Continuum damage model for bioresorbable magnesium alloy devices — Application to coronary stents
Source abstract
Abstract
The main drawback of a conventional stenting procedure is the high risk of restenosis. The idea of a stent that "disappears" after having fulfilled its mission is very intriguing and fascinating, since it can be expected that the stent mass decreases in time to allow the gradual transmission of the mechanical load to the surrounding tissues owing to controlled dissolution by corrosion. Magnesium and its alloys are appealing materials for designing biodegradable stents. The objective of this work is to develop, in a finite element framework, a model of magnesium degradation that is able to predict the corrosion rate, thus providing a valuable tool for the design of bioresorbable stents. Continuum damage mechanics is suitable for modeling several damage mechanisms, including different types of corrosion. In this study, the damage is assumed to be the superposition of stress corrosion and uniform microgalvanic corrosion processes. The former describes the stress-mediated localization of the corrosion attack through a stress-dependent evolution law, while the latter affects the free surface of the material exposed to an aggressive environment. Comparisons with experimental tests show that the developed model can reproduce the behavior of different magnesium alloys subjected to static corrosion tests. The study shows that parameter identification for a correct calibration of the model response on the results of uniform and stress corrosion experimental tests is reachable. Moreover, three-dimensional stenting procedures accounting for interaction with the arterial vessel are simulated, and it is shown how the proposed modeling approach gives the possibility of accounting for the combined effects of an aggressive environment and mechanical loading.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Magnesium Alloys: Properties and Applications · Corrosion Behavior and Inhibition · Hydrogen embrittlement and corrosion behaviors in metals
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (61)
Show source-provided references
1. Non-linear continuous damage, localization instability and convergence10.1115/1.3173674 ↗
2. h-adaptive finite element methods for dynamic problems, with emphasis on localization10.1002/nme.1620362409 ↗
3. Corrosion fatigue behavior of extruded magnesium alloy AZ61 under three different corrosive environments10.1016/j.ijfatigue.2008.02.012 ↗
4. Mechanical aspects of corrosion fatigue and stress corrosion cracking10.1016/S0020-7683(01)00002-6 ↗
5. Ams insight—adsorbable metal stent implantation for treatment of below-the-knee critical limb ischemia: 6-month analysis10.1007/s00270-008-9472-8 ↗
6. Assessment of tissue prolapse after balloon-expandable stenting: influence of stent cell geometry10.1016/j.medengphy.2008.11.002 ↗
7. Biodegradable stents: “fulfilling the mission and stepping away”10.1161/01.CIR.102.4.371 ↗
8. A simple model for slow strain rate and constant load corrosion tests of austenitic stainless steel in acid aqueous solution containing sodium chloride10.1016/j.corsci.2008.07.020 ↗
9. Realistic finite element-based stent design: the impact of balloon folding10.1016/j.jbiomech.2007.08.014 ↗
10. Fundamental issues in finite element analysis of localization of deformation10.1108/eb023897 ↗
11. Validated numerical modelling of galvanic corrosion for couples: magnesium alloy (AE44)-mild steel and AE44-aluminium alloy (AA6063) in brine solution10.1016/j.corsci.2010.06.031 ↗
12. Numerical modeling of micro-galvanic corrosion
13. Testing and mesoscale modelling of hydrogen assisted cracking of magnesium10.1016/j.engfracmech.2009.07.009 ↗
14. Drug-eluting bioresorbable magnesium stent10.1111/j.1540-8183.2004.04081.x ↗
15. Temporary scaffolding of coronary arteries with bioadsorbable magnesium stents: a perspective, non-randomised multicentre trial10.1016/S0140-6736(07)60853-8 ↗
16. The road to bioresorbable stents: reaching clinical reality ?10.1007/s00270-004-0341-9 ↗
17. A randomized comparison of coronary artery-stent placement and balloon angioplasty in the treatment of coronary artery disease10.1056/NEJM199408253310802 ↗
18. Quantitative evaluation of environmentally assisted cracking: a survey of developments and application of modelling concepts10.1115/1.2928722 ↗
19. On the effects of different strategies in modelling balloon-expandable stenting by means of finite element method10.1016/j.jbiomech.2008.01.027 ↗
20. In vitro corrosion and biocompatibility of binary magnesium alloys10.1016/j.biomaterials.2008.10.021 ↗
21. Damage and fracture simulation during the extrusion processes10.1016/S0045-7825(99)00109-7 ↗
22. Iron–manganese: new class of metallic degradable biomaterials prepared by powder metallurgy10.1179/174329008X284868 ↗
23. Developments in metallic biodegradable stents10.1016/j.actbio.2009.10.006 ↗
24. Fe–Mn alloys for metallic biodegradable stents: degradation and cell viability studies10.1016/j.actbio.2009.11.025 ↗
25. Biocorrosion of magnesium alloys: a new principle in cardiovascular implant technology ?10.1136/heart.89.6.651 ↗
26. Determination of layer-specific mechanical properties of human coronary arteries with nonatherosclerotic intimal thickening and related constitutive modeling10.1152/ajpheart.00934.2004 ↗
27. Effect of carbonate content and buffer type on calcium phosphate formation in sbf solutions10.1007/s10856-006-9680-1 ↗
28. On the finite element modelling of balloon-expandable stents10.1016/j.jmbbm.2007.07.002 ↗
29. Stress corrosion of rare-earth containing magnesium alloys ZE41, QE22 and Elektron 21 (EV31A) compared with AZ8010.1016/j.msea.2007.07.070 ↗
30. Design of a pseudo-physiological test bench specific to the development of biodegradable metallic biomaterials10.1016/j.actbio.2007.09.012 ↗
31. Corrosion of magnesium and its alloys10.1016/j.corsci.2009.04.025 ↗
32. Negative vascular remodelling after implantation of bioadsorbable magnesium alloy stents in porcine coronary arteries: a randomised comparison with bare-metal and sirolimus-eluting stents10.1136/hrt.2007.139261 ↗
33. Muller, H., 2009. Development of metallic bioabsorbable intravascular implants, In: N. Chakf, B. Durand (Eds.), ESVB 2009 New Technologies in Vascular Biomaterials, Connecting Biomaterials to Arterial Structures, Europrot, Strasbourg, France, pp. 23–32 (Chapter 3).
34. Corrosion fatigue behavior of extruded magnesium alloy AZ31 in sodium chloride solution10.1016/j.ijfatigue.2007.09.005 ↗
35. Bioabsorbable coronary stents10.1161/CIRCINTERVENTIONS.109.859173 ↗
36. Corrosion behaviour of magnesium/aluminium alloys in 3.5 wt% NaCl10.1016/j.corsci.2007.11.005 ↗
37. Preliminary results after application of adsorbable metal stents in patients with critical limb ischemia10.1583/04-1349R.1 ↗
38. Long-term biocompatibility of a corrodible peripheral iron stent in the porcine descending aorta10.1016/j.biomaterials.2006.05.029 ↗
39. A novel approach to temporary stenting: degradable cardiovascular stents produced from corrodible metal—results 6–18 months after implantation into New Zealand white rabbits10.1136/heart.86.5.563 ↗
40. Magnesium—an update on physiological, clinical and analytical aspects10.1016/S0009-8981(99)00258-2 ↗
41. Stable pitting corrosion of stainless steel as diffusion-controlled dissolution process with a sharp moving electrode boundary10.1016/j.corsci.2006.03.019 ↗
42. Bioabsorbable metal stents for percutaneous treatment of critical recoarctation of the aorta in a newborn
43. A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease10.1056/NEJM199408253310801 ↗
44. Control of biodegradation of biocompatable magnesium alloys10.1016/j.corsci.2007.01.001 ↗
45. Corrosion mechanisms of magnesium alloys10.1002/(SICI)1527-2648(199909)1:1<11::AID-ADEM11>3.0.CO;2-N ↗
46. Recent insights into the mechanism of magnesium corrosion and research suggestions10.1002/adem.200600221 ↗
47. Finite element simulation of metal forming and in-plane crack propagation using ductile continuum damage model10.1016/S0045-7949(02)00205-5 ↗
48. A pooled analysis of data comparing sirolimus-eluting stents with bare-metal stents10.1056/NEJMoa066633 ↗
49. Magnesium and its alloys as orthopedic biomaterials: a review10.1016/j.biomaterials.2005.10.003 ↗
50. Short-term effects of biocorrodible iron stents in porcine coronary arteries10.1111/j.1540-8183.2007.00319.x ↗
51. Study on the effect of corrosion on the tensile properties of the 1.0 wt% Yttrium modified AZ91 magnesium alloy10.1016/j.msea.2009.03.053 ↗
52. A finite-element computational model of chloride-induced transgranular stress-corrosion cracking of austenitic stainless steel10.1016/j.actamat.2008.04.068 ↗
53. Characterization of stress corrosion cracking (SCC) of Mg–Al alloys10.1016/j.msea.2007.11.064 ↗
54. Stress corrosion cracking in magnesium alloys: characterization and prevention10.1007/s11837-007-0104-6 ↗
55. A critical review of the stress corrosion cracking (SCC) of magnesium alloys10.1002/adem.200500071 ↗
56. The history of biodegradable magnesium implants: a review10.1016/j.actbio.2010.02.028 ↗
57. In vitro and vivo corrosion measurements of magnesium alloys10.1016/j.biomaterials.2005.07.037 ↗
58. Degradable biomaterials based on magnesium corrosion10.1016/j.cossms.2009.04.001 ↗
59. In vivo corrosion of four magnesium alloys and the associated bone response10.1016/j.biomaterials.2004.09.049 ↗
60. First successful implantation of a biodegradable metal stent into the left pulmunary artery of a preterm baby
61. Progress an challenge for magnesium alloys as biomaterials10.1002/adem.200800035 ↗