journal article·2018-04Open access

Effect of porous orthopaedic implant material and structure on load sharing with simulated bone ingrowth: A finite element analysis comparing titanium and PEEK

R. Dana Carpenter, Brett S. Klosterhoff, F. Brennan Torstrick, Kevin T. Foley, J. Kenneth Burkus, Christopher S.D. Lee, Ken Gall, Robert E. Guldberg, David L. Safranski

Abstract

Osseointegration of load-bearing orthopaedic implants, including interbody fusion devices, is critical to long-term biomechanical functionality. Mechanical loads are a key regulator of bone tissue remodeling and maintenance, and stress-shielding due to metal orthopaedic implants being much stiffer than bone has been implicated in clinical observations of long-term bone loss in tissue adjacent to implants. Porous features that accommodate bone ingrowth have improved implant fixation in the short term, but long-term retrieval studies have sometimes demonstrated limited, superficial ingrowth into the pore layer of metal implants and aseptic loosening remains a problem for a subset of patients. Polyether-ether-ketone (PEEK) is a widely used orthopaedic material with an elastic modulus more similar to bone than metals, and a manufacturing process to form porous PEEK was recently developed to allow bone ingrowth while preserving strength for load-bearing applications. To investigate the biomechanical implications of porous PEEK compared to porous metals, we analyzed finite element (FE) models of the pore structure-bone interface using two clinically available implants with high (> 60%) porosity, one being constructed from PEEK and the other from electron beam 3D-printed titanium (Ti). The objective of this study was to investigate how porous PEEK and porous Ti mechanical properties affect load sharing with bone within the porous architectures over time. Porous PEEK substantially increased the load share transferred to ingrown bone compared to porous Ti under compression (i.e. at 4 weeks: PEEK = 66%; Ti = 13%), tension (PEEK = 71%; Ti = 12%), and shear (PEEK = 68%; Ti = 9%) at all time points of simulated bone ingrowth. Applying PEEK mechanical properties to the Ti implant geometry and vice versa demonstrated that the observed increases in load sharing with PEEK were primarily due to differences in intrinsic elastic modulus and not pore architecture (i.e. 4 weeks, compression: PEEK material/Ti geometry = 53%; Ti material/PEEK geometry = 12%). Additionally, local tissue energy effective strains on bone tissue adjacent to the implant under spinal load magnitudes were over two-fold higher with porous PEEK than porous Ti (i.e. 4 weeks, compression: PEEK = 784 ± 351 microstrain; Ti = 180 ± 300 microstrain; and 12 weeks, compression: PEEK = 298 ± 88 microstrain; Ti = 121 ± 49 microstrain). The higher local strains on bone tissue in the PEEK pore structure were below previously established thresholds for bone damage but in the range necessary for physiological bone maintenance and adaptation. Placing these strain magnitudes in the context of literature on bone adaptation to mechanical loads, this study suggests that porous PEEK structures may provide a more favorable mechanical environment for bone formation and maintenance under spinal load magnitudes than currently available porous 3D-printed Ti, regardless of the level of bone ingrowth.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Bone Tissue Engineering Materials · Titanium Alloys Microstructure and Properties

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (54)

Show source-provided references
1. Osteoinduction, osteoconduction and osseointegration
2. Short-term bone formation is greatest within high strain regions of the human distal radius: a prospective pilot study10.1115/1.4028847 ↗
3. Human histology of the bone-porous metal implant interface10.3928/0147-7447-19840901-05 ↗
4. Producing and avoiding stress shielding. Laboratory and clinical observations of noncemented total hip arthroplasty10.1097/00003086-199201000-00010 ↗
5. Osseointegration and its experimental background10.1016/S0022-3913(83)80101-2 ↗
6. The rate of bone ingrowth into porous metal10.1002/jbm.820100210 ↗
7. Fatigue behavior of adult cortical bone: the influence of mean strain and strain range10.3109/17453678108992136 ↗
8. Interbody spacer material properties and design conformity for reducing subsidence during lumbar interbody fusion10.1115/1.4036312 ↗
9. Total shoulder arthroplasty: long-term survivorship, functional outcome, and quality of life10.1016/j.jse.2005.02.009 ↗
10. Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding, and clinical results10.1302/0301-620X.69B1.3818732 ↗
11. High-strength, surface-porous polyether-ether-ketone for load-bearing orthopedic implants10.1016/j.actbio.2014.11.030 ↗
12. Quantifying the strain history of bone: spatial uniformity and self-similarity of low-magnitude strains10.1016/S0021-9290(99)00210-9 ↗
13. Bone ‘mass' and the ‘mechanostat’: a proposal10.1002/ar.1092190104 ↗
14. From Wolff's law to the Utah paradigm: insights about bone physiology and its clinical applications10.1002/ar.1049 ↗
15. Clinical performances of ingrowth surfaces10.1097/00003086-199203000-00007 ↗
16. Gibson · 1999
17. Trabecular bone adaptation to variations in porous-coated implant topology10.1016/S0021-9290(96)00106-6 ↗
18. Preliminary evaluation of porous metal surfaced titanium for orthopedic implants10.1002/jbm.820040407 ↗
19. WHAT implant factors affect bone ingrowth in retrieved porous tantalum hip implants?
20. Bone ingrowth in well-fixed retrieved porous tantalum implants10.1016/j.arth.2013.01.035 ↗
21. Is there a difference in bone ingrowth in modular versus monoblock porous tantalum tibial trays?10.1016/j.arth.2015.01.010 ↗
22. Direct three-dimensional morphometric analysis of human cancellous bone: microstructural data from spine, femur, iliac crest, and calcaneus10.1359/jbmr.1999.14.7.1167 ↗
23. Porous implant systems for prosthesis stabilization10.1097/00003086-197211000-00029 ↗
24. Adaptive bone-remodeling theory applied to prosthetic-design analysis10.1016/0021-9290(87)90030-3 ↗
25. The relationship between stress shielding and bone resorption around total hip stems and the effects of flexible materials
26. Bone ingrowth in retrieved bryan cervical disc prostheses10.1097/01.brs.0000186322.61823.f3 ↗
27. The epidemiology of failure in total knee arthroplasty
28. Implant fixation by bone ingrowth10.1016/S0883-5403(99)90063-3 ↗
29. Material and mechanobiological considerations for bone regeneration
30. PEEK biomaterials in trauma, orthopedic, and spinal implants10.1016/j.biomaterials.2007.07.013 ↗
31. Outcome after total ankle arthroplasty—results and findings from worldwide arthroplasty registers10.1007/s00264-013-1981-7 ↗
32. Experimental and clinical performance of porous tantalum in orthopedic surgery10.1016/j.biomaterials.2006.04.041 ↗
33. Porous metal for orthopedics implants
34. Bone strain gage data and theoretical models of functional adaptation10.1016/0021-9290(94)00085-I ↗
35. Mechanical microenvironments and protein expression associated with formation of different skeletal tissues during bone healing10.1007/s10237-015-0670-4 ↗
36. Dependence of yield strain of human trabecular bone on anatomic site10.1016/S0021-9290(01)00011-2 ↗
37. Stress shielding and bone resorption in shoulder arthroplasty10.1067/mse.2003.22 ↗
38. Mechanical signals as anabolic agents in bone10.1038/nrrheum.2009.239 ↗
39. Observations on the effect of movement on bone ingrowth into porous-surfaced implants10.1097/00003086-198607000-00023 ↗
40. Nonlinear dependence of loading intensity and cycle number in the maintenance of bone mass and morphology10.1002/jor.1100160414 ↗
41. Regulation of bone mass by mechanical strain magnitude10.1007/BF02553711 ↗
42. Kappa Delta Award paper. Osteoregulatory nature of mechanical stimuli: function as a determinant for adaptive remodeling in bone10.1002/jor.1100050217 ↗
43. Porous titanium scaffolds fabricated using a rapid prototyping and powder metallurgy technique10.1016/j.biomaterials.2008.05.032 ↗
44. Revision surgery after total joint arthroplasty: a complication-based analysis using worldwide arthroplasty registers10.1016/j.arth.2013.01.012 ↗
45. Tribocorrosion behavior of veneering biomedical PEEK to Ti6Al4V structures10.1016/j.jmbbm.2015.09.010 ↗
46. Local mechanical stimuli regulate bone formation and resorption in mice at the tissue level10.1371/journal.pone.0062172 ↗
47. Determinants of stress shielding: design versus materials versus interface10.1097/00003086-199201000-00020 ↗
48. Bone ingrowth and wear debris in well-fixed cementless porous-coated tibial components removed from patients10.1016/S0883-5403(05)80122-6 ↗
49. Aseptic loosening, not only a question of wear: a review of different theories10.1080/17453670610045902 ↗
50. Getting PEEK to stick to bone: the development of porous PEEK for interbody fusion devices
51. Total hip arthroplasties: what are the reasons for revision?10.1007/s00264-007-0364-3 ↗
52. Deriving tissue density and elastic modulus from microCT bone scans10.1016/j.bone.2011.07.021 ↗
53. Rapid prototyping: porous titanium alloy scaffolds produced by selective laser melting for bone tissue engineering10.1089/ten.tec.2008.0288 ↗
54. Micromotion-induced strain fields influence early stages of repair at bone-implant interfaces10.1016/j.actbio.2013.01.014 ↗