journal article·2014-01

The application of digital volume correlation (DVC) to study the microstructural behaviour of trabecular bone during compression

F. Gillard, R. Boardman, M. Mavrogordato, D. Hollis, I. Sinclair, F. Pierron, M. Browne

Publisher page

Abstract

Digital Volume Correlation (DVC) has been emerged recently as an innovative approach to full volume (i.e. internal) displacement and strain field measurement in materials and structures, particularly in conjunction with high resolution X-ray computed tomography (CT). As a relatively novel technique certain aspects of precision, accuracy and the breadth of application are yet to be fully established. This study has applied DVC to volume images of porcine trabecular bone assessing the effect of noise and sub-volume size on strain measurement. Strain resolutions ranging between 70 and 800με were obtained for the optimum sub-volume size of 64 voxels with a 50% overlap for metrological studies conducted. These values allowed the mechanical behaviour of porcine trabecular bone during compression to be investigated. During compression a crushed layer formed adjacent to the boundary plate which increased in thickness as the specimen was further deformed. The structure of the crushed layer was altered to such an extent that it confounded the correlation method. While investigating this factor, it was found that for reliable strain calculations a correlation coefficient of 0.90 or above was required between the sub-volumes in the reference and the deformed volumes. Good agreements between the results and published bone strain failures were obtained. Using the full field strain measurements, Poisson's ratio was identified for each compression step using a dedicated inverse method called the virtual fields method (VFM). It was found that for a given region outside of the crushed zone the Poisson ratio decreased from 0.32 to 0.21 between the first and the final compression steps, which was hypothesised to be due to the bone geometry and its resulting deformation behaviour. This study demonstrates that volumetric strain measurement can be obtained successfully using DVC, making it a useful tool for quantitatively investigating the micro-mechanical behaviour of macroscale bone specimens.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Elasticity and Material Modeling · Optical measurement and interference techniques · Medical Imaging Techniques and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (78)

Show source-provided references
1. Stress reconstruction and constitutive parameter identification in plane-stress elasto-plastic problems using surface measurements of deformation fields10.1007/s11340-007-9084-2 ↗
2. Identification of elasto-visco-plastic parameters and characterization of Luders behavior using digital image correlation and the virtual fields method10.1016/j.mechmat.2008.03.007 ↗
3. Methods and applications of digital volume correlation10.1243/03093247JSA436 ↗
4. Digital volume correlation: three-dimensional strain mapping using X-ray tomography10.1007/BF02323555 ↗
5. Measurement of strain distributions within vertebral body sections by texture correlation10.1097/00007632-199901010-00004 ↗
6. The mechanical adaptations of bones. By John Currey. Princeton, New Jersey: Princeton University Press. 198410.1002/ajpa.1330680117 ↗
7. Deformable image registration and 3D strain mapping for the quantitative assessment of cortical bone microdamage10.1016/j.jmbbm.2011.12.009 ↗
8. Strain gauges used in the mechanical testing of bones Part I: theoretical and technical aspects
9. Strain gauges used in the mechanical testing of bones Part II: “in vitro” and “in vivo” technique
10. Full-field strain mapping by optical correlation of micrographs acquired during deformation10.1111/j.1365-2818.2005.01461.x ↗
11. Dally · 1978
12. Mechanical and textural properties of pelvic trabecular bone10.1016/0021-9290(93)90014-6 ↗
13. The influence of acetabular cup material on pelvis cortex surface strains, measured using digital image correlation10.1016/j.jbiomech.2011.11.042 ↗
14. High-contrast resolution of ct images for bone-structure analysis10.1118/1.596847 ↗
15. Dym · 1973
16. 3-dimensional anatomy of the cancellous structures within the proximal femur from computed-tomography data10.1002/jor.1100130406 ↗
17. Full three-dimensional strain measurements on wood exposed to three-point bending: analysis by use of digital volume correlation applied to synchrotron radiation micro-computed tomography image data10.1111/j.1475-1305.2009.00687.x ↗
18. Assessment of corneal deformation using optical coherence tomography and digital volume correlation
19. Gates · 2011 · 164
20. 3D strain field measurement by correlation of volume images using scattered light: recording of images and choice of marks10.1111/j.1475-1305.2007.00340.x ↗
21. Full 3D measurement of strain field by scattered light for analysis of structures10.1007/s11340-006-9029-1 ↗
22. Biomechanics of cellular solids10.1016/j.jbiomech.2004.09.027 ↗
23. Applying the virtual fields method to the identification of elasto-plastic constitutive parameters10.1016/j.ijplas.2005.04.007 ↗
24. The virtual fields method for extracting constitutive parameters from full-field measurements: a review
25. Discrete and continuum analysis of localised deformation in sand using X-ray mu CT and volumetric digital image correlation10.1680/geot.2010.60.5.315 ↗
26. Improved three-dimensional image correlation for surface displacement measurement (vol 35, pp. 1911, 1996)
27. Effect of microstructure on the mechanical properties of Haversian cortical bone10.1016/j.bone.2005.09.017 ↗
28. Mesostructure of the localization in prestrained mild steel10.1016/S1359-6462(99)00425-X ↗
29. A homogenization sampling procedure for calculating trabecular bone effective stiffness and tissue-level stress10.1016/0021-9290(94)90019-1 ↗
30. Characterization of bones by speckle interferometry10.1080/0309190021000025864 ↗
31. Measurement of material elastic constants of trabecular bone: a micromechanical analytic study using a 1GHz acoustic microscope10.1016/S0736-0266(01)00061-4 ↗
32. Three-dimensional displacement measurements using digital image correlation and photogrammic analysis10.1007/BF02322695 ↗
33. Biomechanics of trabecular bone10.1146/annurev.bioeng.3.1.307 ↗
34. Differences between the tensile and compressive strengths of bovine tibial trabecular bone depend on modulus10.1016/0021-9290(94)90054-X ↗
35. Experimental and numerical characterisation of the elasto-plastic properties of bovine trabecular bone and a trabecular bone analogue10.1016/j.jmbbm.2011.11.013 ↗
36. Identification of the local stiffness reduction of a damaged composite plate using the virtual fields method10.1016/j.compositesa.2007.04.006 ↗
37. Thermographic strain analysis of the proximal canine femur10.1016/S1350-4533(96)00015-X ↗
38. Yield strain behavior of trabecular bone10.1016/S0021-9290(98)00057-8 ↗
39. Neutron strain measurement10.1179/1743284710Y.0000000029 ↗
40. Volumetric digital image correlation applied to X-ray microtomography images from triaxial compression tests on argillaceous rock10.1111/j.1475-1305.2007.00348.x ↗
41. Poroelastic properties of bovine vertebral trabecular bone10.1002/jor.1100180421 ↗
42. Analysis and artifact correction for volume correlation measurements using tomographic images from a laboratory X-ray source10.1007/s11340-010-9397-4 ↗
43. Accuracy and precision of digital volume correlation in quantifying displacements and strains in trabecular bone10.1016/j.jbiomech.2007.04.019 ↗
44. Micromechanical analyses of vertebral trabecular bone based on individual trabeculae segmentation of plates and rods10.1016/j.jbiomech.2008.10.035 ↗
45. Computation of full-field displacements in a scaffold implant using digital volume correlation and finite element analysis10.1016/j.medengphy.2013.02.001 ↗
46. Matheny · 2011
47. Moreno, V., Vázquez-Vázquez, C., Gallas, M., Crespo, J., 2011. Speckle Shearing Pattern Interferometry to Assess Mechanical Strain in the Human Mandible Jaw Bone Under Physiological Stress. 800131-800131.10.1117/12.892165 ↗
48. Full-field strain measurement and identification of composites moduli at high strain rate with the virtual fields method10.1007/s11340-010-9433-4 ↗
49. High-resolution finite element models with tissue strength asymmetry accurately predict failure of trabecular bone10.1016/S0021-9290(00)00149-4 ↗
50. Identification of Poisson's ratios of standard and auxetic low-density polymeric foams from full-field measurements10.1243/03093247JSA613 ↗
51. Extension of the virtual fields method to elasto-plastic material identification with cyclic loads and kinematic hardening10.1016/j.ijsolstr.2010.06.022 ↗
52. Pierron · 2012
53. Pierron, F., McDonald, S. A., Hollis, D., Fu, J., Withers, P. J. and Alderson, A. (2013), Comparison of the Mechanical Behaviour of Standard and Auxetic Foams by X-ray Computed Tomography and Digital Volume Correlation. Strain. 10.1111/str.1205310.1111/str.12053 ↗
54. Full-field strain mapping by optical correlation of micrographs acquired during deformation10.1111/j.1365-2818.2005.01461.x ↗
55. Multi-axial mechanical properties of human trabecular bone10.1007/s10237-008-0128-z ↗
56. Three-dimensional image correlation from X-ray computed tomography of solid foam10.1016/j.compositesa.2007.11.011 ↗
57. High-throughput quantification of the mechanical competence of murine femora — a highly automated approach for large-scale genetic studies10.1016/j.bone.2013.02.015 ↗
58. Tomographic PIV: principles and practice10.1088/0957-0233/24/1/012001 ↗
59. Digital volume correlation applied to compaction of granular materials10.1016/j.piutam.2012.05.020 ↗
60. Interpretation of experimental data for Poisson's ratio of highly nonlinear materials10.1007/BF02329817 ↗
61. Smith, T.S., Bay, B.K., 2001. Experimental measurement of strains using digital volume correlation. In: Nontraditional Methods of Sensing Stress, Strain, and Damage in Materials and Structures, vol. 2, 1323, pp. 117–126.10.1520/STP42144S ↗
62. Digital volume correlation including rotational degrees of freedom during minimization10.1007/BF02410982 ↗
63. Measurement of bone strain using electronic speckle pattern interferometry10.1166/jhs.2005.007 ↗
64. Application of an optimized digital correlation method to planar deformation analysis10.1016/0262-8856(86)90057-0 ↗
65. Using digital image correlation to determine bone surface strains during loading and after adaptation of the mouse tibia10.1016/j.jbiomech.2009.10.042 ↗
66. Tattoli, F., Pierron, F., Rotinat, R., Casavola, C., Pappalettere, C., 2010. Full-field strain measurement on titanium welds and local elasto-plastic identification with the virtual fields method. In: International Conference on Advances in Materials and Processing Technologies, Pts One and Two 1315, pp. 860–865.10.1063/1.3552559 ↗
67. Relationship between CT intensity, micro-architecture and mechanical properties of porcine vertebral cancellous bone10.1016/j.clinbiomech.2005.11.001 ↗
68. Digital image correlation: a technique for determining local mechanical conditions within early bone callus10.1016/j.medengphy.2006.08.012 ↗
69. Tissue stresses and strain in trabeculae of a canine proximal femur can be quantified from computer reconstructions10.1016/S0021-9290(98)00150-X ↗
70. A new method to determine trabecular bone elastic properties and loading using micromechanical finite-element models10.1016/0021-9290(95)80008-5 ↗
71. Thermographic stress analysis in cortical bone10.1115/1.2895421 ↗
72. VDI/VDE, 2630-1.2 Computed Tomography on Dimensional Measurement – Influencing Variables on Measurement Results and Recommendations for Computed-Tomography Dimensional Measurements, 11/2010, Beuth, Berlin.
73. A three-dimensional digital image correlation technique for strain measurements in microstructures10.1016/j.jbiomech.2003.12.036 ↗
74. Indirect determination of trabecular bone effective tissue failure properties using micro-finite element simulations10.1016/j.jbiomech.2008.02.032 ↗
75. Dependence of trabecular damage on mechanical strain10.1002/jor.1100150522 ↗
76. Wentzell, S., Nesbitt, R.S., Macione, J., Knapp, R., Kotha, S.R., 2011. Bone strain measurement using 3D digital image correlation of second harmonic generation images. In: 2011 IEEE 37th Annual Northeast Bioengineering Conference (Nebec).10.1109/NEBC.2011.5778642 ↗
77. Study of optimal subset size in digital image correlation of speckle pattern images10.1016/j.optlaseng.2007.01.012 ↗
78. Elastic modulus and hardness of cortical and trabecular bone lamellae measured by nanoindentation in the human femur10.1016/S0021-9290(99)00111-6 ↗