Age-related variations in the biomechanical properties of human sclera
Source abstract
Abstract
This study examined age-related changes in biomechanical behaviour in the anterior, equatorial and posterior regions of the human sclera (white of the eye). Circumferential strip specimens were extracted from areas close to the limbus, equator and posterior pole in 45 donor scleras ranging in age between 51 and 84 years. The strips were subjected to cycles of uniaxial tension loading at a strain rate of 8% per minute while monitoring their load-deformation behaviour. All specimens demonstrated nonlinear behaviour with an initially low tangent modulus (a measure of material stiffness) increasing under higher stresses. The average ratios between the tangent modulus at a high stress of 1 MPa and that at a low stress of 0.05 MPa were 11.2±1.7, 12.0±1.7 and 12.4±1.5 for anterior, equatorial and posterior specimens, respectively. Stiffening was observed with age in all regions, but it was statistically significant only in the anterior region (P<0.01). Anterior specimens showed the largest stiffness growth with advancing age in both the initial, matrix regulated phase of behaviour (0.32 MPa/decade), and the final, collagen regulated phase (3.97 MPa/decade), followed by equatorial (0.27 and 2.15 MPa/decade) then posterior specimens (0.14 and 0.26 MPa/decade). The stress-strain behaviour of scleral tissue exhibits increasing stiffness with higher age. In addition to a regional variation of material stiffness, the rate of stiffness growth with age also varies between regions.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Automotive and Human Injury Biomechanics · Effects of Vibration on Health · Tendon Structure and Treatment
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (58)
Show source-provided references
1. Influence of age, gender and iris color on mechanical and chemical sensitivity of the cornea and conjunctiva10.1016/j.exer.2006.04.018 ↗
2. X-ray scattering used to map the preferred collagen orientation in the human cornea and limbus10.1016/j.str.2004.01.002 ↗
3. Age related compliance of the lamina cribrosa in human eyes10.1136/bjo.84.3.318 ↗
4. Diffusion of high molecular weight compounds through sclera
5. A study of biochemical and biomechanical qualities of normal and myopic eye sclera in humans of different age groups
6. Collagen fibrils appear more closely packed in the prepupillary cornea: optical and biomechanical implications10.1167/iovs.03-0131 ↗
7. Mapping collagen organization in the human cornea: left and right eyes are structurally distinct10.1167/iovs.05-0893 ↗
8. Full-field deformation of bovine cornea under constrained inflation conditions10.1016/j.biomaterials.2008.06.011 ↗
9. Aging, and crosslinking in mammalian collagen10.1080/03610737708257091 ↗
10. Role of preconditioning and recovery time in repeated testing of aortic valve tissues: validation through quasilinear viscoelastic theory10.1114/1.1310221 ↗
11. Biomechanics of the human posterior sclera: age- and glaucoma-related changes measured using inflation testing10.1167/iovs.11-8009 ↗
12. Physiopathologic aspects of scleral stress–strain
13. Tensile mechanical and creep properties of Descemet's membrane and lens capsule10.1016/j.exer.2004.05.014 ↗
14. Collagen fibril orientation in the human corneal stroma and its implication in keratoconus
15. Viscoelastic material properties of the peripapillary sclera in normal and early-glaucoma monkey eyes10.1167/iovs.04-0114 ↗
16. Effects of scleral stiffness properties on optic nerve head biomechanics10.1007/s10439-009-9879-7 ↗
17. Biaxial mechanical testing of human sclera10.1016/j.jbiomech.2010.02.031 ↗
18. Mechanical anisotropy of porcine cornea and correlation with stromal microstructure10.1016/j.exer.2009.01.010 ↗
19. Biomechanical properties of human and porcine corneas10.1016/j.exer.2008.02.006 ↗
20. Comparative study of corneal strip extensometry and inflation tests10.1098/rsif.2005.0034 ↗
21. Experimental assessment of corneal anisotropy10.3928/1081597X-20080201-09 ↗
22. Regional variation in the biomechanical properties of the human sclera10.1016/j.exer.2010.02.010 ↗
23. Characterization of age-related variation in corneal biomechanical properties10.1098/rsif.2010.0108 ↗
24. Numerical modelling of corneal biomechanical behaviour10.1080/10255840600976013 ↗
25. Experimental assessment of human corneal hysteresis10.1080/02713680701882519 ↗
26. Regional variations in mechanical strain in the posterior human sclera10.1167/iovs.12-9668 ↗
27. A comparison of the elastic properties of human choroid and sclera10.1016/0014-4835(88)90053-X ↗
28. Imaging sclera with hard X-ray microscopy10.1016/j.micron.2011.01.012 ↗
29. Effects of storage time on the mechanical properties of rabbit peripapillary sclera after enucleation10.1080/02713680701273792 ↗
30. Peripapillary and posterior scleral mechanics-part II: experimental and inverse finite element characterization10.1115/1.3113683 ↗
31. Girard, M.J., Suh, J.K., Bottlang, M., Burgoyne, C.F., Downs, J.C., 2009b. Scleral biomechanics in the aging monkey eye. Investigative Ophthalmology & Visual Science 50, 5226–523710.1167/iovs.08-3363 ↗
32. Surface characterisation and biomechanical analysis of the sclera by atomic force microscopy10.1016/j.jmbbm.2010.12.011 ↗
33. Second harmonic generation imaging of collagen fibrils in cornea and sciera10.1364/OPEX.13.005791 ↗
34. Strip extensiometry for comparison of the mechanical response of bovine, rabbit, and human corneas10.1115/1.2891373 ↗
35. The three-dimensional organization of collagen fibrils in the human cornea and sclera
36. The relative effects of corneal thickness and age on Goldmann applanation tonometry and dynamic contour tonometry10.1136/bjo.2005.075580 ↗
37. Ageing of the human corneal stroma: structural and biochemical changes10.1016/0925-4439(92)90041-K ↗
38. Abnormal rubbing and keratectasia10.1097/ICL.0b013e31814fb64b ↗
39. Corneal and scleral collagens—a microscopist's perspective10.1016/S0968-4328(00)00041-X ↗
40. The inflation response of the posterior bovine sclera10.1016/j.actbio.2010.06.007 ↗
41. Newell, F.W., 1986. Ophthalmology Principles and Concepts, 6th Edition (ed.) The C.V. Mosby Company, St.Louis.
42. The influence of gripping techniques on the tensile properties of tendons10.1243/095441105X34239 ↗
43. Dimensions of the human sclera: thickness measurement and regional changes with axial length10.1016/j.exer.2009.11.001 ↗
44. Human sclera: thickness and surface area10.1016/S0002-9394(99)80096-8 ↗
45. Form deprivation myopia: elastic properties of sclera10.1046/j.1475-1313.1995.9500062i.x ↗
46. The effect of changing intraocular pressure on the corneal and scleral curvatures in the fresh porcine eye10.1136/bjo.2006.110221 ↗
47. Quantitative study of collagen and elastin of the optic nerve head and sclera in human and experimental monkey glaucoma10.3109/02713689109013884 ↗
48. Proteoglycan composition in the human sclera during growth and aging
49. The sclera and myopia10.1016/j.exer.2005.08.009 ↗
50. Structural factors that mediate scleral stiffness10.1167/iovs.08-1970 ↗
51. Factors influencing optic nerve head biomechanics10.1167/iovs.05-0541 ↗
52. Finite element modeling of optic nerve head biomechanics10.1167/iovs.04-0133 ↗
53. Mechanical properties of tendons: changes with sterilization and preservation10.1115/1.2795946 ↗
54. Exogenous collagen cross-linking reduces scleral permeability: modeling the effects of age-related cross-link accumulation10.1167/iovs.08-2300 ↗
55. Scleral structure, organisation and disease. A review10.1016/S0014-4835(03)00212-4 ↗
56. Collagen crosslinking of human and porcine sclera10.1016/j.jcrs.2003.11.032 ↗
57. Nonlinear material properties of intact cornea and sclera10.1016/0014-4835(72)90139-X ↗
58. A comparison of biomechanical properties between human and porcine cornea10.1016/S0021-9290(00)00219-0 ↗