Wear performance of dental ceramics after grinding and polishing treatments
Source abstract
Abstract
Aim The aim of this in vitro study was to determine the two-body wear resistance of different dental ceramics after grinding and polishing treatments. Material and methods Standardized specimens were prepared from three zirconia and two veneering ceramics and were subjected to different surface treatments. Zirconia ceramics were polished, ground and repolished, veneering ceramics were ground and repolished. One zirconia ceramic was investigated with a superficial glaze. Human enamel was used for reference. Surface roughness R(a) was determined using a profilometric contact surface measurement device. Two-body wear tests were performed in a chewing simulator with steatite and enamel antagonists, respectively. Specimens were loaded pneumatically in a pin-on-block design for 1.2x10(5) mastication cycles (50 N, 1.2 Hz, lateral movement: 1 mm, mouth opening: 2 mm) under simultaneous thermal cycling (600 cycles, 5/55 °C). Wear depths of specimens were determined using a 3D laser scanning device, wear areas of steatite antagonists were measured by means of light-optical micrographs. Means and standard deviations were calculated, and statistical analysis was performed using one-way analysis of variance (ANOVA) and the Bonferroni multiple comparison test for post hoc analysis (α=0.05). Scanning electron microscopy was applied for evaluating the wear performance of ceramics and antagonists. Results No wear was found for polished, ground and repolished zirconia. Compared to the wear depths of the enamel reference with 274.1±187.4 μm versus steatite and 123.3±131.0 μm versus enamel, relative wear depths of porcelains ranged between 0.54±0.07 and 0.62±0.09 with steatite antagonists and between 0.66±0.26 and 1.04±0.27 with enamel antagonists. Relative wear areas of steatite antagonists (enamel reference: 1.25 mm(2)) varied between 0.84±0.13 and 1.90±0.29 for zirconia and between 1.97±0.38 and 2.47±0.40 for porcelains. Enamel antagonists generally showed wear, cracks or even fractures, but revealed smooth surfaces when opposed to polished/ground/repolished zirconia and ploughed surfaces when opposed to ground/repolished porcelains or glaze. Conclusions Zirconia ceramics yielded superior wear behavior and lower antagonistic wear compared to porcelains. A trend to higher ceramic and antagonistic wear was shown after grinding treatments.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Dental materials and restorations · Dental Erosion and Treatment · Dental Health and Care Utilization
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (49)
Show source-provided references
1. Clinical trials in zirconia: a systematic review
2. Investigation of human enamel wear against four dental ceramics and gold10.1016/S0300-5712(97)00041-9 ↗
3. Transformation-toughened zirconia for dental inlays, crowns and bridges: chemical stability and effect of low-temperature aging on flexural strength and surface structure10.1016/S0109-5641(01)00095-1 ↗
4. Critical effect of cubic phase on aging in 3 mol% yttria-stabilized zirconia ceramics for hip replacement prosthesis10.1016/j.biomaterials.2004.01.002 ↗
5. Laboratory simulation of Y-TZP all-ceramic crown clinical failures10.1177/0022034509333968 ↗
6. In vitro wear of composite with varied cure, filler level, and filler treatment10.1177/00220345970760071101 ↗
7. In vivo wear of enamel by a lithia disilicate-based core ceramic used for posterior fixed partial dentures: first-year results
8. Quantitative measurement of tooth and ceramic wear: in vivo study
9. Effect of surface roughness on flexural strength of veneer ceramics10.1177/154405910308201207 ↗
10. Strength, fracture toughness and microstructure of a selection of all-ceramic materials10.1016/j.dental.2003.05.002 ↗
11. Two-body wear of artificial acrylic and composite resin teeth in relation to antagonist material10.1016/S0022-3913(09)60051-2 ↗
12. How to qualify and validate wear simulation devices and methods10.1016/j.dental.2006.02.002 ↗
13. Wear of ceramic and antagonist—a systematic evaluation of influencing factors in vitro10.1016/j.dental.2007.06.016 ↗
14. Recommendations for conducting controlled clinical studies of dental restorative materials10.1007/s00784-006-0095-7 ↗
15. Effects of sintering temperature and particle size on the translucency of zirconium dioxide dental ceramic10.1007/s10856-011-4438-9 ↗
16. Covariation of some factors associated with occlusal tooth wear in a selected high-wear sample
17. Lifetime-limiting strength degradation from contact fatigue in dental ceramics10.1177/00220345000790020501 ↗
18. A study on the in-vitro wear of the natural tooth structure by opposing zirconia or dental porcelain10.4047/jap.2010.2.3.111 ↗
19. Influence of surface treatments on surface roughness, phase transformation, and biaxial flexural strength of Y-TZP ceramics10.1002/jbm.b.31477 ↗
20. Concerns of hydrothermal degradation in CAD/CAM zirconia10.1177/0022034509354193 ↗
21. Sliding contact fatigue damage in layered ceramic structures10.1177/154405910708601105 ↗
22. A study of the effects of chewing patterns on occlusal wear10.1111/j.1365-2842.2001.00761.x ↗
23. The influence of antagonist standardization on wear10.1177/00220345990780021201 ↗
24. Wear of ceramic inlays, their enamel antagonists, and luting cements10.1016/0022-3913(93)90192-Q ↗
25. Quantitative in vivo wear of human enamel10.1177/00220345890680120601 ↗
26. Zirconium dioxide based dental restorations
27. Wear in dentistry—current terminology10.1016/0300-5712(92)90125-V ↗
28. Mair, L.H., Stolarski, T.A., Vowles, R.W., Lloyd, C.H., 1996, Wear: mechanisms, manifestations and measurement, Report of a workshop, J. Dent., 24, pp. 141–148.10.1016/0300-5712(95)00043-7 ↗
29. In vitro investigation of the wear of human enamel by dental porcelain10.1016/S0022-3913(99)70280-5 ↗
30. Monoclinic phase transformations of zirconia-based dental prostheses, induced by clinically practised surface manipulations10.1016/j.actbio.2011.04.007 ↗
31. Factors affecting enamel and ceramic wear: a literature review10.1067/mpr.2002.123851 ↗
32. Wear performance of substructure ceramics and veneering porcelains10.1016/j.dental.2011.04.001 ↗
33. Wear performance of dental materials: a comparison of substructure ceramics, veneering ceramics, and non-precious alloys10.1002/adem.201180015 ↗
34. Influence of stress simulation parameters on the fracture strength of all-ceramic fixed-partial dentures10.1016/j.dental.2005.04.024 ↗
35. Approach for valuating the influence of laboratory simulation10.1016/j.dental.2008.08.009 ↗
36. Influence of the fabrication process on the in vitro performance of fixed dental prostheses with zirconia substructures10.1007/s00784-010-0469-8 ↗
37. Rosentritt, M., Preis, V., Behr, M., Hahnel, S., Handel, G., Kolbeck, C., 2011b, Two-body wear of dental porcelain and substructure oxide ceramics, Clin. Oral Investig, (In press), http://dx.doi.org/10.1007/s00784-011-0589-9.10.1007/s00784-011-0589-9 ↗
38. Influence of substructure design and spacer settings on the in vitro performance of molar zirconia crowns10.1016/j.jdent.2009.08.003 ↗
39. Randomized controlled clinical trial of zirconia-ceramic and metal-ceramic posterior fixed dental prostheses: a 3-year follow-up
40. Surface characteristics of zirconia-based posterior restorations: clinical and scanning electron microscopic analysis
41. Potential countersample materials for in vitro simulation wear testing10.1016/S0109-5641(01)00043-4 ↗
42. Clinical performance and wear characteristics of veneered lithia-disilicate-based ceramic crowns10.1016/j.dental.2007.06.033 ↗
43. Structural reliability of alumina-, feldspar-, leucite-, mica- and zirconia-based ceramics10.1016/S0300-5712(00)00030-0 ↗
44. Zirconia in dentistry: part 1. discovering the nature of an upcoming bioceramic
45. A two-body frictional wear test10.1177/00220345940730091001 ↗
46. Wear characteristics in a two-body wear test10.1016/0109-5641(94)90073-6 ↗
47. Phase stability of zirconia
48. Deep-penetrating conical cracks in brittle layers from hydraulic cyclic contact10.1002/jbm.b.30195 ↗
49. Zum Gahr · 1987