajpa.10121 ↗
6. Direct fabrication of custom orthopedic implants using electron beam melting technology
7. Direct metal fabrication of titanium implants with tailored materials and mechanical properties using electron beam melting technology
8. Evaluation of titanium implant components directly fabricated through electron beam melting technology
9. Cellular Ti-6Al4V structures with interconnected macroporosity for bone implants fabricated by selective electron beam melting10.1016/j.actbio.2008.03.013 ↗
10. Cellular titanium by selective electron beam melting10.1002/adem.200700025 ↗
11. Corrosion of metal orthopedic implants10.2106/00004623-199802000-00015 ↗
12. Clinical applications of bone graft substitutes
13. Effect of select lens TM processing parameters on the deposition of Ti-6AI-4V10.1016/S1526-6125(05)70080-3 ↗
14. Laoui, T., Santos, E., Osakada, K., Shiomi, M., Morita, M., Shaik, S.K., Tolochko, N.K., Abe, F., 2004. Properties of titanium implants made by laser processing. Laser net shape engineering. In: M. Geiger, A. Otto (Eds.), Proceedings of LANE, pp. 475-484
15. The radiographic and imaging characteristics of porous tantalum implants within the human cervical spine10.1097/00007632-199806010-00014 ↗
16. Experimental and clinical performance of porous tantalum on orthopedic surgery10.1016/j.biomaterials.2006.04.041 ↗
17. Mechanical properties of cast Ti-6Al-4V lattice block structures10.1007/s11661-007-9440-y ↗
18. Cancellous bone from porous titanium by multiple coating technique
19. Preparation and characterization of porous titanium
20. Comparison of porous titanium made by sponge replication and directly 3D fiber deposition and cancellous bone10.4028/www.scientific.net/KEM.330-332.999 ↗
21. Porous titanium scaffolds directly fabricated by 3D fibre deposition technique: Effect of nozzle diameter
22. Structural and mechanical evaluations of a topology optimized titanium interbody fusion cage fabricated by selective laser melting process10.1002/jbm.a.31231 ↗
23. Fabrication and compressive response of open-cell aluminum foams with sub-millimeter pores
24. Mechanical properties of trabecular bone in the human mandible: Implications for dental implant treatment planning, and surgical placement10.1016/S0278-2391(99)90437-8 ↗
25. Park · 1992 · vol. 394
26. Parthasarathy, J., Starly, B., Raman, S., 2008. Design of patient-specific porous titanium implants for craniofacial applications. In: RAPID 2008 May 20–22. Lake Buena Vista, FL, USA: Society of Manufacturing Engineers
27. Computer aided bio-modeling and analysis of patient specific porous titanium mandibular implants10.1115/1.3192104 ↗
28. Material properties of the human cranial vault and zygoma
29. Material properties of the parietal bone10.1002/ar.10131 ↗
30. Elastic and ultimate properties of compact bone tissue10.1016/0021-9290(75)90075-5 ↗
31. Preliminary observations of bone ingrowth into porous materials10.1002/jbm.820100304 ↗
32. Porous titanium scaffolds fabricated using a rapid prototyping and powder metallurgy technique10.1016/j.biomaterials.2008.05.032 ↗
33. The effect of cell face curvature and corrugations on the stiffness and strength of metallic foams10.1016/S1359-6454(98)00072-X ↗
34. Starly, B., Gomez, C., Darling, A., Fang, Z., Lau, A., Sun, W., Lau, W., Bradbury, T., Youssef, A., Gaylo, C., 2003. Computer-aided bone scaffold design: A biomimetic approach. In: Proceedings of the IEEE 29th Annual Northeast Bioengineering Conference, pp. 172–17310.1109/NEBC.2003.1216047 ↗
35. Bio-CAD modeling and its application in computer-aided tissue engineering10.1016/j.cad.2005.02.002 ↗
36. Selective laser sintering of aluminium- and titanium-based composites: Processing and characterization10.1002/pssa.200309014 ↗
37. Wang, D., Wang, C., Zhang, X., Xu, L., 2005. Design and biomechanical evaluation of a custom lateral mandible titanium prosthesis. In: IEEE-EMBS 27th Annual International Conference, Engineering in Medicine and Biology Society, pp. 6188–619110.1109/IEMBS.2005.1615908 ↗
38. Comparison of magnetic resonance and computed tomographic image quality after the implantation of tantalum and titanium spinal instrumentation10.1097/00007632-199808010-00014 ↗