journal article·2014-01

In situ synthesized TiB–TiN reinforced Ti6Al4V alloy composite coatings: Microstructure, tribological and in-vitro biocompatibility

Mitun Das, Kaushik Bhattacharya, Stanley A. Dittrick, Chitra Mandal, Vamsi Krishna Balla, T.S. Sampath Kumar, Amit Bandyopadhyay, Indranil Manna

Publisher page

Abstract

Wear resistant TiB-TiN reinforced Ti6Al4V alloy composite coatings were deposited on Ti substrate using laser based additive manufacturing technology. Ti6Al4V alloy powder premixed with 5wt% and 15wt% of boron nitride (BN) powder was used to synthesize TiB-TiN reinforcements in situ during laser deposition. Influences of laser power, scanning speed and concentration of BN on the microstructure, mechanical, in vitro tribological and biological properties of the coatings were investigated. Microstructural analysis of the composite coatings showed that the high temperature generated due to laser interaction with Ti6Al4V alloy and BN results in situ formation of TiB and TiN phases. With increasing BN concentration, from 5wt% to 15wt%, the Young's modulus of the composite coatings, measured by nanoindentation, increased from 170±5GPa to 204±14GPa. In vitro tribological tests showed significant increase in the wear resistance with increasing BN concentration. Under identical test conditions TiB-TiN composite coatings with 15wt% BN exhibited an order of magnitude less wear rate than CoCrMo alloy-a common material for articulating surfaces of orthopedic implants. Average top surface hardness of the composite coatings increased from 543±21HV to 877±75HV with increase in the BN concentration. In vitro biocompatibility and flow cytometry study showed that these composite coatings were non-toxic, exhibit similar cell-materials interactions and biocompatibility as that of commercially pure titanium (CP-Ti) samples. In summary, excellent in vitro wear resistance, high stiffness and suitable biocompatibility make these composite coatings as a potential material for load-bearing articulating surfaces towards orthopaedic implants.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Metal and Thin Film Mechanics · Orthopaedic implants and arthroplasty · Advanced materials and composites

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (39)

Show source-provided references
1. Laser processed TiN reinforced Ti6Al4V composite coatings10.1016/j.jmbbm.2011.09.007 ↗
2. Application of Laser Engineered Net Shaping (LENS) to manufacture porous and functionally graded structures for load bearing implants
3. Comparison of microstructural evolution in laser deposited and arc-melted in situ Ti–TiB composites10.1007/s11661-004-0162-0 ↗
4. Direct laser deposition of in situ Ti–6Al–4V–TiB composites10.1016/S0921-5093(03)00299-5 ↗
5. Microstructure and properties of titanium nitride and titanium diboride-based composites10.4028/www.scientific.net/KEM.175-176.139 ↗
6. Apoptotic effects of mahanine on human leukemic cells are mediated through crosstalk between Apo-1/Fas signaling and the Bid protein and via mitochondrial pathways10.1016/j.bcp.2009.09.007 ↗
7. Diode laser assisted surface nitriding of Ti–6Al–4V: properties of nitrided surface10.1007/s11661-009-0021-0 ↗
8. Toughening mechanisms in iron-containing hydroxyapatite/titanium composites10.1016/j.biomaterials.2009.11.046 ↗
9. Laser processing of in situ synthesized TiB–TiN reinforced Ti6Al4V alloy coatings10.1016/j.scriptamat.2012.01.010 ↗
10. Laser processing of SiC particle reinforced coating on titanium10.1016/j.scriptamat.2010.04.044 ↗
11. Reaction of titanium with boron nitride under self-propagating high-temperature synthesis conditions10.1023/A:1011359822664 ↗
12. In situ TiBw/Ti–6Al–4V composites with novel reinforcement architecture fabricated by reaction hot pressing10.1016/j.scriptamat.2009.02.032 ↗
13. Clinical reviews: particulate debris and failure of total hip replacements10.1002/jab.770040310 ↗
14. The evolution of microstructure in a laser clad TiB–Ti composite coating10.1016/S1359-6454(02)00475-5 ↗
15. Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 203010.2106/00004623-200704000-00012 ↗
16. The operation of the century: total hip replacement10.1016/S0140-6736(07)60457-7 ↗
17. Influence of in situ TiB reinforcements and role of heat treatment on mechanical properties and biocompatibility of β Ti-alloys10.1016/j.jmbbm.2012.02.014 ↗
18. The influence of heat treatment and role of boron on sliding wear behaviour of β-type Ti–35Nb–7.2Zr–5.7Ta alloy in dry condition and in simulated body fluids10.1016/j.jmbbm.2010.10.007 ↗
19. Direct materials deposition: designed macro and microstructure10.1007/s100190050137 ↗
20. Laser processing of materials10.1007/BF02706446 ↗
21. Evaluations of metabolic activities as biocompatibility tools: a study of individual ion's effect on fibroblasts10.1016/S0109-5641(99)90023-4 ↗
22. Plasma surface modification of titanium by TiB precipitation for biomedical applications10.1016/j.surfcoat.2011.07.027 ↗
23. Sliding wear resistance of metal matrix composite layers prepared by high power laser10.1016/j.surfcoat.2004.09.003 ↗
24. An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experiments10.1557/JMR.1992.1564 ↗
25. Bioactivity of TiN-coated titanium implants10.1016/j.actamat.2003.11.020 ↗
26. Reactive hot pressing of titanium nitride–titanium diboride composites at moderate pressures and temperatures10.1111/j.1151-2916.2004.tb06333.x ↗
27. Mitochondrial membrane potential monitored by JC-1 dye10.1016/0076-6879(95)60154-6 ↗
28. Modified annexin V/propidium iodide apoptosis assay for accurate assessment of cell death
29. Wear resistance of laser-deposited boride reinforced Ti-Nb–Zr–Ta alloy composites for orthopedic implants10.1016/j.msec.2007.04.029 ↗
30. Hip implants: paper V physiological effects10.1016/j.matdes.2004.10.028 ↗
31. Oxidative inhibition of Hsp90 disrupts the super-chaperone complex and attenuates pancreatic adenocarcinoma in vitro and in vivo10.1002/ijc.27687 ↗
32. Biological interactions of dental cast alloys with oral tissues10.1016/S0109-5641(01)00063-X ↗
33. Failure rates of stemmed metal-on-metal hip replacements: analysis of data from the National Joint Registry of England and Wales10.1016/S0140-6736(12)60353-5 ↗
34. What's next? Alternative materials for articulation in total joint replacement10.1016/j.actbio.2012.03.029 ↗
35. Simulation of crack propagating in discontinuously reinforced metal matrix composite10.1007/s11661-997-0173-8 ↗
36. Direct laser fabrication of Ti6Al4V/TiB10.1016/j.jmatprotec.2007.05.024 ↗
37. Three-dimensional dynamic hip contact area and pressure distribution during activities of daily living10.1016/j.jbiomech.2005.06.026 ↗
38. Phase diagram of binary alloys, Science and technology press of Shanghai
39. Enhancing the microstructure and properties of titanium alloys through nitriding and other surface engineering methods10.1016/j.surfcoat.2004.07.115 ↗