Fatigue strength of Co–Cr–Mo alloy clasps prepared by selective laser melting
Source abstract
Abstract
We aimed to investigate the fatigue strength of Co-Cr-Mo clasps for removable partial dentures prepared by selective laser melting (SLM). The Co-Cr-Mo alloy specimens for tensile tests (dumbbell specimens) and fatigue tests (clasp specimens) were prepared by SLM with varying angles between the building and longitudinal directions (i.e., 0° (TL0, FL0), 45° (TL45, FL45), and 90° (TL90, FL90)). The clasp specimens were subjected to cyclic deformations of 0.25mm and 0.50mm for 10(6) cycles. The SLM specimens showed no obvious mechanical anisotropy in tensile tests and exhibited significantly higher yield strength and ultimate tensile strength than the cast specimens under all conditions. In contrast, a high degree of anisotropy in fatigue performance associated with the build orientation was found. For specimens under the 0.50mm deflection, FL90 exhibited significantly longer fatigue life (205,418 cycles) than the cast specimens (112,770 cycles). In contrast, the fatigue lives of FL0 (28,484 cycles) and FL45 (43,465 cycles) were significantly shorter. The surface roughnesses of FL0 and FL45 were considerably higher than those of the cast specimens, whereas there were no significant differences between FL90 and the cast specimens. Electron backscatter diffraction (EBSD) analysis indicated the grains of FL0 showed preferential close to <001> orientation of the γ phase along the normal direction to the fracture surface. In contrast, the FL45 and FL90 grains showed no significant preferential orientation. Fatigue strength may therefore be affected by a number of factors, including surface roughness and crystal orientation. The SLM process is a promising candidate for preparing tough removable partial denture frameworks, as long as the appropriate build direction is adopted.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Dental materials and restorations · Additive Manufacturing Materials and Processes · Welding Techniques and Residual Stresses
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (58)
Show source-provided references
1. Surface roughness prediction using measured data and interpolation in layered manufacturing10.1016/j.jmatprotec.2008.02.050 ↗
2. Comparison of the bond strength of laser-sintered and cast base metal dental alloys to porcelain10.1016/j.dental.2008.03.001 ↗
3. Structural characterization of biomedical Co–Cr–Mo components produced by direct metal laser sintering10.1016/j.msec.2014.12.009 ↗
4. Masticatory function-a review of the literature: (II) Speed of movement of the mandible, rate of chewing and forces developed in chewing10.1111/j.1365-2842.1975.tb01535.x ↗
5. Clinical performance of cast clasp-retained removable partial dentures: a retrospective study
6. A systematic review of CAD/CAM fit restoration evaluations10.1111/joor.12205 ↗
7. Modelling micro geometrical profiles in fused deposition process10.1007/s00170-011-3744-1 ↗
8. Campbell · 2008
9. Canale · 2008
10. Carr · 2011 · 67
11. Roles of microstructure in fatigue crack initiation10.1016/j.ijfatigue.2009.10.005 ↗
12. Design and manufacture of customized dental implants by using reverse engineering and selective laser melting technology10.1016/j.prosdent.2014.04.026 ↗
13. Chua · 2014
14. Fatigue performance evaluation of selective laser melted Ti–6Al–4V10.1016/j.msea.2014.01.041 ↗
15. In vitro biocompatibility of CoCrMo dental alloys fabricated by selective laser melting10.1016/j.dental.2014.02.008 ↗
16. Customised titanium implant fabricated in additive manufacturing for craniomaxillofacial surgery10.1080/17452759.2014.900857 ↗
17. The analysis of the mechanical properties of F75 Co–Cr alloy for use in selective laser melting (SLM) manufacturing of removable partial dentures (RPD)
18. The influence of cooling conditions on grain size, secondary phase precipitates and mechanical properties of biomedical alloy specimens produced by investment casting10.1016/j.jmbbm.2013.04.013 ↗
19. Inconel 939 processed by selective laser melting: Effect of Microstructure and temperature on the mechanical properties under static and cyclic loading10.1016/j.msea.2013.09.025 ↗
20. Improvement of fatigue resistance and ductility of TiAl6V4 processed by selective laser melting10.1016/j.jmatprotec.2015.01.025 ↗
21. Selective laser melting technique of Co–Cr dental alloys: a review of structure and properties and comparative analysis with other available techniques10.1111/jopr.12268 ↗
22. On the mechanical behaviour of titanium alloy TiAl6V4 manufactured by selective laser melting: Fatigue resistance and crack growth performance10.1016/j.ijfatigue.2012.11.011 ↗
23. Fatigue behavior of thin-walled grade 2 titanium samples processed by selective laser melting. Application to life prediction of porous titanium implants10.1016/j.jmbbm.2013.08.011 ↗
24. Selective laser melting of aluminium alloy using a uniform beam profile10.1080/17452759.2013.869608 ↗
25. Deflection fatigue of Ti-6Al-7Nb, Co-Cr, and gold alloy cast clasps10.1016/j.prosdent.2004.11.011 ↗
26. Pre-overloading to extend fatigue life of cast clasps10.1177/154405910708600912 ↗
27. Stereo imaging and cytocompatibility of a model dental implant surface formed by direct laser fabrication10.1002/jbm.a.32033 ↗
28. Immediate restoration of fixed partial prostheses supported by one-piece narrow-diameter selective laser sintering implants: a 2-year prospective study in the posterior jaws of 16 patients10.1097/ID.0b013e31829afa9d ↗
29. Maxillary overdentures supported by four splinted direct metal laser sintering implants: a 3-year prospective clinical study10.1155/2014/252343 ↗
30. Role of strain-induced martensitic transformation on extrusion and intrusion formation during fatigue deformation of biomedical Co–Cr–Mo–N alloys10.1016/j.actamat.2014.08.039 ↗
31. The fit of cobalt-chromium three-unit fixed dental prostheses fabricated with four different techniques: a comparative in vitro study10.1016/j.dental.2010.11.015 ↗
32. A computational reduction model for appraising structural effects in selective laser melting manufacturing10.1080/17452759.2013.868005 ↗
33. CAD/CAM-fabricated implant-supported restorations: a systematic review10.1111/clr.12633 ↗
34. Marginal and internal fit of metal-ceramic crowns fabricated with a new laser melting technology10.1016/j.dental.2008.02.011 ↗
35. Ratner, B.D., Hoffman, A.S., Schoen, F.J., Lemons, J.E., 2012. Biomaterials Science, Third Edition: An Introduction to Materials in Medicine.
36. On the fatigue crack growth behavior in 316L stainless steel manufactured by selective laser melting10.1016/j.engfracmech.2014.03.008 ↗
37. Complications and failures in removable partial dentures: a clinical evaluation10.1046/j.1365-2842.2002.00898.x ↗
38. The physics of fatigue crack initiation10.1016/j.ijfatigue.2012.10.009 ↗
39. Effect of molten pool boundaries on the mechanical properties of selective laser melting parts10.1016/j.jmatprotec.2014.06.002 ↗
40. Additive CAD/CAM process for dental prostheses10.1111/j.1532-849X.2010.00623.x ↗
41. Laser and electron-beam powder-bed additive manufacturing of metallic implants: a review on processes, materials and designs
42. Microstructure and tensile properties of iron parts fabricated by selective laser melting10.1016/j.optlastec.2013.09.017 ↗
43. Surface roughness analysis, modelling and prediction in selective laser melting10.1016/j.jmatprotec.2012.11.011 ↗
44. The application of rapid prototyping in prosthodontics10.1111/j.1532-849X.2012.00888.x ↗
45. Build direction dependence of microstructure and high-temperature tensile property of Co–Cr–Mo alloy fabricated by electron beam melting10.1016/j.actamat.2013.10.017 ↗
46. Microstructures and mechanical properties of Co–29Cr–6Mo alloy fabricated by selective laser melting process for dental applications10.1016/j.jmbbm.2013.01.021 ↗
47. Rapid prototyping technologies and their applications in prosthodontics, a review of literature
48. Direct laser metal sintering as a new approach to fabrication of an isoelastic functionally graded material for manufacture of porous titanium dental implants10.1016/j.dental.2008.03.029 ↗
49. Selective laser melting of biocompatible metals for rapid manufacturing of medical parts10.1108/13552540710776142 ↗
50. The effect of low cooling rates on dendrite morphology during directional solidification in Mg–Gd alloys: In situ X-ray radiographic observation10.1016/j.matlet.2015.10.101 ↗
51. Use of CAD/CAM technology to fabricate a removable partial denture framework10.1016/j.prosdent.2006.05.029 ↗
52. Evaluation of the mechanical properties and porcelain bond strength of cobalt-chromium dental alloy fabricated by selective laser melting10.1016/j.prosdent.2013.09.011 ↗
53. Surface characteristics and corrosion properties of selective laser melted Co-Cr dental alloy after porcelain firing10.1016/j.dental.2013.11.013 ↗
54. Evaluation of residual stress in stainless steel 316L and Ti6Al4V samples produced by selective laser melting10.1080/17452759.2015.1026045 ↗
55. Yap, C.Y., Chua, C.K., Dong, Z.L., Liu, Z.H., Zhang, D.,.Q., 2014. State-of-the-art review on selective laser melting of non-ferrous metals. In: Proceedings of the 1st International Conference on Progress in Additive Manufacturing. 26–28.10.3850/978-981-09-0446-3_035 ↗
56. Usage and status of cobalt-chromium removable partial dentures 5-6 years after placement10.1046/j.1365-2842.2002.00846.x ↗
57. Low-cycle fatigue-cracking mechanisms in fcc crystalline materials10.1080/14786435.2010.518169 ↗
58. Study on fatigue threshold behavior and fatigue crack propagation in a cast Co–Cr–Mo alloy used for surgical implants10.1111/j.1460-2695.1989.tb00537.x ↗