journal article·2014-11Open access

A robust anisotropic hyperelastic formulation for the modelling of soft tissue

D.R. Nolan, A.L. Gower, M. Destrade, R.W. Ogden, J.P. McGarry

Abstract

The Holzapfel-Gasser-Ogden (HGO) model for anisotropic hyperelastic behaviour of collagen fibre reinforced materials was initially developed to describe the elastic properties of arterial tissue, but is now used extensively for modelling a variety of soft biological tissues. Such materials can be regarded as incompressible, and when the incompressibility condition is adopted the strain energy Ψ of the HGO model is a function of one isotropic and two anisotropic deformation invariants. A compressible form (HGO-C model) is widely used in finite element simulations whereby the isotropic part of Ψ is decoupled into volumetric and isochoric parts and the anisotropic part of Ψ is expressed in terms of isochoric invariants. Here, by using three simple deformations (pure dilatation, pure shear and uniaxial stretch), we demonstrate that the compressible HGO-C formulation does not correctly model compressible anisotropic material behaviour, because the anisotropic component of the model is insensitive to volumetric deformation due to the use of isochoric anisotropic invariants. In order to correctly model compressible anisotropic behaviour we present a modified anisotropic (MA) model, whereby the full anisotropic invariants are used, so that a volumetric anisotropic contribution is represented. The MA model correctly predicts an anisotropic response to hydrostatic tensile loading, whereby a sphere deforms into an ellipsoid. It also computes the correct anisotropic stress state for pure shear and uniaxial deformations. To look at more practical applications, we developed a finite element user-defined material subroutine for the simulation of stent deployment in a slightly compressible artery. Significantly higher stress triaxiality and arterial compliance are computed when the full anisotropic invariants are used (MA model) instead of the isochoric form (HGO-C model).
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Elasticity and Material Modeling · Automotive and Human Injury Biomechanics · Mechanical Engineering and Vibrations Research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (29)

Show source-provided references
1. Abaqus/Standard users manual, Ver. 6.10, 2010. Dassault Systèmes Simulia Corporation, Pawtucket.
2. ADINA theory and modeling guide, 2005. ADINA R&D, Inc., Watertown.
3. Effect of tissue properties, shape and orientation of microcalcifications on vulnerable cap stability using different hyperelastic constitutive models10.1016/j.jbiomech.2014.01.010 ↗
4. A computational test-bed to assess coronary stent implantation mechanics using a population-specific approach10.1007/s13239-012-0104-8 ↗
5. Slight compressibility and sensitivity to changes in Poisson׳s ratio10.1002/nme.3326 ↗
7. FDA, 2010. Guidance for Industry and FDA Staf—Non-Clinical Engineering Tests and Recommended Labeling for Intravascular Stents and Associated Delivery Systems.
8. Volumetric-distortional decomposition of deformation and elasticity tensor10.1177/1081286509105591 ↗
9. A rate-independent elastoplastic constitutive model for biological fiber-reinforced composites at finite strains10.1007/s00466-002-0347-6 ↗
10. Chondrocyte deformation and local tissue strain in articular cartilage10.1002/jor.1100130315 ↗
11. On non-physical response in models for fiber-reinforced hyperelastic materials10.1016/j.ijsolstr.2010.04.005 ↗
12. A new constitutive framework for arterial wall mechanics and a comparative study of material models10.1023/A:1010835316564 ↗
13. Comparison of a multi-layer structural model for arterial walls with a Fung-type model, and issues of material stability10.1115/1.1695572 ↗
14. Modelling cell wall growth using a fibre-reinforced hyperelasticviscoplastic constitutive law10.1016/j.jmps.2011.12.003 ↗
15. The influence of vascular anatomy on carotid artery stenting: a parametric study for damage assessment10.1016/j.jbiomech.2014.01.008 ↗
16. Experimental studies and numerical analysis of the inflation and interaction of vascular balloon catheter-stent systems10.1007/s10439-008-9606-9 ↗
17. Finite element based nonlinear normalization of human lumbar intervertebral disc stiffness to account for its morphology
18. Computational examination of the effect of material inhomogeneity on the necking of stent struts under tensile loading10.1115/1.2722776 ↗
19. Deficiencies in numerical models of anisotropic nonlinearly elastic materials10.1007/s10237-012-0442-3 ↗
20. Computational modelling of diarthrodial joints. Physiological, pathological and pos-surgery simulations10.1007/s11831-006-9001-3 ↗
21. On the numerical simulation of the mechanical behaviour of articular cartilage10.1002/nme.1638 ↗
22. On the physical assumptions underlying the volumetric-isochoric split and the case of anisotropy10.1016/j.euromechsol.2007.04.001 ↗
23. Spatial variation in cartilage T2 of the knee10.1002/jmri.1150 ↗
24. Shear of rubber tube springs10.1016/j.ijnonlinmec.2007.07.002 ↗
25. Numerical approximation of tangent moduli for finite element implementations of nonlinear hyperelastic material models10.1115/1.2979872 ↗
26. High shear stress after successful balloon angioplasty is associated with restenosis and target lesion revascularization10.1067/mhj.2002.123110 ↗
27. On anisotropic elasticity and questions concerning its Finite Element implementation10.1007/s00466-013-0871-6 ↗
28. Finite element implementation of incompressible, transversely isotropic hyperelasticity10.1016/0045-7825(96)01035-3 ↗
29. Shear stress, vascular remodeling and neointimal formation10.1016/S0021-9290(02)00446-3 ↗