Fatigue of Nitinol: The state-of-the-art and ongoing challenges

M.J. Mahtabi, Nima Shamsaei, M.R. Mitchell

Publisher page

Abstract

Nitinol, a nearly equiatomic alloy of nickel and titanium, has been considered for a wide range of applications including medical and dental devices and implants as well as aerospace and automotive components and structures. The realistic loading condition in many of these applications is cyclic; therefore, fatigue is often the main failure mode for such components and structures. The fatigue behavior of Nitinol involves many more complexities compared with traditional metal alloys arising from its uniqueness in material properties such as superelasticity and shape memory effects. In this paper, a review of the present state-of-the-art on the fatigue behavior of superelastic Nitinol is presented. Various aspects of fatigue of Nitinol are discussed and microstructural effects are explained. Effects of material preparation and testing conditions are also reviewed. Finally, several conclusions are made and recommendations for future works are offered.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Shape Memory Alloy Transformations · Titanium Alloys Microstructure and Properties · Advanced Welding Techniques Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (100+)

Show source-provided references
1. Nitinol stent fractures in the SFA
2. ASTM E466-07 · 2007
3. ASTM E606/E606M-12 · 2012
4. ASTM E1049-85, 2011. Practices for Cycle Counting in Fatigue Analysis (No. E1049-85(2011)e1), E08. ASTM International.
5. ASTM E2207-08(2013)e1 · 2008
6. ASTM E2948-14 · 2014
7. Decrease in the fatigue resistance of nickel–titanium rotary instruments after clinical use in curved root canals10.1016/j.tripleo.2004.10.013 ↗
8. The exponential law of endurance tests
9. Thermomechanical cycling of a NiTi shape memory alloy-macroscopic response and microstructural evolution10.1016/j.ijplas.2014.01.006 ↗
10. Thermomechanical transformation fatigue of TiNiCu SMA actuators under a corrosive environment—Part I: Experimental results10.1016/j.ijfatigue.2009.04.012 ↗
11. Thermomechanical study of the stress assisted two way memory effect fatigue in TiNi and CuZnAl wires10.1016/S1359-6462(96)00228-X ↗
12. Carpenter, B., Lyons, J., 2001. EO-1 Technology Validation Report: Lightweight Flexible Solar Array Experiment. NASAGSFC (last update August 8).
13. Effect of electrical heating conditions on functional fatigue of thin NiTi wire for shape memory actuators10.1016/j.proeng.2011.04.564 ↗
14. In vivo MR angiographic quantification of axial and twisting deformations of the superficial femoral artery resulting from maximum hip and knee Flexion10.1097/01.RVI.0000220367.62137.E8 ↗
15. Coda, A., 2014. Progress on the correlation between inclusions and fatigue behavior in NiTi shape memory alloys for biomedical applications: refinement of the statistical approach. In: Presented at the International Conference on Shape Memory and Superelastic Technologies (SMST) (May 12–16, 2014), ASM.
16. The cyclic straining and fatigue of metals
17. Variable amplitude cyclic deformation and fatigue behaviour of stainless steel 304L including step, periodic, and random loadings10.1111/j.1460-2695.2009.01429.x ↗
18. Improvement of the fatigue resistance of NiTi endodontic files by surface and bulk modifications10.1111/j.1365-2591.2010.01759.x ↗
19. Transmission electron microscopy investigation of dislocation slip during superelastic cycling of Ni–Ti wires10.1016/j.ijplas.2010.05.005 ↗
20. Mean stress effects in strain-life fatigue10.1111/j.1460-2695.2009.01404.x ↗
21. An overview of Nitinol medical applications10.1016/S0921-5093(99)00294-4 ↗
22. Structural and functional fatigue of NiTi shape memory alloys10.1016/j.msea.2003.10.327 ↗
23. Shape memory materials for biomedical applications10.1002/1527-2648(200203)4:3<91::AID-ADEM91>3.0.CO;2-B ↗
24. Elahinia · 2015
25. Manufacturing and processing of NiTi implants: a review10.1016/j.pmatsci.2011.11.001 ↗
26. Multiaxial fatigue: an overview and some approximation models for life estimation10.1016/j.ijfatigue.2011.01.003 ↗
27. A critical plane approach to multiaxial fatigue damage including out-of-phase loading10.1111/j.1460-2695.1988.tb01169.x ↗
28. Microstructure and structural fatigue of ultra-fine grained NiTi-stents10.1016/j.msea.2008.02.059 ↗
29. Elementary deformation and damage mechanisms during fatigue of pseudoelastic NiTi microstents10.1002/adem.201180001 ↗
30. SmartFlex® NiTi wires for shape memory actuators10.1007/s11665-009-9407-9 ↗
31. Effect of rotational speed on nickel–titanium file distortion10.1016/S0099-2399(99)80124-1 ↗
32. Pseudoelastic cyclic stress–strain response of over-aged single crystal Ti–50.8at% Ni10.1016/S1359-6462(98)00399-6 ↗
33. The role of texture in tension–compression asymmetry in polycrystalline NiTi10.1016/S0749-6419(98)00060-6 ↗
34. Cyclic fatigue of nickel–titanium rotary instruments after clinical use with low-and high-torque endodontic motors10.1097/00004770-200112000-00015 ↗
35. Godard, O.J., Lagoudas, M.Z., Lagoudas, D.C., 2003. Design of space systems using shape memory alloys. In: Smart Structures and Materials. International Society for Optics and Photonics, pp. 545–558.10.1117/12.483469 ↗
36. Fracture mechanics and microstructure in NiTi shape memory alloys10.1016/j.actamat.2008.10.055 ↗
37. Haberland, C., Elahinia, M., Walker, J., Meier, H., Frenzel, J., 2013. Additive Manufacturing of Shape Memory Devices and Pseudoelastic Components.10.1115/SMASIS2013-3070 ↗
38. On the development of high quality NiTi shape memory and pseudoelastic parts by additive manufacturing10.1088/0964-1726/23/10/104002 ↗
39. Aerospace applications of shape memory alloys10.1243/09544100JAERO211 ↗
40. Transformation behaviour with thermal cycling in Ti50Ni43Cu7 shape memory alloy10.1016/j.msea.2006.04.081 ↗
41. Fatigue thresholds of Ni–Ti alloy near the shape memory transition temperature10.1016/S0142-1123(99)00065-1 ↗
42. Design and development of miniature mechanisms for small spacecraft
43. A modification of Morrow and Smith–Watson–Topper mean stress correction models10.1111/j.1460-2695.2011.01577.x ↗
44. Jensen · 2005
45. Whole-life transformation ratchetting and fatigue of super-elastic NiTi Alloy under uniaxial stress-controlled cyclic loading10.1016/j.msea.2011.12.071 ↗
46. Fatigue properties of the Ti–Ni base shape memory alloy wire10.2320/matertrans.43.1703 ↗
47. Kim, Y.S., Miyazaki, S., 1997. Fatigue properties of Ti–50.9at% Ni shape memory wires. In: Pelton, A.R., Hodgson Russell, S.M., Duerig, T. (Eds.), Proc. Second Int. Conf. Shape Mem. Superelastic Technol. SMST Pac. Grove MIAS SMST-97, pp. 473–477.
48. Influence of the structure on the strain-controlled fatigue of Nitinol10.4028/www.scientific.net/MSF.738-739.316 ↗
49. Kugler, C., Matson, D., Perry, K., 2000. Non-zero mean fatigue test protocol for NiTi. In: Russell, S.M., Pelton, A.R. (Eds.), SMST-2000: Proceedings of the International Conference on Shape Memory and Superelastic Technologies, Pacific Grove, CA, USA, p. 409.
50. Lagoudas, D.C., Li, C., Miller, D.A., Rong, L., 2000. Thermomechanical Transformation Fatigue of SMA Actuators, pp. 420–429.10.1115/IMECE2000-1682 ↗
51. Thermomechanical fatigue of shape memory alloys10.1088/0964-1726/18/8/085021 ↗
52. Influence of microstructural purity on the bending fatigue behavior of VAR-melted superelastic Nitinol10.1016/j.jmbbm.2014.02.008 ↗
53. Mechanical behavior of an Ni–Ti shape memory alloy under axial-torsional proportional and nonproportional loading10.1115/1.2816007 ↗
54. Mahtabi, M.J., Shamsaei, N., 2015. Multiaxial fatigue modeling for Nitinol shape memory alloys under in-phase loading. under review.10.1002/9781118426913.ch5 ↗
55. Fatigue of pseudoelastic NiTi within the stress-induced transformation regime: a modified Coffin–Manson approach10.1088/0964-1726/21/11/112001 ↗
56. Fatigue properties of a pseudoelastic NiTi alloy: Strain ratcheting and hysteresis under cyclic tensile loading10.1016/j.ijfatigue.2014.03.011 ↗
57. Thermal stress and low cycle fatigue10.1115/1.3625225 ↗
58. Effect of cyclic loading on apparent Young’s modulus and critical stress in nano-subgrained superelastic NiTi shape memory alloys10.2320/matertrans.47.735 ↗
59. Fatigue-crack growth behavior in the superelastic and shape-memory alloy Nitinol10.1007/s11661-001-1008-7 ↗
60. An experimental study of the superelastic effect in a shape-memory Nitinol alloy under biaxial loading10.1016/S0167-6636(02)00310-1 ↗
61. NiTi fatigue behavior10.1063/1.328738 ↗
62. Fatigue of NiTi thermoelastic martensites10.1016/0001-6160(79)90065-8 ↗
63. Fatigue of NiTi and CuZnAl shape memory alloys10.1016/B978-1-4832-8412-5.50206-X ↗
64. Design and application of shape memory actuators10.1140/epjst/e2008-00679-9 ↗
65. Review of the mechanical properties of cast steels with emphasis on fatigue behavior and the influence of microdiscontinuities10.1115/1.3443549 ↗
66. Mitchell · 1979
67. Mitchell, M.R., 1996. Fundamentals of Modern Fatigue Analysis for Design.10.31399/asm.hb.v19.a0002364 ↗
68. Thermal and stress cycling effects and fatigue properties of Ni–Ti alloys10.1016/B978-0-7506-1009-4.50037-8 ↗
69. Effect of thermal cycling on the transformation temperatures of Ti–Ni alloys10.1016/0001-6160(86)90263-4 ↗
70. Effect of cyclic deformation on the pseudoelasticity characteristics of Ti–Ni alloys10.1007/BF02644447 ↗
71. Fatigue life of Ti–50at% Ni and Ti–40Ni–10Cu (at%) shape memory alloy wires10.1016/S0921-5093(99)00344-5 ↗
72. Miyazaki, S., Sugaya, Y., Otsuka, K., 1988. Effects of various factors on fatigue life of Ti–Ni alloys. In: Proceedings of the MRS International Meeting on Advanced Materials. pp. 251–256.
73. A review of shape memory alloy research, applications and opportunities10.1016/j.matdes.2013.11.084 ↗
74. Morgan, N.B., Painter, J., Moffat, A., 2004. Mean strain effects and microstructural observations during in vitro fatigue testing of NiTi. In: SMST-2003. Proceedings of the International Conference on Shape Memory and Superelastic Technologies. SMST Society, Pacific Grove, CA, pp. 303–310.
75. Fatigue analysis of shape memory alloys: energy approach10.1088/0964-1726/14/5/017 ↗
76. Cyclic behavior and energy approach to the fatigue of shape memory alloys10.2140/jomms.2009.4.395 ↗
77. The effect of curvature angle and rotational speed on the cyclic fatigue of three types of rotary instrument (In vitro): comparative study
78. Unnotched fatigue behavior of an austenitic Ni–Ti shape memory alloy10.1016/j.msea.2008.07.025 ↗
79. Superelastic and cyclic response of NiTi SMA at various strain rates and temperatures10.1016/j.mechmat.2005.07.004 ↗
80. Fracture of self-expanding nitinol stents stressed in vitro under simulated intravascular conditions10.1016/j.jvs.2008.02.029 ↗
81. A comparison of zero mean strain rotating beam fatigue test methods for Nitinol wire10.1007/s11665-014-0939-2 ↗
82. A study of the effect of diameter on the fatigue properties of NiTi wire10.1007/s11665-009-9415-9 ↗
83. Evaluation of an energy-based approach and a critical plane approach for predicting constant amplitude multiaxial fatigue life10.1016/S0142-1123(99)00111-5 ↗
84. Patel, M.M., Gordon, R., 2006. An investigation of diverse surface finishes on fatigue properties of superelastic nitinol wire. In: International Conference on Shape Memory and Superelastic Technologies (SMST).
85. Characterizing fatigue response of nickel–titanium alloys by rotary beam testing10.1520/JAI100390 ↗
86. Nitinol fatigue: a review of microstructures and mechanisms10.1007/s11665-011-9864-9 ↗
87. Optimisation of processing and properties of medical grade Nitinol wire10.3109/13645700009063057 ↗
88. A guide to shape memory and superelasticity in Nitinol medical devices10.1080/13645700410017236 ↗
89. Rotary-bending fatigue characteristics of medical-grade Nitinol wire10.1016/j.jmbbm.2013.06.003 ↗
90. Pelton, A.R., Gong, X.-Y., Duerig, T., 2003. Fatigue testing of diamond-shaped specimens. In: Medical Device Materials-Proceedings of the Materials and Processes for Medical Devices Conference, pp. 199–204.
91. Fatigue and durability of Nitinol stents10.1016/j.jmbbm.2007.08.001 ↗
92. Peng, F., Jiang, X.-X., Hu, Y.-R., Ng, A., 2005. Application of shape memory alloy actuators in active shape control of inflatable space structures. In: Aerospace Conference, 2005 IEEE. IEEE, pp. 1–10.
93. A review of cyclic fatigue testing of nickel–titanium rotary instruments10.1016/j.joen.2009.06.015 ↗
94. Prahlad, H., Chopra, I., 2001. Design of a variable twist tilt-rotor blade using shape memory alloy (SMA) actuators. In: SPIE’s Eighth Annual International Symposium on Smart Structures and Materials. International Society for Optics and Photonics, pp. 46–59.10.1117/12.436559 ↗
95. Cyclic torsional loading of pseudoelastic NiTi shape memory alloys: damping and fatigue failure10.1016/j.msea.2005.10.037 ↗
96. Cyclic fatigue testing of nickel–titanium endodontic instruments10.1016/S0099-2399(97)80250-6 ↗
97. Residual stresses in LENS® components using neutron diffraction and contour method10.1016/j.msea.2005.02.019 ↗
98. Reinoehl, M., Bradley, D., Bouthot, R., Proft, J., 2000. The influence of melt practice on final fatigue properties of superelastic NiTi wires. In: Proceedings of the International Conference on Shape Memory and Superelastic Technologies, April, pp. 397–403.
99. Mechanical fatigue and fracture of Nitinol10.1179/1743280411Y.0000000009 ↗
100. In vitro fatigue–crack growth and fracture toughness behavior of thin-walled superelastic Nitinol tube for endovascular stents: a basis for defining the effect of crack-like defects10.1016/j.biomaterials.2006.09.034 ↗