journal article·2021-09Open access

Mechanical interaction between additive-manufactured metal lattice structures and bone in compression: implications for stress shielding of orthopaedic implants

Erica Liverani, Giulia Rogati, Stefania Pagani, Silvia Brogini, Alessandro Fortunato, Paolo Caravaggi

Abstract

One of the main biomechanical causes for aseptic failure of orthopaedic implants is the stress shielding. This is caused by an uneven load distribution across the bone normally due to a stiff metal prosthesis component, leading to periprosthetic bone resorption and to implant loosening. To reduce the stress shielding and to improve osseointegration, biocompatible porous structures suitable for orthopaedic applications have been developed. Aim of this study was to propose a novel in-vitro model of the mechanical interaction between metal lattice structures and bovine cortical bone in compression. Analysis of the strain distribution between metal structure and bone provides useful information on the potential stress shielding of orthopaedic implants with the same geometry of the porous scaffold. Full density and lattice structures obtained by the repetition of 1.5 mm edge cubic elements via Laser Powder Bed Fusion of CoCrMo powder were characterized for mechanical properties using standard compressive testing. The two porous geometries were characterized by 750 μm and 1000 μm pores resulting in a nominal porosity of 43.5% and 63.2% respectively. Local deformation and strains of metal samples coupled with fresh bovine cortical bone samples were evaluated via Digital Image Correlation analysis up to failure in compression. Visualization and quantification of the local strain gradient across the metal-bone interface was used to assess differences in mechanical behaviour between structures which could be associated to stress-shielding. Overall stiffness and local mechanical properties of lattice and bone were consistent across samples. Full-density metal samples appeared to rigidly transfer the compression force to the bone which was subjected to large deformations (2.2 ± 0.3% at 15 kN). Larger porosity lattice was associated to lower stiffness and compressive modulus, and to a smoother load transfer to the bone. While tested on a limited sample size, the proposed in-vitro model appears robust and repeatable to assess the local mechanical interaction of metal samples suitable for orthopaedic applications with the bone tissue. CoCrMo scaffolds made of 1000 μm pores cubic cells may allow for a smoother load transfer to the bone when used as constitutive material of orthopaedic implants.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Additive Manufacturing and 3D Printing Technologies · Additive Manufacturing Materials and Processes · Bone Tissue Engineering Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (48)

Show source-provided references
1. Measurement of apparent mechanical properties of trabecular bone tissue: accuracy and limitation of digital image correlation technique10.1016/j.jmbbm.2019.103542 ↗
2. Finite element study of functionally graded porous femoral stems incorporating body-centered cubic structure10.1111/aor.13444 ↗
3. Fully porous 3D printed titanium femoral stem to reduce stress-shielding following total hip arthroplasty10.1002/jor.23445 ↗
4. An international comparison of the estimated effect of the aging of the population on the major cause of disablement, musculoskeletal disorders
5. Influence of porosity on mechanical properties and in vivo response of Ti6Al4V implants10.1016/j.actbio.2009.11.011 ↗
6. Compression failure characterization of cancellous bone combining experimental testing, digital image correlation and finite element modeling10.1016/j.ijmecsci.2019.105213 ↗
7. The epidemiology of revision total knee arthroplasty in the United States10.1007/s11999-009-0945-0 ↗
8. CoCr porous scaffolds manufactured via selective laser melting in orthopedics: topographical, mechanical, and biological characterization10.1002/jbm.b.34328 ↗
9. Design and analysis of porous functionally graded femoral prostheses with improved stress shielding
10. In vitro stress shielding measurements can be affected by large errors10.1016/S0883-5403(99)90129-8 ↗
11. Contribution of obesity to the rise in incidence of rheumatoid arthritis10.1002/acr.21660 ↗
12. Extracting accurate strain measurements in bone mechanics: a critical review of current methods10.1016/j.jmbbm.2015.06.006 ↗
13. Continuous functionally graded porous titanium scaffolds manufactured by selective laser melting for bone implants10.1016/j.jmbbm.2018.01.013 ↗
14. Contemporary surgical indications and referral trends in revision total hip arthroplasty: a 10-year review10.1016/j.arth.2015.09.026 ↗
15. Evaluation of the stiffness characteristics of square pore CoCrMo cellular structures manufactured using laser melting technology for potential orthopaedic applications10.1016/j.matdes.2013.05.009 ↗
16. An investigation into the flexural characteristics of functionally graded cobalt chrome femoral stems manufactured using selective laser melting10.1016/j.matdes.2014.03.068 ↗
17. Stress shielding reduction via graded porosity of a femoral stem implant10.3139/120.111374 ↗
18. Digital image correlation techniques for strain measurement in a variety of biomechanical test models
19. Structural, mechanical and in vitro characterization of individually structured Ti–6Al–4V produced by direct laser forming10.1016/j.biomaterials.2005.07.041 ↗
20. The relationship between stress shielding and bone resorption around total hip stems and the effects of flexible materials
21. Current modes of failure in TKA: infection, instability, and stiffness predominate10.1007/s11999-014-3540-y ↗
22. Stiffness and strength tailoring of cobalt chromium graded cellular structures for stress-shielding reduction10.1016/j.matdes.2016.11.090 ↗
23. Fabrication of Co-Cr-Mo endoprosthetic ankle devices by means of Selective Laser Melting (SLM)10.1016/j.matdes.2016.05.083 ↗
24. Lattice structures and functionally graded materials applications in additive manufacturing of orthopedic implants: a review
25. Materials for hip prostheses: a review of wear and loading considerations10.3390/ma12030495 ↗
26. Bone mechanical properties in healthy and diseased States10.1146/annurev-bioeng-062117-121139 ↗
27. Stress shielding and bone resorption in shoulder arthroplasty10.1067/mse.2003.22 ↗
28. Elastic modulus varies along the bovine femur10.1016/j.jmbbm.2017.03.021 ↗
29. Design of new generation femoral prostheses using functionally graded materials: a finite element analysis10.1177/0954411912459421 ↗
30. Mechanical and in vitro biological properties of uniform and graded cobalt-chrome lattice structures in orthopedic implants10.1002/jbm.b.34857 ↗
31. The use of digital image correlation in the biomechanical area: a review10.1080/23335432.2015.1117395 ↗
32. Digital imaging techniques in experimental stress analysis10.1117/12.7972925 ↗
33. Defects-tolerant Co-Cr-Mo dental alloys prepared by selective laser melting10.1016/j.dental.2015.09.003 ↗
34. Why are total knee arthroplasties failing today-has anything changed after 10 years?10.1016/j.arth.2013.07.024 ↗
35. Development of a porous metallic femoral stem: design, manufacturing, simulation and mechanical testing10.1016/j.matdes.2016.10.064 ↗
36. Rates of total joint replacement in the United States: future projections to 2020-2040 using the national inpatient sample10.3899/jrheum.170990 ↗
37. Determinants of stress shielding: design versus materials versus interface10.1097/00003086-199201000-00020 ↗
38. Determination of displacements using an improved digital correlation method10.1016/0262-8856(83)90064-1 ↗
39. Using digital image correlation to determine bone surface strains during loading and after adaptation of the mouse tibia10.1016/j.jbiomech.2009.10.042 ↗
40. Mapping the strain distribution on the proximal femur with titanium and flexible-stemmed implants using digital image correlation10.1302/0301-620X.92B8.23553 ↗
41. CoCr alloy processed by Selective Laser Melting (SLM): effect of Laser Energy Density on microstructure, surface morphology, and hardness10.1016/j.jmapro.2020.01.052 ↗
42. The effect of pore geometry on the in vitro biological behavior of human periosteum-derived cells seeded on selective laser-melted Ti6Al4V bone scaffolds10.1016/j.actbio.2012.04.001 ↗
43. Study on the designing rules and processability of porous structure based on selective laser melting (SLM)10.1016/j.jmatprotec.2013.05.001 ↗
44. Das gesetz der Transformation der Knochen10.1055/s-0028-1144106 ↗
45. In vitro biocompatibility of Co-Cr alloy fabricated by selective laser melting or traditional casting techniques10.1016/j.matlet.2012.08.032 ↗
46. Ti-6Al-4V triply periodic minimal surface structures for bone implants fabricated via selective laser melting10.1016/j.jmbbm.2015.06.024 ↗
47. Applications of digital image correlation to biological tissues10.1117/1.1753270 ↗
48. Effects of scan line spacing on pore characteristics and mechanical properties of porous Ti6Al4V implants fabricated by selective laser melting10.1016/j.matdes.2014.05.021 ↗