Laser processed TiN reinforced Ti6Al4V composite coatings
Source abstract
Abstract
The purpose of this first generation investigation is to evaluate fabrication, in vitro cytotoxicity, cell-material interactions and tribological performance of TiN particle reinforced Ti6Al4V composite coatings for potential wear resistant load bearing implant applications. The microstructural analysis of the composites was performed using scanning electron microscope and phase analysis was done with X-ray diffraction. In vitro cell-material interactions, using human fetal osteoblast cell line, have been assessed on these composite coatings and compared with Ti6Al4V alloy control samples. The tribological performance of the coatings were evaluated, in simulated body fluids, up to 1000 m sliding distance under 10 N normal load. The results show that the composite coatings contain distinct TiN particles embedded in α+β phase matrix. The average top surface hardness of Ti6Al4V alloy increased from 394±8 HV to 1138±61 HV with 40 wt% TiN reinforcement. Among the composite coatings, the coatings reinforced with 40 wt% TiN exhibited the highest wear resistance of 3.74×10(-6) mm(3)/Nm, which is lower than the wear rate, 1.04×10(-5) mm(3)/Nm, of laser processed CoCrMo alloy tested under identical experimental conditions. In vitro biocompatibility study showed that these composite coatings were non-toxic and provides superior cell-material interactions compared to Ti6Al4V control, as a result of their high surface energy. In summary, excellent in vitro wear resistance and biocompatibility of present laser processed TiN reinforced Ti6Al4V alloy composite coatings clearly show their potential as wear resistant contact surfaces for load bearing implant applications.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Metal and Thin Film Mechanics · Tribology and Wear Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (45)
Show source-provided references
1. Fabrication of porous NiTi shape memory alloy structures using laser engineered net shaping10.1002/jbm.b.31238 ↗
2. Engineered porous metals for implants10.1007/s11837-008-0059-2 ↗
3. Laser assisted Zr/ZrO2 coating on Ti for load-bearing implants10.1016/j.actbio.2009.03.032 ↗
4. Application of laser engineered net shaping (LENS) to manufacture porous and functionally graded structures for load bearing implants10.1007/s10856-008-3478-2 ↗
5. Surface engineering of titanium with nitrogen10.1179/sur.1986.2.2.133 ↗
6. In vitro biological and tribological properties of transparent magnesium aluminate (Spinel) and aluminum oxynitride (AlON)10.1007/s10856-011-4332-5 ↗
7. Role of surface charge and wettability on early stage mineralization and bone cell-materials interactions of polarized hydroxyapatite10.1016/j.actbio.2009.02.023 ↗
8. Wear-accelerated corrosion of Ti–6Al–4V and nitrogen-ion-implanted Ti–6Al–4V: mechanisms and influence of fixed-stress magnitude10.1002/jbm.820210309 ↗
9. The effect of surface chemistry and structure of titanium nitride (TiN) films on primary hippocampal cells10.1016/S1389-0344(02)00021-7 ↗
10. Surface modification of laser processed porous titanium for load bearing implants10.1016/j.scriptamat.2008.06.018 ↗
11. TiN coating: surface characterization and haemocompatibility10.1016/0142-9612(93)90019-X ↗
12. In vitro wear rate and Co ion release of compositionally and structurally graded CoCrMo–Ti6Al4V structures10.1016/j.msec.2010.07.009 ↗
13. Enhanced wear resistance of titanium surfaces by a new thermal oxidation treatment10.1016/S0043-1648(99)00359-2 ↗
14. Mechanical behaviour, wear surface morphology, and clinical performance of UHMWPE acetabular components after 10 years of implantation10.1016/S0043-1648(01)00616-0 ↗
15. Characterization of surface oxide films on titanium and adhesion of osteoblast10.1016/S0142-9612(03)00366-1 ↗
16. Microstructural and corrosion evaluation of laser surface nitrided Ti–13Nb–13Zr alloy10.1179/026708404225010595 ↗
17. Ti based biomaterials, the ultimate choice for orthopedic implants—a review10.1016/j.pmatsci.2008.06.004 ↗
18. PIRAC Ti nitride coated Ti–6Al–4V head against UHMWPE acetabular cup–hip wear simulator study10.1023/B:JMSM.0000021096.77850.c5 ↗
19. Evaluation of metallic and polymeric biomaterial surface energy and surface roughness characteristics for directed cell adhesion10.1089/107632700300003297 ↗
20. Wear analysis of a retrieved hip implant with titanium nitride coating10.1016/S0883-5403(97)90164-9 ↗
21. Hardness and corrosion protection enhancement behaviour of surgical implant surfaces treated with ceramic thin films10.1016/S0257-8972(99)00221-2 ↗
22. Clinical reviews: particulate debris and failure of total hip replacements10.1002/jab.770040310 ↗
23. Kechemair, D., Laurens, P., Sabatier, L., Ricaud, J.P., 1992. In: Matsunawa A., Katayama S., (Eds.), Proc. Laser Advanced Mater. Processing‘92, High Temperature Soc. of Japan, vol. 1, p. 281.
24. Microstructural characterization of laser nitrided titanium10.1016/0956-716X(95)00238-Q ↗
25. Implant retrieval studies of the wear and loosening of prosthetic joints: a review10.1016/S0043-1648(00)00370-7 ↗
26. Diamond, diamond-like and titanium nitride biocompatible coatings for human body parts10.1016/0921-5107(94)90193-7 ↗
27. Nitride formation in titanium based substrates during laser surface melting in nitrogen-argon atmospheres10.1016/S1359-6454(98)00369-3 ↗
28. Estimation of the surface free energy of polymers10.1002/app.1969.070130815 ↗
29. Titanium nitride ceramic film against polyethylene. A 48 million cycle wear test
30. Bioactivity of TiN-coated titanium implants10.1016/j.actamat.2003.11.020 ↗
31. The in-vivo wear performance of prosthetic femoral heads with titanium nitride coating10.1016/S0142-9612(99)00246-X ↗
32. Osteoclast adhesion and activity on synthetic hydroxyapatite, carbonated hydroxyapatite, and natural calcium carbonate: relationship to surface energies10.1002/(SICI)1097-4636(199905)45:2<140::AID-JBM9>3.0.CO;2-I ↗
33. Wear resistance of the nitrogen diffusion hardening of the Ti6Al4V alloy10.1016/S0021-9290(98)80100-0 ↗
34. Interactions in titanium matrix composites reinforced by titanium compounds by conventional PM route10.4028/www.scientific.net/MSF.534-536.817 ↗
35. Mechanical and microstructural properties of titanium matrix composites reinforced by TiN particles10.4028/www.scientific.net/MSF.534-536.825 ↗
36. Compositionally graded hydroxyapatite/tricalcium phosphate coating on Ti by laser and induction plasma10.1016/j.actbio.2010.09.016 ↗
37. Wear simulation of total hip prostheses with polyethylene against CoCrMo, alumina and diamond-like carbon10.1016/S0142-9612(00)00306-9 ↗
38. Studies on the corrosion and wear behavior of the laser nitrided biomedical titanium and its alloys10.1016/j.msec.2009.12.004 ↗
39. Study of the surface layer formed by the laser processing of Ti–6Al–4V alloy in a dilute nitrogen environment10.1016/S0924-0136(01)00595-7 ↗
40. A comparative study of titanium nitrides, TiN, TiNbN and TiCN, as coatings for biomedical applications10.1016/j.surfcoat.2009.06.010 ↗
41. Tribological characterisation of diamond-like carbon coatings on Co–Cr–Mo alloy for orthopaedic applications10.1016/S0257-8972(01)01425-6 ↗
42. Phase analysis, microhardness and tribological behaviour of Ti–6Al–4V after ion implantation of nitrogen in connection with its application for hip-joint prosthesis10.1016/0040-6090(96)80028-9 ↗
43. Laser surface alloying of titanium substrates with carbon and nitrogen10.1179/sur.1985.1.1.23 ↗
44. Sliding wear studies of selected nitride coatings and their potential for long-term use in orthopaedic applications10.1243/0954411981534088 ↗
45. Wriedt · 1987