Optical coherence elastography assessment of corneal viscoelasticity with a modified Rayleigh-Lamb wave model
Source abstract
Abstract
The biomechanical properties of the cornea play a critical role in forming vision. Diseases such as keratoconus can structurally degenerate the cornea causing a pathological loss in visual acuity. UV-A/riboflavin corneal collagen crosslinking (CXL) is a clinically available treatment to stiffen the cornea and restore its healthy shape and function. However, current CXL techniques do not account for pre-existing biomechanical properties of the cornea nor the effects of the CXL treatment itself. In addition to the inherent corneal structure, the intraocular pressure (IOP) can also dramatically affect the measured biomechanical properties of the cornea. In this work, we present the details and development of a modified Rayleigh-Lamb frequency equation model for quantifying corneal biomechanical properties. After comparison with finite element modeling, the model was utilized to quantify the viscoelasticity of in situ porcine corneas in the whole eye-globe configuration before and after CXL based on noncontact optical coherence elastography measurements. Moreover, the viscoelasticity of the untreated and CXL-treated eyes was quantified at various IOPs. The results showed that the stiffness of the cornea increased after CXL and that corneal stiffness is close to linear as a function of IOP. These results show that the modified Rayleigh-Lamb wave model can provide an accurate assessment of corneal viscoelasticity, which could be used for customized CXL therapies.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Corneal surgery and disorders · Corneal Surgery and Treatments · Glaucoma and retinal disorders
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (82)
Show source-provided references
1. Achenbach · 2012
2. Breast elasticity imaging
3. Corneal-thickness spatial profile and corneal-volume distribution: tomographic indices to detect keratoconus10.1016/j.jcrs.2006.06.025 ↗
4. Thyroid nodules and shear wave elastography: a new tool in thyroid cancer detection10.1016/j.ultrasmedbio.2015.06.021 ↗
5. Dynamic Scheimpflug-based assessment of keratoconus and the effects of corneal cross-linking10.3928/1081597X-20140513-02 ↗
6. Evaluation of the relationship of corneal biomechanical metrics with physical intraocular pressure and central corneal thickness in ex vivo rabbit eye globes10.1016/j.exer.2015.05.018 ↗
7. Biomechanical changes of collagen cross-linking on human keratoconic corneas using scanning acoustic microscopy
8. Constitutive laws for biomechanical modeling of refractive surgery10.1115/1.2796033 ↗
9. Collagen cross-linking using rose bengal and green light to increase corneal stiffness10.1167/iovs.12-11509 ↗
10. Corneal stromal elasticity and viscoelasticity assessed by atomic force microscopy after different cross linking protocols10.1016/j.exer.2015.06.015 ↗
11. Mechanical anisotropy of porcine cornea and correlation with stromal microstructure10.1016/j.exer.2009.01.010 ↗
12. Biomechanical properties of human and porcine corneas10.1016/j.exer.2008.02.006 ↗
13. Comparative study of corneal strip extensometry and inflation tests10.1098/rsif.2005.0034 ↗
14. Experimental assessment of corneal anisotropy10.3928/1081597X-20080201-09 ↗
15. The journey of elastography: background, current status, and future possibilities in breast cancer diagnosis10.1016/j.clbc.2015.01.002 ↗
16. Method for optical coherence elastography of the cornea10.1117/1.3526701 ↗
17. Serial biomechanical comparison of edematous, normal, and collagen crosslinked human donor corneas using optical coherence elastography10.1016/j.jcrs.2014.03.017 ↗
18. Evaluation of corneal hysteresis and corneal resistance factor after corneal cross-linking for keratoconus10.1007/s00417-011-1897-0 ↗
19. Can we measure corneal biomechanical changes after collagen cross-linking in eyes with keratoconus?--a pilot study10.1097/ICO.0b013e318190734d ↗
20. Permanent visual loss in eyes with keratoconus10.1111/aos.12253 ↗
21. In vivo biomechanical changes after corneal collagen cross-linking for keratoconus and corneal ectasia: 1-year analysis of a randomized, controlled, clinical trial10.1097/ICO.0b013e31821eea66 ↗
22. Quantitative assessment of corneal viscoelasticity using optical coherence elastography and a modified Rayleigh-Lamb equation10.1117/1.JBO.20.2.020501 ↗
23. Analysis of the effects of curvature and thickness on elastic wave velocity in cornea-like structures by finite element modeling and optical coherence elastography10.1063/1.4922728 ↗
24. Quantitative methods for reconstructing tissue biomechanical properties in optical coherence elastography: a comparison study10.1088/0031-9155/60/9/3531 ↗
25. Air puff induced corneal vibrations: theoretical simulations and clinical observations10.3928/1081597X-20140212-02 ↗
26. Analysis of the effect of the fluid-structure interface on elastic wave velocity in cornea-like structures by OCE and FEM10.1088/1612-2011/13/3/035602 ↗
27. The thickness-hydration relationship of the cornea10.1016/S0014-4835(66)80010-6 ↗
28. Strip extensiometry for comparison of the mechanical response of bovine, rabbit, and human corneas10.1115/1.2891373 ↗
29. Optical coherence tomography10.1126/science.1957169 ↗
30. Ultraviolet A/riboflavin corneal cross-linking for infectious keratitis associated with corneal melts10.1097/ICO.0b013e318169d698 ↗
31. Thermal and biomechanical parameters of porcine cornea10.1097/00003226-200005000-00020 ↗
32. Corneal biomechanical changes after collagen cross-linking from porcine eye inflation experiments10.1167/iovs.09-4536 ↗
33. Differentiating untreated and cross-linked porcine corneas of the same measured stiffness with optical coherence elastography10.1117/1.JBO.19.11.110502 ↗
34. Dynamic optical coherence tomography measurements of elastic wave propagation in tissue-mimicking phantoms and mouse cornea in vivo10.1117/1.JBO.18.12.121503 ↗
35. Air-pulse OCE for assessment of age-related changes in mouse cornea in vivo10.1088/1612-2011/11/6/065601 ↗
36. Corneal stiffness affects IOP elevation during rapid volume change in the eye10.1167/iovs.08-2365 ↗
37. Influence of corneal biomechanical properties on intraocular pressure measurement: quantitative analysis10.1016/j.jcrs.2004.09.031 ↗
38. Development of phase-stabilized swept-source OCT for the ultrasensitive quantification of microbubbles10.1134/S1054660X08090144 ↗
39. Phase-sensitive swept source optical coherence tomography for imaging and quantifying of microbubbles in clear and scattering media10.1063/1.3116614 ↗
40. Corneal power correction factor for photorefractive keratectomy10.3928/1081-597X-19940301-11 ↗
41. Pulsed vs continuous light accelerated corneal collagen crosslinking: in vivo qualitative investigation by confocal microscopy and corneal OCT10.1038/eye.2014.163 ↗
42. Evaluation of the influence of corneal biomechanical properties on intraocular pressure measurements using the ocular response analyzer10.1097/01.ijg.0000212268.42606.97 ↗
43. Measurement of corneal elasticity with an acoustic radiation force elasticity microscope10.1016/j.ultrasmedbio.2013.11.009 ↗
44. Magnetic resonance elastography by direct visualization of propagating acoustic strain waves10.1126/science.7569924 ↗
45. On Lamb and Rayleigh wave convergence in viscoelastic tissues10.1088/0031-9155/56/20/014 ↗
46. Lamb wave dispersion ultrasound vibrometry (LDUV) method for quantifying mechanical properties of viscoelastic solids10.1088/0031-9155/56/7/021 ↗
47. Conventional versus accelerated corneal collagen cross-linking in the treatment of keratoconus10.1111/ceo.12571 ↗
48. In vivo evidence of porcine cornea anisotropy using supersonic shear wave imaging10.1167/iovs.14-15127 ↗
49. Monitoring of cornea elastic properties changes during UV-A/riboflavin-induced corneal collagen cross-linking using supersonic shear wave imaging: a pilot study10.1167/iovs.11-9142 ↗
50. Elastography: a quantitative method for imaging the elasticity of biological tissues10.1177/016173469101300201 ↗
51. Determination of the true intraocular pressure and modulus of elasticity of the human cornea in vivo10.1006/bulm.1999.0102 ↗
52. The influence of the refractive correction on the vision-related quality of life in keratoconus patients
53. Spatially heterogeneous corneal mechanical responses before and after riboflavin-ultraviolet-A crosslinking10.1016/j.jcrs.2013.09.022 ↗
54. Computational modeling of mechanical anisotropy in the cornea and sclera10.1016/j.jcrs.2004.10.048 ↗
55. Acoustic radiation force optical coherence elastography of corneal tissue10.1109/JSTQE.2016.2524618 ↗
56. Corneal cross-linking10.1016/j.survophthal.2015.04.002 ↗
57. Corneal collagen cross-linking for ectasia after LASIK and photorefractive keratectomy: long-term results10.1016/j.ophtha.2012.12.027 ↗
58. Factors influencing corneal deformation and estimation of intraocular pressure
59. Intraoperative corneal thickness change and clinical outcomes after corneal collagen crosslinking: standard crosslinking versus hypotonic riboflavin10.1016/j.jcrs.2016.01.040 ↗
60. Corneal biomechanics and biomaterials10.1146/annurev-bioeng-070909-105243 ↗
61. Impact of keratoconus in the better eye and the worse eye on vision-related quality of life10.1167/iovs.13-12929 ↗
62. Brillouin microscopy of collagen crosslinking: noncontact depth-dependent analysis of corneal elastic modulus10.1167/iovs.12-11387 ↗
63. Brillouin optical microscopy for corneal biomechanics10.1167/iovs.11-8281 ↗
64. OCT elastography: imaging microscopic deformation and strain of tissue10.1364/OE.3.000199 ↗
65. Distribution of Young's modulus in porcine corneas after riboflavin/UVA-induced collagen cross-linking as measured by atomic force microscopy10.1371/journal.pone.0088186 ↗
66. Customized corneal cross-linking: one-year results10.1016/j.ajo.2016.02.029 ↗
67. Evaluating the effects of riboflavin/UV-A and rose-bengal/green light cross-linking of the rabbit cornea by noncontact optical coherence elastography
68. Investigating elastic anisotropy of the porcine cornea as a function of intraocular pressure with optical coherence elastography10.3928/1081597X-20160520-01 ↗
69. Noncontact elastic wave imaging optical coherence elastography for evaluating changes in corneal elasticity due to crosslinking10.1109/JQE.2016.2585338 ↗
70. Phase-sensitive optical coherence elastography at 1.5 million A-Lines per second10.1364/OL.40.002588 ↗
71. Quantitative differential phase measurement and imaging in transparent and turbid media by optical coherence tomography10.1364/OL.26.000518 ↗
72. Corneal hysteresis with intraocular pressure of a wide range: a test on porcine eyes10.3928/1081597X-20131115-05 ↗
73. Spatial characterization of corneal biomechanical properties with optical coherence elastography after UV cross-linking10.1364/BOE.5.001419 ↗
74. Magnetic resonance elastography of liver: technique, analysis, and clinical applications10.1002/jmri.23731 ↗
75. Noncontact depth-resolved micro-scale optical coherence elastography of the cornea10.1364/BOE.5.003807 ↗
76. Shear wave imaging optical coherence tomography (SWI-OCT) for ocular tissue biomechanics10.1364/OL.39.000041 ↗
77. Optical coherence elastography for tissue characterization: a review10.1002/jbio.201400108 ↗
78. A focused air-pulse system for optical-coherence-tomography-based measurements of tissue elasticity10.1088/1612-2011/10/7/075605 ↗
79. Riboflavin/ultraviolet-a-induced collagen crosslinking for the treatment of keratoconus10.1016/S0002-9394(02)02220-1 ↗
80. Stress-strain measurements of human and porcine corneas after riboflavin-ultraviolet-A-induced cross-linking10.1016/S0886-3350(03)00407-3 ↗
81. A comparison of biomechanical properties between human and porcine cornea10.1016/S0021-9290(00)00219-0 ↗
82. A review of collagen cross-linking in cornea and sclera10.1155/2015/289467 ↗