journal article·2017-08

Potential biodegradable Zn-Cu binary alloys developed for cardiovascular implant applications

Zibo Tang, Jialin Niu, Hua Huang, Hua Zhang, Jia Pei, Jingmin Ou, Guangyin Yuan

Publisher page

Abstract

Binary Zn-Cu alloy system is developed as potential biodegradable materials for cardiovascular implant application. The microstructure, tensile properties, in vitro corrosion behavior, cytotoxicity and antibacterial property of as-extruded Zn-xCu (x=1, 2, 3, and 4wt%) alloys are investigated systematically. It shows that as Cu content increases more CuZn5 phase precipitates. After extrusion, the CuZn5 phases are broken and the grains of Zn-xCu alloys are refined. Tensile test shows that Cu addition could significantly improve the mechanical properties of Zn-xCu alloys. Particularly, the elongation of the Zn-4Cu reaches 50.6±2.8%, which could facilitate the micro-tubes processing for stent fabrication. The micro-tubes of 3mm in outer diameter and 0.2mm in thickness as well as vascular stents have been fabricated successfully using the Zn-Cu binary alloy. The degradation rates of Zn-xCu alloys in c-SBF solution are quite low, which vary from 22.1±4.7 to 33.0±1.0μmyear-1. With increasing Cu concentration, the corrosion rates of the Zn-xCu alloys generally exhibit a little increase compared with pure Zn, which show no significant difference among Zn-xCu alloys. In vitro test shows that Zn-xCu alloys exhibit acceptable cytotoxicity to human endothelial cells and the antibacterial property (S. aureus) is perfect when Cu concentration is higher than 2wt%. Therefore, the newly developed Zn-xCu binary alloys could be promising candidates for biodegradable cardiovascular implant application due to their excellent combination of strength and ductility, low degradation rates, acceptable cytotoxicity and good antibacterial property.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Magnesium Alloys: Properties and Applications · Aluminum Alloys Composites Properties · Corrosion Behavior and Inhibition

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (44)

Show source-provided references
1. American Society for Testing and Materials, 2004a. ASTM-E8-04: standard test methods for tension testing of metallic materials. American Society for Testing and Materials. In: Annual book of ASTM standards. Philadelphia, PA: American Society for Testing and Materials.
2. American Society for Testing and Materials, 2004b. ASTM-G31-72: Standard Practice for Laboratory Immersion Corrosion Testing of Metals. In: Annual book of ASTM standards. Philadelphia, PA: American Society for Testing and Materials .
3. Anon, 1980. Copper. In: Recommended Dietary Allowances. National Research Council, Food Nutrition Board, NRC/NAS, Washington, D.C.
4. Zinc exhibits ideal physiological corrosion behavior for bioabsorbable stents10.1002/adma.201300226 ↗
5. Metallic implant biomaterials10.1016/j.mser.2014.10.001 ↗
6. Antibacterial activity of chitosan tripolyphosphate nanoparticles loaded with various metal ions10.1016/j.carbpol.2008.07.039 ↗
7. Revealing extraordinary intrinsic tensile plasticity in gradient nano-grained copper10.1126/science.1200177 ↗
8. Copper and angiogenesis: unravelling a relationship key to cancer progression10.1111/j.1440-1681.2008.04969.x ↗
9. The stimulation of angiogenesis and collagen deposition by copper10.1016/j.biomaterials.2009.10.009 ↗
10. In vitro biodegradation behavior, mechanical properties, and cytotoxicity of biodegradable Zn-Mg alloy10.1002/jbm.b.33341 ↗
11. Metallic copper as an antimicrobial surface10.1128/AEM.02766-10 ↗
12. The deformation and ageing of mild steel: iii discussion of results10.1088/0370-1301/64/9/303 ↗
13. Influence of trace impurities on the in vitro and in vivo degradation of biodegradable Mg-5Zn-0.3Ca alloys10.1016/j.actbio.2015.05.004 ↗
14. International Organization for Standardization, 1999. International Organization for Standardization. ISO B 10993-5: Biological evaluation of medical devices–Part 5: Tests for in Vitro Cytotoxicity.
15. International Organization for Standardization, 2004c. Textile Fabrics: Determination of Antibacterial Activity: Agar Difusion Plate Test.
16. Kattner · 1990 · 148
17. Superplasticity in a new dispersion strengthened zinc alloy10.1007/BF02645595 ↗
18. Development of biodegradable Zn-1X binary alloys with nutrient alloying elements Mg, Ca and Sr10.1038/srep10719 ↗
19. Biodegradable Mg-Cu alloys with enhanced osteogenesis, angiogenesis, and long-lasting antibacterial effects10.1038/srep27374 ↗
20. In vitro investigation of ultra-pure Zn and its mini-tube as potential bioabsorbable stent material10.1016/j.matlet.2015.06.107 ↗
21. In Vivo and In Vitro Studies of Biodegradable WE43 Stent10.4028/www.scientific.net/AMM.528.70 ↗
22. Liver copper storage and transport during development: implications for cytotoxicity10.1093/ajcn/63.5.812 ↗
23. Unidirectional solidification of Zn-rich Zn–Cu peritectic alloys—I. Microstructure selection10.1016/S1359-6454(99)00365-1 ↗
24. Direct determination of plasma copper and zinc in infants by atomic absorption with discrete nebulization10.1093/clinchem/27.8.1445 ↗
25. Tables of standard electrode potentials10.1149/1.2131790 ↗
26. Novel Zn-based alloys for biodegradable stent applications: design, development and in vitro degradation10.1016/j.jmbbm.2016.03.018 ↗
27. Cytotoxicity evaluation of biodegradable Zn-3Mg alloy toward normal human osteoblast cells10.1016/j.msec.2015.01.056 ↗
28. Research on a Zn-Cu alloy as a biodegradable material for potential vascular stents application10.1016/j.msec.2016.06.082 ↗
29. Preparation and assessment of revised simulated body fluids10.1002/jbm.a.10482 ↗
30. Preliminary results after application of absorbable metal stents in patients with critical limb ischemia10.1583/04-1349R.1 ↗
31. Long-term biocompatibility of a corrodible peripheral iron stent in the porcine descending aorta10.1016/j.biomaterials.2006.05.029 ↗
32. Study of copper precipitation behavior in a Cu-bearing austenitic antibacterial stainless steel10.1016/j.matdes.2010.11.030 ↗
33. Particle effects on recrystallization in magnesium–manganese alloys: particle-stimulated nucleation10.1016/j.actamat.2009.02.032 ↗
34. In vitro cytotoxicity, adhesion, and proliferation of human vascular cells exposed to zinc10.1021/acsbiomaterials.6b00035 ↗
35. Evaluation of antibacterial activity of ZnO nanoparticles coated sonochemically onto textile fabrics
36. Trace elements in human physiology and pathology: zinc and metallothioneins10.1016/S0753-3322(03)00081-7 ↗
37. Mechanical and corrosion properties of newly developed biodegradable Zn-based alloys for bone fixation10.1016/j.actbio.2011.05.008 ↗
38. Mechanical and corrosion properties of newly developed biodegradable Zn-based alloys for bone fixation10.1016/j.actbio.2011.05.008 ↗
39. Recommendation for modifying current cytotoxicity testing standards for biodegradable magnesium-based materials10.1016/j.actbio.2015.04.011 ↗
40. Processing aspects of magnesium alloy stent tube
41. Research on an Mg-Zn alloy as a degradable biomaterial10.1016/j.actbio.2009.06.028 ↗
42. Effects of extrusion and heat treatment on the mechanical properties and biocorrosion behaviors of a Mg–Nd–Zn–Zr alloy10.1016/j.jmbbm.2011.05.026 ↗
43. Microstructure, mechanical properties, biocorrosion behavior, and cytotoxicity of as-extruded Mg-Nd-Zn-Zr alloy with different extrusion ratios10.1016/j.jmbbm.2012.02.002 ↗
44. Biodegradable metals10.1016/j.mser.2014.01.001 ↗