Abstract

Ti-Nb-based alloys - with their superior mechanical properties and biocompatibility - are attractive biomaterials for orthopedic implants. By producing this alloys with a porous structure, it is possible to achieve mechanical properties similar to that of bone and to facilitate cellular activities. In this study, Ti16Nb (wt%) alloys containing porosity between 4.05-% and 60.79-% were produced by powder metallurgy using different amounts of space holder materials. The samples were sintered at 1200 °C for 3 h in a high-level vacuum. The effects of the space holder content - in terms of mechanical properties, amount and morphology of the pores, density and the corrosion behavior of the Ti16Nb alloy - were investigated. It is seen that the addition of 70 vol% space holder materials to the Ti16Nb alloy leads to a decrease in the density value from 4.67 g/cm3 to 1.91 g/cm3. Also, it is observed that by producing Ti16Nb with 70 vol% space holder, elastic modulus, compressive and transverse rupture strength values decreased from 96 GPa to 15 GPa, from 1450 MPa to 100 MPa, and from 1173 MPa to 97 MPa, respectively. Although Ti16Nb porous alloys are designed by imitating the properties of the cortical bone for use in the production of load-bearing implants, it is seen that increasing the amount of pores causes, an increase in the corrosion rate and the corrosion current density and a decrease in the polarization resistance.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Titanium Alloys Microstructure and Properties · Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (44)

Show source-provided references
1. Corrosion behaviour of porous Ti intended for biomedical applications10.1007/s10934-016-0185-0 ↗
2. Antunes, R.A., Oliveira, M.V. De, Costa, I., 2005. Investigation of the Corrosion Behavior of Porous Titanium in Hanks' Solution, In: Proceedings of the 10th International Latin American Conference on Powder Technology. Mangaratiba.
3. Fabrication of metallic biomedical scaffolds with the space holder method: a review10.3390/ma7053588 ↗
4. Shape-memory NiTi foams produced by replication of NaCl space-holders10.1016/j.actbio.2008.06.005 ↗
5. The importance of particle size in porous titanium and nonporous counterparts for surface energy and its impact on apatite formation10.1016/j.actbio.2009.02.027 ↗
6. Highly porous titanium scaffolds for orthopaedic applications10.1002/jbm.b.31682 ↗
7. Study of the porous Ti35Nb alloy processing parameters for implant applications10.1016/j.powtec.2015.03.014 ↗
8. Porous titanium and Ti–35Nb alloy: effects on gene expression of osteoblastic cells derived from human alveolar bone10.1007/s10856-015-5594-0 ↗
9. Processing of titanium foams using magnesium spacer particles10.1016/j.scriptamat.2006.11.010 ↗
10. Corrosion behaviour of porous Ti-39Nb alloy for biomedical applications10.1016/j.corsci.2013.03.007 ↗
11. Ti based biomaterials, the ultimate choice for orthopaedic implants – A review10.1016/j.pmatsci.2008.06.004 ↗
12. German · 1996
13. Investigation of passivation and galvanic corrosion of Ti-Nb alloys and pure titanium10.1002/maco.201407784 ↗
14. Investigation of passivation and galvanic corrosion of Ti-Nb alloys and pure titanium
15. Titanium foam made with saccharose as a space holder10.1007/s10934-013-9696-0 ↗
16. Fabrication and Shape Memory Characteristics of Highly Porous Ti-Nb-Mo Biomaterials10.1515/amm-2017-0210 ↗
17. How useful is SBF in predicting in vivo bone bioactivity?10.1016/j.biomaterials.2006.01.017 ↗
18. Porous titanium by electro‐chemical dissolution of steel space‐holders10.1002/adem.200800072 ↗
19. Surface microstructures and corrosion resistance of Ni-Ti-Nb shape memory thin films10.1016/j.apsusc.2017.04.070 ↗
20. The influence of porosity on corrosion characteristics of porous NiTi alloy in simulated body fluid10.1016/S0167-577X(02)00809-1 ↗
21. Biomedical porous TiNbZrFe alloys fabricated using NH 4 HCO 3 as pore forming agent through powder metallurgy route10.1179/1743290115Y.0000000005 ↗
22. Microstructure, mechanical behavior and biocompatibility of powder metallurgy Nb-Ti-Ta alloys as biomedical material10.1016/j.msec.2016.10.043 ↗
23. Processing titanium foams using tapioca starch as a space holder10.1016/j.jmatprotec.2011.08.008 ↗
24. Zr-Ti-Nb porous alloys for biomedical application10.1016/j.msec.2011.10.035 ↗
25. Effects of Sn addition on the microstructure, mechanical properties and corrosion behavior of Ti–Nb–Sn alloys10.1016/j.matchar.2014.08.014 ↗
26. Acoustical and poromechanical characterisation of titanium scaffolds for biomedical applications10.1111/j.1475-1305.2007.00360.x ↗
27. Nakajima · 2013
28. Mechanical properties and microstructure of powder metallurgy Ti-xNb-yMo alloys for implant materials10.1016/j.matdes.2015.09.106 ↗
29. Microstructures and mechanical properties of porous titanium compacts prepared by powder sintering10.2320/matertrans.43.443 ↗
30. Phase composition, microstructure, and mechanical properties of porous Ti-Nb-Zr alloys prepared by a two-step foaming powder metallurgy method10.1016/j.jmbbm.2014.02.001 ↗
31. In vitro corrosion behaviour of Ti-Nb-Sn shape memory alloys in Ringer's physiological solution10.1007/s10856-012-4560-3 ↗
32. Porous titanium scaffolds fabricated using a rapid prototyping and powder metallurgy technique10.1016/j.biomaterials.2008.05.032 ↗
33. Design of controlled-release drug delivery systems
34. Titanium foams for biomedical applications: a review10.1179/175355510X12744412709403 ↗
35. The effect of pore size and porosity on mechanical properties and biological response of porous titanium scaffolds10.1016/j.msec.2017.03.249 ↗
36. Electrochemical corrosion behavior of biomedical Ti–22Nb and Ti–22Nb–6Zr alloys in saline medium10.1002/maco.200805173 ↗
37. Processing of biocompatible porous Ti and Mg10.1016/S1359-6462(01)01132-0 ↗
38. Influence of pore characteristics on microstructure, mechanical properties and corrosion resistance of selective laser sintered porous Ti-Mo alloys for biomedical applications10.1016/j.electacta.2013.04.105 ↗
39. Mechanical properties and bioactive surface modification via alkali-heat treatment of a porous Ti-18Nb-4Sn alloy for biomedical applications10.1016/j.actbio.2008.04.022 ↗
40. Metallurgical properties and biomimetic HA deposition performance of Ti-Nb PIM alloys10.1016/j.jallcom.2018.02.274 ↗
41. Assessment of Ti–16Nb–xZr alloys produced via PIM for implant applications
42. Characterization of biomedical Ti-16Nb-(0–4)Sn alloys produced by powder injection molding10.1016/j.vacuum.2017.05.018 ↗
43. Effects of Nb content on the microstructural and mechanical properties of the biomedical PM Ti-Nb alloys10.5505/pajes.2017.26539 ↗
44. Yılmaz, E., Gökçe, A., Fındık, F., Gülsoy, H.Ö., 2017. Electrochemical Corrosion Behavior of Ti and Ti-16Nb Alloy for Implant Applications. In: Özdemir, N., Esen, H. (Eds.), Proceedings of the 8th International Advanced Technologies Symposium (IATS’17). Elazığ, pp. 2244–2251.