The effect of post-sintering treatments on the fatigue and biological behavior of Ti-6Al-4V ELI parts made by selective laser melting
Source abstract
Abstract
Fatigue resistance and biocompatibility are key parameters for the successful implantation of hard-tissue prostheses, which nowadays are more and more frequently manufactured by selective laser melting (SLM). For this purpose, the present paper is aimed at investigating the effect of post-sintering treatments on the fatigue behavior and biological properties of Ti samples produced by SLM. After the building process, all samples are heat treated to achieve a complete stress relief. The remaining ones are tribofinished with the aim of reducing the surface roughness of the as-sintered condition. Part of the tribofinished samples are then subjected to one of the following post-sintering treatments: (i) shot peening, (ii) hot isostatic pressing (HIP), and (iii) electropolishing. It is found that shot peening and HIP are the most effective treatments to improve the high and the very-high cycle fatigue resistance, respectively. At the same time, they preserve the good biocompatibility ensured by the biomedical Titanium Grade 23.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Additive Manufacturing Materials and Processes · Additive Manufacturing and 3D Printing Technologies · Titanium Alloys Microstructure and Properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (64)
Show source-provided references
1. Additive manufacturing of dense metal parts by electron beam melting
2. Post-processing of selective laser sintered metal parts10.1108/13552549510086853 ↗
3. Osteoblast adhesion on biomaterials10.1016/S0142-9612(99)00242-2 ↗
4. Corrosion behaviour of commercially pure titanium shot blasted with different materials and sizes of shot particles for dental implant applications10.1016/S0142-9612(02)00314-9 ↗
5. Subsurface crack initiation in high cycle fatigue in Ti6A14V and in a typical martensitic stainless steel10.1016/0036-9748(83)90385-X ↗
6. The effect of different surface morphology and roughness on osteoblast-like cells10.1002/jbm.a.31652 ↗
7. Fatigue behavior of Ti6Al4V and 316 LVM blasted with ceramic particles of interest for medical devices10.1016/j.jmbbm.2013.10.013 ↗
8. Wire based additive layer manufacturing: comparison of microstructure and mechanical properties of Ti–6Al–4V components fabricated by laser-beam deposition and shaped metal deposition10.1016/j.jmatprotec.2011.01.018 ↗
9. The effect of bi-modal and lamellar microstructures of Ti-6Al-4V on the behaviour of fatigue cracks emanating from edge-notches10.1111/j.1460-2695.2004.00825.x ↗
10. Influence of sharp microstructural gradients on the fatigue crack growth resistance of α + β and near-α titanium alloys10.1111/j.1460-2695.2005.00932.x ↗
11. High- and very high-cycle plain fatigue resistance of shot peened high-strength aluminum alloys: the role of surface morphology10.1016/j.ijfatigue.2014.07.002 ↗
12. On the combination of the critical distance theory with a multiaxial fatigue criterion for predicting the fatigue strength of notched and plain shot-peened parts10.1016/j.ijfatigue.2016.08.015 ↗
13. Additive manufactured Ti-6Al-4V using welding wire: comparison of laser and arc beam deposition and evaluation with respect to aerospace material specifications10.1016/j.phpro.2010.08.087 ↗
14. Brandl, E., Leyens, C., Palm, F., 2011. Mechanical properties of additive manufactured Ti-6Al-4V using wire and powder based processes, in: IOP Conference Series: Materials Science and Engineering. IOP Publishing, p. 012004.10.1088/1757-899X/26/1/012004 ↗
15. Additive manufactured AlSi10Mg samples using Selective Laser Melting (SLM): microstructure, high cycle fatigue, and fracture behavior10.1016/j.matdes.2011.07.067 ↗
16. Mechanical properties of open-cell metallic biomaterials manufactured using additive manufacturing10.1016/j.matdes.2013.01.071 ↗
17. Fatigue characterization of titanium Ti-6Al-4V samples produced by additive manufacturing10.1016/j.prostr.2016.06.395 ↗
18. The removal torque of titanium screw inserted in rabbit tibia treated by dual acid etching10.1016/S0142-9612(03)00218-7 ↗
19. Progress toward an integration of process–structure–property–performance models for “three-dimensional (3-D) printing” of titanium alloys10.1007/s11837-014-1007-y ↗
20. Microstructure and mechanical properties of Ti-6Al-4V produced by electron beam melting of pre-alloyed powders10.1108/13552540910960262 ↗
21. Ductility of a Ti-6Al-4V alloy produced by selective laser melting of prealloyed powders10.1108/13552541011083371 ↗
22. Analytical modelling of residual stress in additive manufacturing10.1111/ffe.12560 ↗
23. Metal additive manufacturing: a review10.1007/s11665-014-0958-z ↗
24. Froes · 2014 · 19
25. On the nature and crystallographic orientation of subsurface cracks in high cycle fatigue of Ti-6Al-4V10.1007/BF02656635 ↗
26. Gong, H., Rafi, K., Starr, T., Stucker, B., 2012. Effect of defects on fatigue tests of as-built Ti-6Al-4V parts fabricated by selective laser melting, in: Proceedings of the Solid Freeform Fabrication Symposium, Austin, TX, USA. pp. 6–8.
27. In situ characterization of the deformation and failure behavior of non-stochastic porous structures processed by selective laser melting10.1016/j.msea.2011.07.026 ↗
28. Fatigue performance of additive manufactured TiAl6V4 using electron and laser beam melting
29. Computational prediction of the fatigue behavior of additively manufactured porous metallic biomaterials10.1016/j.ijfatigue.2015.11.017 ↗
30. Significance of nano-and microtopography for cell-surface interactions in orthopaedic implants
31. Improvement of fatigue resistance and ductility of TiAl6V4 processed by selective laser melting10.1016/j.jmatprotec.2015.01.025 ↗
32. Binding mechanisms in selective laser sintering and selective laser melting10.1108/13552540510573365 ↗
33. Titanium nanostructures for biomedical applications
34. Osteoblastic cell behaviour on different titanium implant surfaces10.1016/j.actbio.2007.12.002 ↗
35. Change in surface roughness by dynamic shape-memory acrylate networks enhances osteoblast differentiation10.1016/j.biomaterials.2016.08.004 ↗
36. On the mechanical behaviour of titanium alloy TiAl6V4 manufactured by selective laser melting: fatigue resistance and crack growth performance10.1016/j.ijfatigue.2012.11.011 ↗
37. The role and future of the laser technology in the additive manufacturing environment10.1016/j.phpro.2010.08.123 ↗
38. Predicting sintering deformation of ceramic film constrained by rigid substrate using anisotropic constitutive law10.1016/j.actamat.2010.07.015 ↗
39. Fatigue behavior of thin-walled grade 2 titanium samples processed by selective laser melting. Application to life prediction of porous titanium implants10.1016/j.jmbbm.2013.08.011 ↗
40. Lütjering · 2007
41. Microstructure and mechanical behavior of Ti–6Al–4V produced by rapid-layer manufacturing, for biomedical applications10.1016/j.jmbbm.2008.05.004 ↗
42. Characterization of titanium aluminide alloy components fabricated by additive manufacturing using electron beam melting10.1016/j.actamat.2009.11.032 ↗
43. Next-generation biomedical implants using additive manufacturing of complex, cellular and functional mesh arrays
44. Metal fabrication by additive manufacturing using laser and electron beam melting technologies10.1016/S1005-0302(12)60016-4 ↗
45. Park · 1992
46. Mechanical evaluation of porous titanium (Ti6Al4V) structures with electron beam melting (EBM)10.1016/j.jmbbm.2009.10.006 ↗
47. Pederson · 2002
48. Microstructure and tensile properties of selectively laser-melted and of HIPed laser-melted Ti–6Al–4V10.1016/j.msea.2013.04.099 ↗
49. A comparison of the tensile, fatigue, and fracture behavior of Ti–6Al–4V and 15-5 PH stainless steel parts made by selective laser melting10.1007/s00170-013-5106-7 ↗
50. Duality of the S–N fatigue curve caused by competing failure modes in a titanium alloy and the role of Poisson defect statistics10.1016/j.actamat.2004.12.032 ↗
51. Porous titanium scaffolds fabricated using a rapid prototyping and powder metallurgy technique10.1016/j.biomaterials.2008.05.032 ↗
52. The effects on bone cells of metal ions released from orthopaedic implants. A review
53. Microstructure and mechanical properties of pure titanium models fabricated by selective laser melting10.1243/0954406041319545 ↗
54. Heat treatment of Ti-6Al-7Nb components produced by selective laser melting10.1108/13552540810907974 ↗
55. Commercially pure titanium (cp-Ti) versus titanium alloy (Ti6Al4V) materials as bone anchored implants — Is one truly better than the other?10.1016/j.msec.2016.01.032 ↗
56. Fatigue performance of additive manufactured metallic parts10.1108/13552541311302932 ↗
57. Development of porous medical implant scaffolds via laser additive manufacturing10.1016/S1003-6326(12)61706-3 ↗
58. Electropolishing of CP titanium and its alloys in an alcoholic solution-based electrolyte10.4012/dmj.27.258 ↗
59. Van Hooreweder, B., Boonen, R., Moens, D., Kruth, J.-P., Sas, P., 2012. On the determination of fatigue properties of Ti6Al4V produced by selective laser melting, in: Structures, Structural Dynamics, and Materials and Co-Located Conferences 53rd Aiaa/Asme/Asce/Ahs/Asc. American Institute of Aeronautics and Astronautics.10.2514/6.2012-1733 ↗
60. As-fabricated and heat-treated microstructures of the Ti-6Al-4V alloy processed by selective laser melting10.1007/s11661-011-0731-y ↗
61. Microstructural and mechanical approaches of the selective laser melting process applied to a nickel-base superalloy10.1016/j.msea.2011.11.092 ↗
62. High Cycle Fatigue (HCF) performance of Ti-6Al-4V alloy processed by selective laser melting10.4028/www.scientific.net/AMR.816-817.134 ↗
63. Ti-6Al-4V additively manufactured by selective laser melting with superior mechanical properties10.1007/s11837-015-1297-8 ↗
64. Material properties of Ti6Al4V parts produced by laser metal deposition10.1016/j.phpro.2012.10.056 ↗