journal article·2013-01Open access

The anisotropic mechanical behaviour of passive skeletal muscle tissue subjected to large tensile strain

Michael Takaza, Kevin M. Moerman, Juliette Gindre, Garry Lyons, Ciaran K. Simms

Abstract

The passive mechanical properties of muscle tissue are important for many biomechanics applications. However, significant gaps remain in our understanding of the three-dimensional tensile response of passive skeletal muscle tissue to applied loading. In particular, the nature of the anisotropy remains unclear and the response to loading at intermediate fibre directions and the Poisson's ratios in tension have not been reported. Accordingly, tensile tests were performed along and perpendicular to the muscle fibre direction as well as at 30°, 45° and 60° to the muscle fibre direction in samples of Longissimus dorsi muscle taken from freshly slaughtered pigs. Strain was measured using an optical non-contact method. The results show the transverse or cross fibre (TT') direction is broadly linear and is the stiffest (77 kPa stress at a stretch of 1.1), but that failure occurs at low stretches (approximately λ=1.15). In contrast the longitudinal or fibre direction (L) is nonlinear and much less stiff (10 kPa stress at a stretch of 1.1) but failure occurs at higher stretches (approximatelyλ=1.65). An almost sinusoidal variation in stress response was observed at intermediate angles. The following Poisson's ratios were measured: VLT=VLT'=0.47, VTT'=0.28 and VTL=0.74. These observations have not been previously reported and they contribute significantly to our understanding of the three dimensional deformation response of skeletal muscle tissue.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Sports injuries and prevention · Tendon Structure and Treatment · Mechanics and Biomechanics Studies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (49)

Show source-provided references
1. ASTM International, 2011. Standard Test Methods for Tension Testing of Metallic Materials E8/E8M.
2. A PC-based system architecture for real-time finite element-based tool-specific surgical simulation10.1016/j.ics.2004.03.294 ↗
3. Finite element modelling of maxilloficial surgery and facial expressions, preliminary study10.1002/rcs.352 ↗
4. Passive nonlinear elastic behaviour of skeletal muscle: experimental results and model formulation10.1016/j.jbiomech.2009.08.032 ↗
5. Correlation between active and passive isometric force and intramuscular pressure in the isolated rabbit tibialis anterior muscle10.1016/S0021-9290(02)00430-X ↗
6. Model-based estimation of muscle forces exerted during movements10.1016/j.clinbiomech.2006.09.005 ↗
7. Effect of convection on osteoblastic cell growth and function in biodegradable polymer foam scaffolds10.1016/S0142-9612(00)00280-5 ↗
8. Compressive properties of soft tissues
9. Mechanical and histological characterization of the abdominal muscle. A previous step to modelling hernia surgery10.1016/j.jmbbm.2010.11.012 ↗
10. The role of extracelluar matrix composition in structure and function of bioengineered skeletal muscle10.1016/j.biomaterials.2011.01.062 ↗
11. Muscle as a collagen fiber reinforced composite: a review of force transmission in muscle and whole limb10.1016/S0021-9290(98)00186-9 ↗
12. Dynamic sagittal flexibility coefficients of the human cervical spine10.1016/j.aap.2006.10.015 ↗
13. Role of extracellular matrix in adaptation of tendon and skeletal muscle to mechanical loading10.1152/physrev.00031.2003 ↗
14. Reconsideration of the sequence of rigour mortis through post-mortem changes in adenosine nucleotides and lactic acid in different rat muscles10.1016/S0379-0738(96)02005-1 ↗
15. Connective tissue differences in the strength of cooked meat across the muscle fibre direction due to test specimen size10.1016/0309-1740(90)90002-N ↗
16. Real time simulation of nonlinear tissue response in virtual surgery using the point collocation-based method of finite spheres10.1016/j.cma.2006.05.015 ↗
17. Assessment of mechanical conditions in sub-dermal tissues during sitting: a combined experimental-MRI and finite element approach10.1016/j.jbiomech.2006.06.020 ↗
18. Strains and stresses in sub-dermal tissues of the buttocks are greater in paraplegics than in healthy during sitting10.1016/j.jbiomech.2007.10.011 ↗
19. Experimental studies on the relation between acceleration and intracranial pressure changes in man
20. Head injury prediction capability of HIC, HIP, SIMon and ULP creteria—new injury criteria for the head10.1016/j.aap.2007.12.006 ↗
21. 1997
22. 1998
23. A comparative study of several material models for prediction of hyper elastic behaviour of silicone-rubber10.1111/j.1475-1305.2006.00257.x ↗
24. Bone remodelling algorithms incorporating both strain and microdamage stimuli10.1016/j.jbiomech.2006.05.007 ↗
25. 2000
26. Meyers · 1994
27. Evaluation of a validation method for MR imaging-based motion tracking using image simulation
28. Transmission of forces within mammalian skeletal muscles10.1016/S0021-9290(98)00189-4 ↗
29. Transversely isotropic tensile material properties of skeletal muscle tissue10.1016/j.jmbbm.2009.03.004 ↗
30. Experimental test for the validation of active numerial human models10.1016/j.forsciint.2007.12.005 ↗
31. Dynamic tensile response of porcine muscle
32. Non-uniform distribution of strain during stretch of relaxed skeletal muscle fibers from rat soleus muscle10.1007/s10974-011-9250-0 ↗
33. Physical continuity of the perimysium from myofibers to tendons: involvement in lateral force transmission in skeletal muscle10.1016/j.jsb.2007.01.022 ↗
34. Purslow, P.P., 1999. The intramuscular connective tissue matrix and cell-matrix interactions in relation to meat toughness. In: Proceedings of the 45th Interantional Congress of Meat Science and Technology. Yokohama, Japan, 210e219.
35. Muscle fascia and force transmission10.1016/j.jbmt.2010.01.005 ↗
36. Raul, J., Deck, C., Ludes, B. and Willinger, R. 2008. Finite element models of the human head and their applications in forensic practice. International Journal of Legal Medicine. 10.I007.s00414-008-0248-0
37. Passive muscle stiffness may be influenced by active contractility of intramuscular connective tissue10.1016/j.mehy.2005.08.025 ↗
38. Lateral transmission of tension frog myofibers: a myofibrillar network and transverse cytoskeletal connections are possible transmitters10.1002/jcp.1041140314 ↗
39. Open problems in computational vascular biomechanics: hemodynamics and arterial wall mechanics10.1016/j.cma.2009.02.004 ↗
40. Functional morphology of the endomysium in series fibered muscles10.1002/jmor.1052120203 ↗
41. Quantifying skeletal muscle properties in cadaveric test specimens: effects of mechanical loading, postmortem time, and freezer storage10.1115/1.429621 ↗
42. A validated model of passive muscle in compression10.1016/j.jbiomech.2005.10.016 ↗
43. Viscoelastic properties of passive skeletal muscle in compression: stress-relaxation behaviour and constitutive modelling10.1016/j.jbiomech.2008.02.007 ↗
44. Viscoelastic properties of passive skeletal muscle in compression: cyclic behaviour10.1016/j.jbiomech.2009.02.022 ↗
45. Modelling the mechanics of narrowly contained soft tissues: the effects of specification of Poisson's Ratio
46. A biochemical study of certain skeletal muscle constituents in human progressive muscular dystrophy10.1172/JCI103869 ↗
47. Proportion of adipose tissue-free body mass as skeletal muscle: magnitude and constancy in men10.1002/(SICI)1520-6300(1997)9:4<487::AID-AJHB8>3.0.CO;2-T ↗
48. Structural biomechanics modulate intramuscular distribution of locally delivered drugs10.1016/j.jbiomech.2008.06.025 ↗